fond
Model Checking Contest 2024
14th edition, Geneva, Switzerland, June 25, 2024
Execution of r049-tajo-171620400400257
Last Updated
July 7, 2024

About the Execution of LoLA for BridgeAndVehicles-PT-V50P50N20

Execution Summary
Max Memory
Used (MB)
Time wait (ms) CPU Usage (ms) I/O Wait (ms) Computed Result Execution
Status
15889.516 3600000.00 1994619.00 743.80 TT???T?????T?FFT normal

Execution Chart

We display below the execution chart for this examination (boot time has been removed).

Trace from the execution

Formatting '/mnt/tpsp/fkordon/mcc2024-input.r049-tajo-171620400400257.qcow2', fmt=qcow2 size=4294967296 backing_file='/mnt/tpsp/fkordon/mcc2024-input.qcow2' backing_fmt='qcow2' encryption=off cluster_size=65536 lazy_refcounts=off
Waiting for the VM to be ready (probing ssh)
..............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
=====================================================================
Generated by BenchKit 2-5568
Executing tool lola
Input is BridgeAndVehicles-PT-V50P50N20, examination is CTLCardinality
Time confinement is 3600 seconds
Memory confinement is 16384 MBytes
Number of cores is 4
Run identifier is r049-tajo-171620400400257
=====================================================================

--------------------
preparation of the directory to be used:
/home/mcc/execution
total 8.1M
-rw-r--r-- 1 mcc users 19K Apr 13 02:10 CTLCardinality.txt
-rw-r--r-- 1 mcc users 105K Apr 13 02:10 CTLCardinality.xml
-rw-r--r-- 1 mcc users 72K Apr 13 02:05 CTLFireability.txt
-rw-r--r-- 1 mcc users 298K Apr 13 02:05 CTLFireability.xml
-rw-r--r-- 1 mcc users 4.2K May 18 16:42 GenericPropertiesDefinition.xml
-rw-r--r-- 1 mcc users 6.4K May 18 16:42 GenericPropertiesVerdict.xml
-rw-r--r-- 1 mcc users 17K Apr 22 14:30 LTLCardinality.txt
-rw-r--r-- 1 mcc users 65K Apr 22 14:30 LTLCardinality.xml
-rw-r--r-- 1 mcc users 65K Apr 22 14:30 LTLFireability.txt
-rw-r--r-- 1 mcc users 209K Apr 22 14:30 LTLFireability.xml
-rw-r--r-- 1 mcc users 26K Apr 13 03:23 ReachabilityCardinality.txt
-rw-r--r-- 1 mcc users 157K Apr 13 03:23 ReachabilityCardinality.xml
-rw-r--r-- 1 mcc users 1.1M Apr 13 03:19 ReachabilityFireability.txt
-rw-r--r-- 1 mcc users 4.0M Apr 13 03:19 ReachabilityFireability.xml
-rw-r--r-- 1 mcc users 3.7K Apr 22 14:30 UpperBounds.txt
-rw-r--r-- 1 mcc users 7.8K Apr 22 14:30 UpperBounds.xml
-rw-r--r-- 1 mcc users 5 May 18 16:42 equiv_col
-rw-r--r-- 1 mcc users 10 May 18 16:42 instance
-rw-r--r-- 1 mcc users 6 May 18 16:42 iscolored
-rw-r--r-- 1 mcc users 2.0M May 18 16:42 model.pnml

--------------------
content from stdout:

=== Data for post analysis generated by BenchKit (invocation template)

The expected result is a vector of booleans
BOOL_VECTOR

here is the order used to build the result vector(from text file)
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14
FORMULA_NAME BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15

=== Now, execution of the tool begins

BK_START 1717012779673

FORMULA BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01 TRUE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05 TRUE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11 TRUE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15 TRUE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00 TRUE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT

BK_TIME_CONFINEMENT_REACHED

--------------------
content from stderr:

[lola][I] LoLA will run for 3600 seconds at most (--timelimit)
[lola][W] unknown unit in memory specification: using default
[lola][I] MEM LIMIT 5
[lola][I] NET
[lola][I] reading net from model.pnml
[lola][I] input: PNML file (--pnmlnet)
[lola][I] reading pnml
[lola][I] PNML file contains place/transition net
[lola][I] closed net file model.pnml
[lola][I] finished parsing
[lola][I] Reading formula.
[lola][I] Using XML format (--xmlformula)
[lola][I] reading XML formula
[lola][I] reading formula from CTLCardinality.xml
[lola][I] Rule S: 0 transitions removed,0 places removed
[lola][I] LAUNCH task # 4 (type CNST) for 3 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01
[lola][I] time limit : 0 sec
[lola][I] memory limit: 0 pages
[lola][I] LAUNCH task # 16 (type CNST) for 15 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05
[lola][I] time limit : 0 sec
[lola][I] memory limit: 0 pages
[lola][I] LAUNCH task # 51 (type CNST) for 50 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14
[lola][I] time limit : 0 sec
[lola][I] memory limit: 0 pages
[lola][I] FINISHED task # 51 (type CNST) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14
[lola][I] result : false
[lola][I] FINISHED task # 16 (type CNST) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05
[lola][I] result : true
[lola][I] FINISHED task # 4 (type CNST) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01
[lola][I] result : true
[lola][I] LAUNCH task # 42 (type CNST) for 41 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11
[lola][I] time limit : 0 sec
[lola][I] memory limit: 0 pages
[lola][I] FINISHED task # 42 (type CNST) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11
[lola][I] result : true
[lola][I] LAUNCH task # 54 (type CNST) for 53 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15
[lola][I] time limit : 0 sec
[lola][I] memory limit: 0 pages
[lola][I] FINISHED task # 54 (type CNST) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15
[lola][I] result : true
[lola][I] LAUNCH task # 1 (type CNST) for 0 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00
[lola][I] time limit : 0 sec
[lola][I] memory limit: 0 pages
[lola][I] FINISHED task # 1 (type CNST) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00
[lola][I] result : true
[lola][I] LAUNCH task # 48 (type EXCL) for 47 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13
[lola][I] time limit : 299 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 48 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13
[lola][I] result : false
[lola][I] markings : 413
[lola][I] fired transitions : 412
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I] LAUNCH task # 13 (type EXCL) for 12 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04
[lola][I] time limit : 326 sec
[lola][I] memory limit: 2000 pages
[lola][I] LAUNCH task # 60 (type EQUN) for 18 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06
[lola][I] time limit : 32000000 sec
[lola][I] memory limit: 5 pages
[lola][I] FINISHED task # 60 (type EQUN) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06
[lola][I] result : unknown
[lola][I] LAUNCH task # 64 (type EQUN) for 18 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06
[lola][I] time limit : 32000000 sec
[lola][I] memory limit: 5 pages
[lola][I] FINISHED task # 64 (type EQUN) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06
[lola][I] result : unknown
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 2/326 2/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 262097 m, 52419 m/sec, 686285 t fired, .
[lola][.]
[lola][.] Time elapsed: 10 secs. Pages in use: 2
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 7/326 5/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 835416 m, 114663 m/sec, 2493095 t fired, .
[lola][.]
[lola][.] Time elapsed: 15 secs. Pages in use: 5
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 12/326 7/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 1327966 m, 98510 m/sec, 4147709 t fired, .
[lola][.]
[lola][.] Time elapsed: 20 secs. Pages in use: 7
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 17/326 10/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 1839655 m, 102337 m/sec, 5906767 t fired, .
[lola][.]
[lola][.] Time elapsed: 25 secs. Pages in use: 10
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 22/326 12/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 2236933 m, 79455 m/sec, 7280426 t fired, .
[lola][.]
[lola][.] Time elapsed: 30 secs. Pages in use: 12
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 27/326 14/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 2712641 m, 95141 m/sec, 8952686 t fired, .
[lola][.]
[lola][.] Time elapsed: 35 secs. Pages in use: 14
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 32/326 17/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 3208783 m, 99228 m/sec, 10668808 t fired, .
[lola][.]
[lola][.] Time elapsed: 40 secs. Pages in use: 17
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 37/326 19/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 3766720 m, 111587 m/sec, 12649453 t fired, .
[lola][.]
[lola][.] Time elapsed: 45 secs. Pages in use: 19
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 42/326 22/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 4285550 m, 103766 m/sec, 14453562 t fired, .
[lola][.]
[lola][.] Time elapsed: 50 secs. Pages in use: 22
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 47/326 24/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 4774762 m, 97842 m/sec, 16195727 t fired, .
[lola][.]
[lola][.] Time elapsed: 55 secs. Pages in use: 24
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 52/326 27/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 5241618 m, 93371 m/sec, 17865713 t fired, .
[lola][.]
[lola][.] Time elapsed: 60 secs. Pages in use: 27
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 57/326 29/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 5675988 m, 86874 m/sec, 19370594 t fired, .
[lola][.]
[lola][.] Time elapsed: 65 secs. Pages in use: 29
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 62/326 31/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 6145181 m, 93838 m/sec, 21050397 t fired, .
[lola][.]
[lola][.] Time elapsed: 70 secs. Pages in use: 31
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 67/326 34/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 6705508 m, 112065 m/sec, 23066077 t fired, .
[lola][.]
[lola][.] Time elapsed: 75 secs. Pages in use: 34
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 72/326 37/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 7222589 m, 103416 m/sec, 24873136 t fired, .
[lola][.]
[lola][.] Time elapsed: 80 secs. Pages in use: 37
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 77/326 39/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 7738807 m, 103243 m/sec, 26709612 t fired, .
[lola][.]
[lola][.] Time elapsed: 85 secs. Pages in use: 39
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 82/326 42/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 8255096 m, 103257 m/sec, 28574946 t fired, .
[lola][.]
[lola][.] Time elapsed: 90 secs. Pages in use: 42
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 87/326 45/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 8808174 m, 110615 m/sec, 30551530 t fired, .
[lola][.]
[lola][.] Time elapsed: 95 secs. Pages in use: 45
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 92/326 47/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 9288395 m, 96044 m/sec, 32229309 t fired, .
[lola][.]
[lola][.] Time elapsed: 100 secs. Pages in use: 47
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 97/326 50/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 9805298 m, 103380 m/sec, 34091042 t fired, .
[lola][.]
[lola][.] Time elapsed: 105 secs. Pages in use: 50
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 102/326 52/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 10364227 m, 111785 m/sec, 36112141 t fired, .
[lola][.]
[lola][.] Time elapsed: 110 secs. Pages in use: 52
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 107/326 55/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 10909617 m, 109078 m/sec, 38042284 t fired, .
[lola][.]
[lola][.] Time elapsed: 115 secs. Pages in use: 55
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 112/326 57/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 11394314 m, 96939 m/sec, 39750452 t fired, .
[lola][.]
[lola][.] Time elapsed: 120 secs. Pages in use: 57
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 117/326 60/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 11923292 m, 105795 m/sec, 41651949 t fired, .
[lola][.]
[lola][.] Time elapsed: 125 secs. Pages in use: 60
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 122/326 63/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 12468662 m, 109074 m/sec, 43623035 t fired, .
[lola][.]
[lola][.] Time elapsed: 130 secs. Pages in use: 63
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 127/326 66/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 13036266 m, 113520 m/sec, 45695699 t fired, .
[lola][.]
[lola][.] Time elapsed: 135 secs. Pages in use: 66
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 132/326 68/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 13525591 m, 97865 m/sec, 47402637 t fired, .
[lola][.]
[lola][.] Time elapsed: 140 secs. Pages in use: 68
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 137/326 71/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 14020799 m, 99041 m/sec, 49092000 t fired, .
[lola][.]
[lola][.] Time elapsed: 145 secs. Pages in use: 71
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 142/326 73/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 14536458 m, 103131 m/sec, 50963003 t fired, .
[lola][.]
[lola][.] Time elapsed: 150 secs. Pages in use: 73
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 147/326 76/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 15078540 m, 108416 m/sec, 52905685 t fired, .
[lola][.]
[lola][.] Time elapsed: 155 secs. Pages in use: 76
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 152/326 79/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 15618776 m, 108047 m/sec, 54859558 t fired, .
[lola][.]
[lola][.] Time elapsed: 160 secs. Pages in use: 79
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 157/326 81/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 16163643 m, 108973 m/sec, 56763853 t fired, .
[lola][.]
[lola][.] Time elapsed: 165 secs. Pages in use: 81
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 162/326 84/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 16648387 m, 96948 m/sec, 58442975 t fired, .
[lola][.]
[lola][.] Time elapsed: 170 secs. Pages in use: 84
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 167/326 86/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 17165494 m, 103421 m/sec, 60331298 t fired, .
[lola][.]
[lola][.] Time elapsed: 175 secs. Pages in use: 86
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 172/326 89/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 17702745 m, 107450 m/sec, 62247755 t fired, .
[lola][.]
[lola][.] Time elapsed: 180 secs. Pages in use: 89
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 177/326 92/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 18241965 m, 107844 m/sec, 64224089 t fired, .
[lola][.]
[lola][.] Time elapsed: 185 secs. Pages in use: 92
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 182/326 94/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 18789569 m, 109520 m/sec, 66175584 t fired, .
[lola][.]
[lola][.] Time elapsed: 190 secs. Pages in use: 94
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 187/326 97/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 19287907 m, 99667 m/sec, 67842785 t fired, .
[lola][.]
[lola][.] Time elapsed: 195 secs. Pages in use: 97
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 192/326 100/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 19789554 m, 100329 m/sec, 69659737 t fired, .
[lola][.]
[lola][.] Time elapsed: 200 secs. Pages in use: 100
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 197/326 102/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 20328974 m, 107884 m/sec, 71611776 t fired, .
[lola][.]
[lola][.] Time elapsed: 205 secs. Pages in use: 102
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 202/326 105/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 20871111 m, 108427 m/sec, 73565148 t fired, .
[lola][.]
[lola][.] Time elapsed: 210 secs. Pages in use: 105
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 207/326 108/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 21405711 m, 106920 m/sec, 75519418 t fired, .
[lola][.]
[lola][.] Time elapsed: 215 secs. Pages in use: 108
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 212/326 110/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 21951106 m, 109079 m/sec, 77359922 t fired, .
[lola][.]
[lola][.] Time elapsed: 220 secs. Pages in use: 110
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 217/326 113/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 22433656 m, 96510 m/sec, 79050078 t fired, .
[lola][.]
[lola][.] Time elapsed: 225 secs. Pages in use: 113
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 222/326 115/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 22938084 m, 100885 m/sec, 80889145 t fired, .
[lola][.]
[lola][.] Time elapsed: 230 secs. Pages in use: 115
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 227/326 118/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 23473111 m, 107005 m/sec, 82817729 t fired, .
[lola][.]
[lola][.] Time elapsed: 235 secs. Pages in use: 118
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 232/326 121/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 24021242 m, 109626 m/sec, 84789214 t fired, .
[lola][.]
[lola][.] Time elapsed: 240 secs. Pages in use: 121
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 237/326 123/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 24558712 m, 107494 m/sec, 86751170 t fired, .
[lola][.]
[lola][.] Time elapsed: 245 secs. Pages in use: 123
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 242/326 126/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 25094627 m, 107183 m/sec, 88607096 t fired, .
[lola][.]
[lola][.] Time elapsed: 250 secs. Pages in use: 126
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 247/326 129/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 25584847 m, 98044 m/sec, 90260585 t fired, .
[lola][.]
[lola][.] Time elapsed: 255 secs. Pages in use: 129
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 252/326 131/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 26078549 m, 98740 m/sec, 92041666 t fired, .
[lola][.]
[lola][.] Time elapsed: 260 secs. Pages in use: 131
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 257/326 134/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 26607737 m, 105837 m/sec, 93966928 t fired, .
[lola][.]
[lola][.] Time elapsed: 265 secs. Pages in use: 134
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 262/326 136/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 27155731 m, 109598 m/sec, 95932546 t fired, .
[lola][.]
[lola][.] Time elapsed: 270 secs. Pages in use: 136
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 267/326 139/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 27694135 m, 107680 m/sec, 97895200 t fired, .
[lola][.]
[lola][.] Time elapsed: 275 secs. Pages in use: 139
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 272/326 142/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 28233684 m, 107909 m/sec, 99857670 t fired, .
[lola][.]
[lola][.] Time elapsed: 280 secs. Pages in use: 142
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 277/326 144/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 28753739 m, 104011 m/sec, 101528925 t fired, .
[lola][.]
[lola][.] Time elapsed: 285 secs. Pages in use: 144
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 282/326 147/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 29227537 m, 94759 m/sec, 103225747 t fired, .
[lola][.]
[lola][.] Time elapsed: 290 secs. Pages in use: 147
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 287/326 149/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 29739291 m, 102350 m/sec, 105082594 t fired, .
[lola][.]
[lola][.] Time elapsed: 295 secs. Pages in use: 149
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 292/326 152/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 30271154 m, 106372 m/sec, 106983623 t fired, .
[lola][.]
[lola][.] Time elapsed: 300 secs. Pages in use: 152
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 297/326 155/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 30804420 m, 106653 m/sec, 108926312 t fired, .
[lola][.]
[lola][.] Time elapsed: 305 secs. Pages in use: 155
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 302/326 157/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 31335771 m, 106270 m/sec, 110855887 t fired, .
[lola][.]
[lola][.] Time elapsed: 310 secs. Pages in use: 157
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 307/326 160/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 31872521 m, 107350 m/sec, 112801035 t fired, .
[lola][.]
[lola][.] Time elapsed: 315 secs. Pages in use: 160
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 312/326 163/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 32399003 m, 105296 m/sec, 114497414 t fired, .
[lola][.]
[lola][.] Time elapsed: 320 secs. Pages in use: 163
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 317/326 165/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 32866115 m, 93422 m/sec, 116136309 t fired, .
[lola][.]
[lola][.] Time elapsed: 325 secs. Pages in use: 165
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 322/326 168/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 33361195 m, 99016 m/sec, 117927668 t fired, .
[lola][.]
[lola][.] Time elapsed: 330 secs. Pages in use: 168
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][W] CANCELED task # 13 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 (local timeout)
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 1 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 335 secs. Pages in use: 170
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] LAUNCH task # 45 (type EXCL) for 44 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12
[lola][I] time limit : 326 sec
[lola][I] memory limit: 2000 pages
[lola][I] LAUNCH task # 13 (type EXCL) for 12 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04
[lola][I] time limit : 3265 sec
[lola][I] memory limit: 5 pages
[lola][I] FINISHED task # 45 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12
[lola][I] result : false
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 13 CTL EXCL 5/326 3/5 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 521789 m, -6567881 m/sec, 1450011 t fired, .
[lola][.]
[lola][.] Time elapsed: 340 secs. Pages in use: 173
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] CANCELED task # 13 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04 (memory limit exceeded)
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 3 0 0 5 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 345 secs. Pages in use: 175
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] LAUNCH task # 39 (type EXCL) for 38 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10
[lola][I] time limit : 361 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 39 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10
[lola][I] result : false
[lola][I] markings : 553
[lola][I] fired transitions : 552
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I] LAUNCH task # 36 (type EXCL) for 35 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09
[lola][I] time limit : 406 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 36 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09
[lola][I] result : false
[lola][I] markings : 440
[lola][I] fired transitions : 854
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I] LAUNCH task # 33 (type EXCL) for 32 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08
[lola][I] time limit : 465 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 33 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08
[lola][I] result : false
[lola][I] markings : 493
[lola][I] fired transitions : 1734
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I] LAUNCH task # 30 (type EXCL) for 29 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07
[lola][I] time limit : 542 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 30 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07
[lola][I] result : true
[lola][I] markings : 101
[lola][I] fired transitions : 100
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I] LAUNCH task # 25 (type EXCL) for 18 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06
[lola][I] time limit : 651 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 25 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06
[lola][I] result : false
[lola][I] markings : 1
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I] LAUNCH task # 10 (type EXCL) for 9 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03
[lola][I] time limit : 813 sec
[lola][I] memory limit: 2000 pages
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 5/813 3/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 456056 m, 91211 m/sec, 1398412 t fired, .
[lola][.]
[lola][.] Time elapsed: 350 secs. Pages in use: 175
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 10/813 5/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 963155 m, 101419 m/sec, 3039959 t fired, .
[lola][.]
[lola][.] Time elapsed: 355 secs. Pages in use: 175
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 15/813 8/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 1461698 m, 99708 m/sec, 4664829 t fired, .
[lola][.]
[lola][.] Time elapsed: 360 secs. Pages in use: 178
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 20/813 11/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 1954817 m, 98623 m/sec, 6278265 t fired, .
[lola][.]
[lola][.] Time elapsed: 365 secs. Pages in use: 181
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 25/813 13/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 2445651 m, 98166 m/sec, 7886325 t fired, .
[lola][.]
[lola][.] Time elapsed: 370 secs. Pages in use: 183
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 30/813 16/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 2935465 m, 97962 m/sec, 9494919 t fired, .
[lola][.]
[lola][.] Time elapsed: 375 secs. Pages in use: 186
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 35/813 18/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 3425790 m, 98065 m/sec, 11104336 t fired, .
[lola][.]
[lola][.] Time elapsed: 380 secs. Pages in use: 188
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 40/813 21/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 3913497 m, 97541 m/sec, 12706535 t fired, .
[lola][.]
[lola][.] Time elapsed: 385 secs. Pages in use: 191
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 45/813 23/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 4400410 m, 97382 m/sec, 14307482 t fired, .
[lola][.]
[lola][.] Time elapsed: 390 secs. Pages in use: 193
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 50/813 25/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 4879198 m, 95757 m/sec, 15884758 t fired, .
[lola][.]
[lola][.] Time elapsed: 395 secs. Pages in use: 195
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 55/813 28/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 5362706 m, 96701 m/sec, 17474721 t fired, .
[lola][.]
[lola][.] Time elapsed: 400 secs. Pages in use: 198
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 60/813 30/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 5841715 m, 95801 m/sec, 19051841 t fired, .
[lola][.]
[lola][.] Time elapsed: 405 secs. Pages in use: 200
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 65/813 33/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 6323813 m, 96419 m/sec, 20639966 t fired, .
[lola][.]
[lola][.] Time elapsed: 410 secs. Pages in use: 203
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 70/813 35/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 6807388 m, 96715 m/sec, 22232601 t fired, .
[lola][.]
[lola][.] Time elapsed: 415 secs. Pages in use: 205
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 75/813 38/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 7282314 m, 94985 m/sec, 23800059 t fired, .
[lola][.]
[lola][.] Time elapsed: 420 secs. Pages in use: 208
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 80/813 40/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 7761851 m, 95907 m/sec, 25378413 t fired, .
[lola][.]
[lola][.] Time elapsed: 425 secs. Pages in use: 210
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 85/813 43/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 8234497 m, 94529 m/sec, 26938802 t fired, .
[lola][.]
[lola][.] Time elapsed: 430 secs. Pages in use: 213
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 90/813 45/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 8709425 m, 94985 m/sec, 28503672 t fired, .
[lola][.]
[lola][.] Time elapsed: 435 secs. Pages in use: 215
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 95/813 47/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 9183628 m, 94840 m/sec, 30068690 t fired, .
[lola][.]
[lola][.] Time elapsed: 440 secs. Pages in use: 217
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 100/813 50/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 9654265 m, 94127 m/sec, 31624343 t fired, .
[lola][.]
[lola][.] Time elapsed: 445 secs. Pages in use: 220
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 105/813 52/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 10130425 m, 95232 m/sec, 33191293 t fired, .
[lola][.]
[lola][.] Time elapsed: 450 secs. Pages in use: 222
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 110/813 55/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 10600717 m, 94058 m/sec, 34746306 t fired, .
[lola][.]
[lola][.] Time elapsed: 455 secs. Pages in use: 225
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 115/813 57/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 11075624 m, 94981 m/sec, 36309585 t fired, .
[lola][.]
[lola][.] Time elapsed: 460 secs. Pages in use: 227
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 120/813 59/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 11544295 m, 93734 m/sec, 37858132 t fired, .
[lola][.]
[lola][.] Time elapsed: 465 secs. Pages in use: 229
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 125/813 62/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 12013392 m, 93819 m/sec, 39410465 t fired, .
[lola][.]
[lola][.] Time elapsed: 470 secs. Pages in use: 232
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 130/813 64/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 12486032 m, 94528 m/sec, 40966535 t fired, .
[lola][.]
[lola][.] Time elapsed: 475 secs. Pages in use: 234
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 135/813 67/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 12954144 m, 93622 m/sec, 42514834 t fired, .
[lola][.]
[lola][.] Time elapsed: 480 secs. Pages in use: 237
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 140/813 69/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 13421828 m, 93536 m/sec, 44061960 t fired, .
[lola][.]
[lola][.] Time elapsed: 485 secs. Pages in use: 239
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 145/813 71/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 13891976 m, 94029 m/sec, 45611115 t fired, .
[lola][.]
[lola][.] Time elapsed: 490 secs. Pages in use: 241
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 150/813 74/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 14357522 m, 93109 m/sec, 47152176 t fired, .
[lola][.]
[lola][.] Time elapsed: 495 secs. Pages in use: 244
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 155/813 76/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 14824967 m, 93489 m/sec, 48701487 t fired, .
[lola][.]
[lola][.] Time elapsed: 500 secs. Pages in use: 246
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 160/813 78/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 15296640 m, 94334 m/sec, 50252354 t fired, .
[lola][.]
[lola][.] Time elapsed: 505 secs. Pages in use: 248
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 165/813 81/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 15764348 m, 93541 m/sec, 51801072 t fired, .
[lola][.]
[lola][.] Time elapsed: 510 secs. Pages in use: 251
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 170/813 83/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 16232903 m, 93711 m/sec, 53353371 t fired, .
[lola][.]
[lola][.] Time elapsed: 515 secs. Pages in use: 253
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 175/813 86/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 16705913 m, 94602 m/sec, 54911404 t fired, .
[lola][.]
[lola][.] Time elapsed: 520 secs. Pages in use: 256
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 180/813 88/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 17172707 m, 93358 m/sec, 56456443 t fired, .
[lola][.]
[lola][.] Time elapsed: 525 secs. Pages in use: 258
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 185/813 90/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 17640015 m, 93461 m/sec, 58006263 t fired, .
[lola][.]
[lola][.] Time elapsed: 530 secs. Pages in use: 260
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 190/813 93/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 18109308 m, 93858 m/sec, 59552930 t fired, .
[lola][.]
[lola][.] Time elapsed: 535 secs. Pages in use: 263
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 195/813 95/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 18575046 m, 93147 m/sec, 61094239 t fired, .
[lola][.]
[lola][.] Time elapsed: 540 secs. Pages in use: 265
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 200/813 97/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 19040710 m, 93132 m/sec, 62637937 t fired, .
[lola][.]
[lola][.] Time elapsed: 545 secs. Pages in use: 267
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 205/813 100/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 19504758 m, 92809 m/sec, 64177262 t fired, .
[lola][.]
[lola][.] Time elapsed: 550 secs. Pages in use: 270
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 210/813 102/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 19976708 m, 94390 m/sec, 65729912 t fired, .
[lola][.]
[lola][.] Time elapsed: 555 secs. Pages in use: 272
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 215/813 104/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 20440651 m, 92788 m/sec, 67267103 t fired, .
[lola][.]
[lola][.] Time elapsed: 560 secs. Pages in use: 274
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 220/813 107/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 20904605 m, 92790 m/sec, 68806144 t fired, .
[lola][.]
[lola][.] Time elapsed: 565 secs. Pages in use: 277
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 225/813 109/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 21370363 m, 93151 m/sec, 70344637 t fired, .
[lola][.]
[lola][.] Time elapsed: 570 secs. Pages in use: 279
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 230/813 111/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 21836702 m, 93267 m/sec, 71885020 t fired, .
[lola][.]
[lola][.] Time elapsed: 575 secs. Pages in use: 281
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 235/813 114/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 22299034 m, 92466 m/sec, 73417580 t fired, .
[lola][.]
[lola][.] Time elapsed: 580 secs. Pages in use: 284
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 240/813 116/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 22762145 m, 92622 m/sec, 74955465 t fired, .
[lola][.]
[lola][.] Time elapsed: 585 secs. Pages in use: 286
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 245/813 118/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 23226912 m, 92953 m/sec, 76489210 t fired, .
[lola][.]
[lola][.] Time elapsed: 590 secs. Pages in use: 288
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 250/813 121/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 23692982 m, 93214 m/sec, 78029789 t fired, .
[lola][.]
[lola][.] Time elapsed: 595 secs. Pages in use: 291
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 255/813 123/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 24155563 m, 92516 m/sec, 79563077 t fired, .
[lola][.]
[lola][.] Time elapsed: 600 secs. Pages in use: 293
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 260/813 125/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 24610734 m, 91034 m/sec, 81073955 t fired, .
[lola][.]
[lola][.] Time elapsed: 605 secs. Pages in use: 295
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 265/813 128/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 25020692 m, 81991 m/sec, 82432370 t fired, .
[lola][.]
[lola][.] Time elapsed: 610 secs. Pages in use: 298
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 270/813 130/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 25433697 m, 82601 m/sec, 83793464 t fired, .
[lola][.]
[lola][.] Time elapsed: 615 secs. Pages in use: 300
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 275/813 132/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 25848752 m, 83011 m/sec, 85168574 t fired, .
[lola][.]
[lola][.] Time elapsed: 620 secs. Pages in use: 302
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 280/813 134/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 26225192 m, 75288 m/sec, 86417662 t fired, .
[lola][.]
[lola][.] Time elapsed: 625 secs. Pages in use: 304
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 285/813 135/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 26600204 m, 75002 m/sec, 87662698 t fired, .
[lola][.]
[lola][.] Time elapsed: 630 secs. Pages in use: 305
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 290/813 137/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 26985145 m, 76988 m/sec, 88941526 t fired, .
[lola][.]
[lola][.] Time elapsed: 635 secs. Pages in use: 307
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 295/813 139/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 27367109 m, 76392 m/sec, 90195824 t fired, .
[lola][.]
[lola][.] Time elapsed: 640 secs. Pages in use: 309
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 300/813 141/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 27787684 m, 84115 m/sec, 91590332 t fired, .
[lola][.]
[lola][.] Time elapsed: 645 secs. Pages in use: 311
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 305/813 144/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 28201961 m, 82855 m/sec, 92954920 t fired, .
[lola][.]
[lola][.] Time elapsed: 650 secs. Pages in use: 314
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 310/813 145/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 28580013 m, 75610 m/sec, 94204997 t fired, .
[lola][.]
[lola][.] Time elapsed: 655 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 315/813 147/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 28959002 m, 75797 m/sec, 95462122 t fired, .
[lola][.]
[lola][.] Time elapsed: 660 secs. Pages in use: 317
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 320/813 149/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 29334654 m, 75130 m/sec, 96709134 t fired, .
[lola][.]
[lola][.] Time elapsed: 665 secs. Pages in use: 319
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 325/813 151/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 29738250 m, 80719 m/sec, 98050384 t fired, .
[lola][.]
[lola][.] Time elapsed: 670 secs. Pages in use: 321
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 330/813 153/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 30170027 m, 86355 m/sec, 99485211 t fired, .
[lola][.]
[lola][.] Time elapsed: 675 secs. Pages in use: 323
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 335/813 156/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 30593403 m, 84675 m/sec, 100879007 t fired, .
[lola][.]
[lola][.] Time elapsed: 680 secs. Pages in use: 326
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 340/813 158/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 31018770 m, 85073 m/sec, 102287272 t fired, .
[lola][.]
[lola][.] Time elapsed: 685 secs. Pages in use: 328
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 345/813 160/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 31443477 m, 84941 m/sec, 103696519 t fired, .
[lola][.]
[lola][.] Time elapsed: 690 secs. Pages in use: 330
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 350/813 162/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 31870324 m, 85369 m/sec, 105115851 t fired, .
[lola][.]
[lola][.] Time elapsed: 695 secs. Pages in use: 332
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 355/813 164/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 32301349 m, 86205 m/sec, 106548183 t fired, .
[lola][.]
[lola][.] Time elapsed: 700 secs. Pages in use: 334
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 360/813 166/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 32728453 m, 85420 m/sec, 107958360 t fired, .
[lola][.]
[lola][.] Time elapsed: 705 secs. Pages in use: 336
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 365/813 168/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 33130567 m, 80422 m/sec, 109287491 t fired, .
[lola][.]
[lola][.] Time elapsed: 710 secs. Pages in use: 338
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 370/813 170/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 33532307 m, 80348 m/sec, 110619418 t fired, .
[lola][.]
[lola][.] Time elapsed: 715 secs. Pages in use: 340
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 375/813 173/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 33953867 m, 84312 m/sec, 112019145 t fired, .
[lola][.]
[lola][.] Time elapsed: 720 secs. Pages in use: 343
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 380/813 175/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 34377047 m, 84636 m/sec, 113425689 t fired, .
[lola][.]
[lola][.] Time elapsed: 725 secs. Pages in use: 345
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 385/813 177/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 34792962 m, 83183 m/sec, 114808832 t fired, .
[lola][.]
[lola][.] Time elapsed: 730 secs. Pages in use: 347
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 390/813 179/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 35236941 m, 88795 m/sec, 116273908 t fired, .
[lola][.]
[lola][.] Time elapsed: 735 secs. Pages in use: 349
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 395/813 181/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 35679010 m, 88413 m/sec, 117736112 t fired, .
[lola][.]
[lola][.] Time elapsed: 740 secs. Pages in use: 351
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 400/813 183/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 36117098 m, 87617 m/sec, 119189225 t fired, .
[lola][.]
[lola][.] Time elapsed: 745 secs. Pages in use: 353
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 405/813 186/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 36559058 m, 88392 m/sec, 120657456 t fired, .
[lola][.]
[lola][.] Time elapsed: 750 secs. Pages in use: 356
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 410/813 188/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 37004376 m, 89063 m/sec, 122137998 t fired, .
[lola][.]
[lola][.] Time elapsed: 755 secs. Pages in use: 358
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 415/813 190/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 37456117 m, 90348 m/sec, 123640234 t fired, .
[lola][.]
[lola][.] Time elapsed: 760 secs. Pages in use: 360
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 420/813 192/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 37897212 m, 88219 m/sec, 125093159 t fired, .
[lola][.]
[lola][.] Time elapsed: 765 secs. Pages in use: 362
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 425/813 194/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 38299320 m, 80421 m/sec, 126424320 t fired, .
[lola][.]
[lola][.] Time elapsed: 770 secs. Pages in use: 364
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 430/813 197/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 38719476 m, 84031 m/sec, 127818986 t fired, .
[lola][.]
[lola][.] Time elapsed: 775 secs. Pages in use: 367
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 435/813 199/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 39139286 m, 83962 m/sec, 129213307 t fired, .
[lola][.]
[lola][.] Time elapsed: 780 secs. Pages in use: 369
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 440/813 201/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 39561870 m, 84516 m/sec, 130618958 t fired, .
[lola][.]
[lola][.] Time elapsed: 785 secs. Pages in use: 371
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 445/813 203/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 39986611 m, 84948 m/sec, 132031394 t fired, .
[lola][.]
[lola][.] Time elapsed: 790 secs. Pages in use: 373
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 450/813 205/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 40406417 m, 83961 m/sec, 133415241 t fired, .
[lola][.]
[lola][.] Time elapsed: 795 secs. Pages in use: 375
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 455/813 207/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 40829878 m, 84692 m/sec, 134816810 t fired, .
[lola][.]
[lola][.] Time elapsed: 800 secs. Pages in use: 377
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 460/813 209/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 41249652 m, 83954 m/sec, 136209266 t fired, .
[lola][.]
[lola][.] Time elapsed: 805 secs. Pages in use: 379
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 465/813 211/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 41669117 m, 83893 m/sec, 137602692 t fired, .
[lola][.]
[lola][.] Time elapsed: 810 secs. Pages in use: 381
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 470/813 214/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 42091257 m, 84428 m/sec, 139005689 t fired, .
[lola][.]
[lola][.] Time elapsed: 815 secs. Pages in use: 384
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 475/813 216/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 42514929 m, 84734 m/sec, 140415894 t fired, .
[lola][.]
[lola][.] Time elapsed: 820 secs. Pages in use: 386
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 480/813 218/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 42938223 m, 84658 m/sec, 141816768 t fired, .
[lola][.]
[lola][.] Time elapsed: 825 secs. Pages in use: 388
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 485/813 220/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 43356032 m, 83561 m/sec, 143195958 t fired, .
[lola][.]
[lola][.] Time elapsed: 830 secs. Pages in use: 390
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 490/813 222/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 43780661 m, 84925 m/sec, 144603529 t fired, .
[lola][.]
[lola][.] Time elapsed: 835 secs. Pages in use: 392
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 495/813 224/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 44199507 m, 83769 m/sec, 145993931 t fired, .
[lola][.]
[lola][.] Time elapsed: 840 secs. Pages in use: 394
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 500/813 226/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 44610146 m, 82127 m/sec, 147359272 t fired, .
[lola][.]
[lola][.] Time elapsed: 845 secs. Pages in use: 396
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 505/813 228/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 45026145 m, 83199 m/sec, 148742579 t fired, .
[lola][.]
[lola][.] Time elapsed: 850 secs. Pages in use: 398
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 510/813 230/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 45422112 m, 79193 m/sec, 150059940 t fired, .
[lola][.]
[lola][.] Time elapsed: 855 secs. Pages in use: 400
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 515/813 232/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 45829955 m, 81568 m/sec, 151406960 t fired, .
[lola][.]
[lola][.] Time elapsed: 860 secs. Pages in use: 402
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 520/813 234/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 46232777 m, 80564 m/sec, 152738153 t fired, .
[lola][.]
[lola][.] Time elapsed: 865 secs. Pages in use: 404
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 525/813 236/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 46662046 m, 85853 m/sec, 154161552 t fired, .
[lola][.]
[lola][.] Time elapsed: 870 secs. Pages in use: 406
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 530/813 239/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 47111629 m, 89916 m/sec, 155654376 t fired, .
[lola][.]
[lola][.] Time elapsed: 875 secs. Pages in use: 409
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 535/813 241/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 47562093 m, 90092 m/sec, 157152132 t fired, .
[lola][.]
[lola][.] Time elapsed: 880 secs. Pages in use: 411
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 540/813 243/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 48006758 m, 88933 m/sec, 158631394 t fired, .
[lola][.]
[lola][.] Time elapsed: 885 secs. Pages in use: 413
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 545/813 245/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 48421443 m, 82937 m/sec, 160009756 t fired, .
[lola][.]
[lola][.] Time elapsed: 890 secs. Pages in use: 415
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 550/813 247/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 48791415 m, 73994 m/sec, 161230341 t fired, .
[lola][.]
[lola][.] Time elapsed: 895 secs. Pages in use: 417
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 555/813 249/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 49208594 m, 83435 m/sec, 162610261 t fired, .
[lola][.]
[lola][.] Time elapsed: 900 secs. Pages in use: 419
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 560/813 251/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 49617406 m, 81762 m/sec, 163966339 t fired, .
[lola][.]
[lola][.] Time elapsed: 905 secs. Pages in use: 421
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 565/813 254/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 50048946 m, 86308 m/sec, 165399337 t fired, .
[lola][.]
[lola][.] Time elapsed: 910 secs. Pages in use: 424
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 570/813 256/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 50468229 m, 83856 m/sec, 166793992 t fired, .
[lola][.]
[lola][.] Time elapsed: 915 secs. Pages in use: 426
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 575/813 258/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 50879129 m, 82180 m/sec, 168161538 t fired, .
[lola][.]
[lola][.] Time elapsed: 920 secs. Pages in use: 428
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 580/813 260/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 51284768 m, 81127 m/sec, 169510915 t fired, .
[lola][.]
[lola][.] Time elapsed: 925 secs. Pages in use: 430
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 585/813 262/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 51701242 m, 83294 m/sec, 170886887 t fired, .
[lola][.]
[lola][.] Time elapsed: 930 secs. Pages in use: 432
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 590/813 264/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 52108925 m, 81536 m/sec, 172234105 t fired, .
[lola][.]
[lola][.] Time elapsed: 935 secs. Pages in use: 434
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 595/813 266/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 52532138 m, 84642 m/sec, 173637070 t fired, .
[lola][.]
[lola][.] Time elapsed: 940 secs. Pages in use: 436
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 600/813 268/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 52980076 m, 89587 m/sec, 175124554 t fired, .
[lola][.]
[lola][.] Time elapsed: 945 secs. Pages in use: 438
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 605/813 270/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 53429598 m, 89904 m/sec, 176619104 t fired, .
[lola][.]
[lola][.] Time elapsed: 950 secs. Pages in use: 440
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 610/813 273/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 53877933 m, 89667 m/sec, 178110722 t fired, .
[lola][.]
[lola][.] Time elapsed: 955 secs. Pages in use: 443
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 615/813 275/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 54331107 m, 90634 m/sec, 179619172 t fired, .
[lola][.]
[lola][.] Time elapsed: 960 secs. Pages in use: 445
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 620/813 277/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 54783253 m, 90429 m/sec, 181113866 t fired, .
[lola][.]
[lola][.] Time elapsed: 965 secs. Pages in use: 447
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 625/813 280/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 55229192 m, 89187 m/sec, 182587043 t fired, .
[lola][.]
[lola][.] Time elapsed: 970 secs. Pages in use: 450
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 630/813 282/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 55676704 m, 89502 m/sec, 184072421 t fired, .
[lola][.]
[lola][.] Time elapsed: 975 secs. Pages in use: 452
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 635/813 284/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 56120754 m, 88810 m/sec, 185547997 t fired, .
[lola][.]
[lola][.] Time elapsed: 980 secs. Pages in use: 454
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 640/813 286/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 56565559 m, 88961 m/sec, 187025780 t fired, .
[lola][.]
[lola][.] Time elapsed: 985 secs. Pages in use: 456
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 645/813 288/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 57014326 m, 89753 m/sec, 188518940 t fired, .
[lola][.]
[lola][.] Time elapsed: 990 secs. Pages in use: 458
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 650/813 291/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 57463856 m, 89906 m/sec, 190015205 t fired, .
[lola][.]
[lola][.] Time elapsed: 995 secs. Pages in use: 461
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 655/813 293/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 57914758 m, 90180 m/sec, 191506726 t fired, .
[lola][.]
[lola][.] Time elapsed: 1000 secs. Pages in use: 463
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 660/813 295/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 58358884 m, 88825 m/sec, 192974149 t fired, .
[lola][.]
[lola][.] Time elapsed: 1005 secs. Pages in use: 465
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 665/813 297/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 58803759 m, 88975 m/sec, 194448881 t fired, .
[lola][.]
[lola][.] Time elapsed: 1010 secs. Pages in use: 467
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 670/813 300/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 59247487 m, 88745 m/sec, 195923330 t fired, .
[lola][.]
[lola][.] Time elapsed: 1015 secs. Pages in use: 470
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 675/813 302/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 59692237 m, 88950 m/sec, 197402172 t fired, .
[lola][.]
[lola][.] Time elapsed: 1020 secs. Pages in use: 472
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 680/813 304/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 60142166 m, 89985 m/sec, 198899182 t fired, .
[lola][.]
[lola][.] Time elapsed: 1025 secs. Pages in use: 474
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 685/813 306/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 60592351 m, 90037 m/sec, 200397708 t fired, .
[lola][.]
[lola][.] Time elapsed: 1030 secs. Pages in use: 476
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 690/813 309/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 61046215 m, 90772 m/sec, 201908568 t fired, .
[lola][.]
[lola][.] Time elapsed: 1035 secs. Pages in use: 479
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 695/813 311/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 61488387 m, 88434 m/sec, 203362149 t fired, .
[lola][.]
[lola][.] Time elapsed: 1040 secs. Pages in use: 481
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 700/813 313/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 61935978 m, 89518 m/sec, 204845938 t fired, .
[lola][.]
[lola][.] Time elapsed: 1045 secs. Pages in use: 483
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 705/813 315/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 62382444 m, 89293 m/sec, 206327102 t fired, .
[lola][.]
[lola][.] Time elapsed: 1050 secs. Pages in use: 485
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 710/813 318/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 62827931 m, 89097 m/sec, 207807935 t fired, .
[lola][.]
[lola][.] Time elapsed: 1055 secs. Pages in use: 488
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 715/813 320/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 63272683 m, 88950 m/sec, 209288459 t fired, .
[lola][.]
[lola][.] Time elapsed: 1060 secs. Pages in use: 490
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 720/813 322/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 63721501 m, 89763 m/sec, 210781612 t fired, .
[lola][.]
[lola][.] Time elapsed: 1065 secs. Pages in use: 492
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 725/813 324/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 64173293 m, 90358 m/sec, 212286236 t fired, .
[lola][.]
[lola][.] Time elapsed: 1070 secs. Pages in use: 494
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 730/813 327/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 64620219 m, 89385 m/sec, 213760551 t fired, .
[lola][.]
[lola][.] Time elapsed: 1075 secs. Pages in use: 497
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 735/813 329/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 65066336 m, 89223 m/sec, 215236772 t fired, .
[lola][.]
[lola][.] Time elapsed: 1080 secs. Pages in use: 499
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 740/813 331/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 65512877 m, 89308 m/sec, 216717925 t fired, .
[lola][.]
[lola][.] Time elapsed: 1085 secs. Pages in use: 501
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 745/813 333/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 65957944 m, 89013 m/sec, 218197150 t fired, .
[lola][.]
[lola][.] Time elapsed: 1090 secs. Pages in use: 503
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 750/813 336/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 66402189 m, 88849 m/sec, 219673835 t fired, .
[lola][.]
[lola][.] Time elapsed: 1095 secs. Pages in use: 506
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 755/813 338/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 66851673 m, 89896 m/sec, 221169792 t fired, .
[lola][.]
[lola][.] Time elapsed: 1100 secs. Pages in use: 508
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 760/813 340/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 67297959 m, 89257 m/sec, 222655252 t fired, .
[lola][.]
[lola][.] Time elapsed: 1105 secs. Pages in use: 510
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 765/813 342/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 67752124 m, 90833 m/sec, 224168118 t fired, .
[lola][.]
[lola][.] Time elapsed: 1110 secs. Pages in use: 512
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 770/813 345/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 68191276 m, 87830 m/sec, 225612946 t fired, .
[lola][.]
[lola][.] Time elapsed: 1115 secs. Pages in use: 515
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 775/813 347/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 68638014 m, 89347 m/sec, 227092616 t fired, .
[lola][.]
[lola][.] Time elapsed: 1120 secs. Pages in use: 517
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 780/813 349/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 69081063 m, 88609 m/sec, 228562984 t fired, .
[lola][.]
[lola][.] Time elapsed: 1125 secs. Pages in use: 519
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 785/813 351/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 69522573 m, 88302 m/sec, 230030347 t fired, .
[lola][.]
[lola][.] Time elapsed: 1130 secs. Pages in use: 521
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 790/813 353/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 69967070 m, 88899 m/sec, 231508171 t fired, .
[lola][.]
[lola][.] Time elapsed: 1135 secs. Pages in use: 523
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 795/813 356/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 70412413 m, 89068 m/sec, 232990489 t fired, .
[lola][.]
[lola][.] Time elapsed: 1140 secs. Pages in use: 526
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 800/813 358/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 70857634 m, 89044 m/sec, 234473663 t fired, .
[lola][.]
[lola][.] Time elapsed: 1145 secs. Pages in use: 528
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 805/813 360/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 71284831 m, 85439 m/sec, 235896658 t fired, .
[lola][.]
[lola][.] Time elapsed: 1150 secs. Pages in use: 530
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 810/813 362/2000 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 71726091 m, 88252 m/sec, 237347952 t fired, .
[lola][.]
[lola][.] Time elapsed: 1155 secs. Pages in use: 532
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][W] CANCELED task # 10 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 (local timeout)
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 1 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1160 secs. Pages in use: 535
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] LAUNCH task # 7 (type EXCL) for 6 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02
[lola][I] time limit : 813 sec
[lola][I] memory limit: 2000 pages
[lola][I] LAUNCH task # 10 (type EXCL) for 9 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03
[lola][I] time limit : 2440 sec
[lola][I] memory limit: 5 pages
[lola][I] FINISHED task # 7 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02
[lola][I] result : false
[lola][I] markings : 413
[lola][I] fired transitions : 946
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 5/813 3/5 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 430477 m, -14259122 m/sec, 1316797 t fired, .
[lola][.]
[lola][.] Time elapsed: 1165 secs. Pages in use: 541
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 10 CTL EXCL 10/813 5/5 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 853980 m, 84700 m/sec, 2685378 t fired, .
[lola][.]
[lola][.] Time elapsed: 1170 secs. Pages in use: 545
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] CANCELED task # 10 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03 (memory limit exceeded)
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ 0 2 0 0 6 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1175 secs. Pages in use: 545
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] LAUNCH task # 61 (type EXCL) for 18 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06
[lola][I] time limit : 1212 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 61 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06
[lola][I] result : false
[lola][I] markings : 1
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I] LAUNCH task # 57 (type EXCL) for 18 BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06
[lola][I] time limit : 2425 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 57 (type EXCL) for BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06
[lola][I] result : true
[lola][I] markings : 363
[lola][I] fired transitions : 362
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1180 secs. Pages in use: 545
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1185 secs. Pages in use: 546
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1190 secs. Pages in use: 549
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1195 secs. Pages in use: 551
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1200 secs. Pages in use: 553
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1205 secs. Pages in use: 555
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1210 secs. Pages in use: 558
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1215 secs. Pages in use: 560
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1220 secs. Pages in use: 562
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1225 secs. Pages in use: 564
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1230 secs. Pages in use: 566
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1235 secs. Pages in use: 569
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1240 secs. Pages in use: 571
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1245 secs. Pages in use: 573
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1250 secs. Pages in use: 575
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1255 secs. Pages in use: 577
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1260 secs. Pages in use: 580
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1265 secs. Pages in use: 582
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1270 secs. Pages in use: 584
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1275 secs. Pages in use: 586
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1280 secs. Pages in use: 588
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1285 secs. Pages in use: 590
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1290 secs. Pages in use: 593
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1295 secs. Pages in use: 595
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1300 secs. Pages in use: 597
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1305 secs. Pages in use: 599
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1310 secs. Pages in use: 601
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1315 secs. Pages in use: 603
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1320 secs. Pages in use: 606
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1325 secs. Pages in use: 608
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1330 secs. Pages in use: 610
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1335 secs. Pages in use: 612
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1340 secs. Pages in use: 615
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1345 secs. Pages in use: 617
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1350 secs. Pages in use: 619
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1355 secs. Pages in use: 621
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1360 secs. Pages in use: 624
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1365 secs. Pages in use: 626
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1370 secs. Pages in use: 628
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1375 secs. Pages in use: 630
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1380 secs. Pages in use: 632
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1385 secs. Pages in use: 635
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1390 secs. Pages in use: 637
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1395 secs. Pages in use: 639
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1400 secs. Pages in use: 642
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1405 secs. Pages in use: 644
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1410 secs. Pages in use: 646
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1415 secs. Pages in use: 648
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1420 secs. Pages in use: 650
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1425 secs. Pages in use: 652
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1430 secs. Pages in use: 654
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1435 secs. Pages in use: 657
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1440 secs. Pages in use: 659
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1445 secs. Pages in use: 661
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1450 secs. Pages in use: 663
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1455 secs. Pages in use: 666
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1460 secs. Pages in use: 668
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1465 secs. Pages in use: 670
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1470 secs. Pages in use: 672
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1475 secs. Pages in use: 674
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1480 secs. Pages in use: 676
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1485 secs. Pages in use: 678
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1490 secs. Pages in use: 680
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1495 secs. Pages in use: 682
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1500 secs. Pages in use: 684
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1505 secs. Pages in use: 686
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1510 secs. Pages in use: 688
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1515 secs. Pages in use: 690
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1520 secs. Pages in use: 693
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1525 secs. Pages in use: 695
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1530 secs. Pages in use: 697
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1535 secs. Pages in use: 699
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1540 secs. Pages in use: 701
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1545 secs. Pages in use: 703
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1550 secs. Pages in use: 705
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1555 secs. Pages in use: 707
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1560 secs. Pages in use: 709
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1565 secs. Pages in use: 711
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1570 secs. Pages in use: 713
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1575 secs. Pages in use: 715
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1580 secs. Pages in use: 718
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1585 secs. Pages in use: 720
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1590 secs. Pages in use: 722
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1595 secs. Pages in use: 724
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1600 secs. Pages in use: 726
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1605 secs. Pages in use: 729
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1610 secs. Pages in use: 731
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1615 secs. Pages in use: 733
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1620 secs. Pages in use: 735
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1625 secs. Pages in use: 738
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1630 secs. Pages in use: 740
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1635 secs. Pages in use: 742
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1640 secs. Pages in use: 744
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1645 secs. Pages in use: 747
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1650 secs. Pages in use: 749
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1655 secs. Pages in use: 751
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1660 secs. Pages in use: 753
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1665 secs. Pages in use: 756
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1670 secs. Pages in use: 758
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1675 secs. Pages in use: 760
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1680 secs. Pages in use: 762
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1685 secs. Pages in use: 764
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1690 secs. Pages in use: 767
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1695 secs. Pages in use: 769
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1700 secs. Pages in use: 771
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1705 secs. Pages in use: 773
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1710 secs. Pages in use: 776
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1715 secs. Pages in use: 778
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1720 secs. Pages in use: 780
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1725 secs. Pages in use: 782
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1730 secs. Pages in use: 784
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1735 secs. Pages in use: 786
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1740 secs. Pages in use: 788
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1745 secs. Pages in use: 790
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1750 secs. Pages in use: 792
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1755 secs. Pages in use: 795
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1760 secs. Pages in use: 797
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1765 secs. Pages in use: 799
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1770 secs. Pages in use: 801
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1775 secs. Pages in use: 803
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1780 secs. Pages in use: 806
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1785 secs. Pages in use: 808
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1790 secs. Pages in use: 810
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1795 secs. Pages in use: 812
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1800 secs. Pages in use: 814
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1805 secs. Pages in use: 817
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1810 secs. Pages in use: 819
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1815 secs. Pages in use: 821
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1820 secs. Pages in use: 823
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1825 secs. Pages in use: 825
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1830 secs. Pages in use: 827
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1835 secs. Pages in use: 829
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1840 secs. Pages in use: 831
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1845 secs. Pages in use: 834
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1850 secs. Pages in use: 836
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1855 secs. Pages in use: 838
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1860 secs. Pages in use: 840
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1865 secs. Pages in use: 842
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1870 secs. Pages in use: 845
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1875 secs. Pages in use: 846
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1880 secs. Pages in use: 848
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-14: INITIAL false preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-15: INITIAL true preprocessing
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-03: CTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-04: CTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1885 secs. Pages in use: 850
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-00: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-01: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-02: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-05: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-06: DISJ false DISJ
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-07: CTL true CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-08: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-09: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-10: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-11: INITIAL true preprocessing
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-12: CTL false CTL model checker
[lola][.] BridgeAndVehicles-PT-V50P50N20-CTLCardinality-2024-13: CTL false CTL model checker

========== file over 1MB has been truncated ======
retrieve it from the run archives if needed

Sequence of Actions to be Executed by the VM

This is useful if one wants to reexecute the tool in the VM from the submitted image disk.

set -x
# this is for BenchKit: configuration of major elements for the test
export BK_INPUT="BridgeAndVehicles-PT-V50P50N20"
export BK_EXAMINATION="CTLCardinality"
export BK_TOOL="lola"
export BK_RESULT_DIR="/tmp/BK_RESULTS/OUTPUTS"
export BK_TIME_CONFINEMENT="3600"
export BK_MEMORY_CONFINEMENT="16384"
export BK_BIN_PATH="/home/mcc/BenchKit/bin/"

# this is specific to your benchmark or test

export BIN_DIR="$HOME/BenchKit/bin"

# remove the execution directoty if it exists (to avoid increse of .vmdk images)
if [ -d execution ] ; then
rm -rf execution
fi

# this is for BenchKit: explicit launching of the test
echo "====================================================================="
echo " Generated by BenchKit 2-5568"
echo " Executing tool lola"
echo " Input is BridgeAndVehicles-PT-V50P50N20, examination is CTLCardinality"
echo " Time confinement is $BK_TIME_CONFINEMENT seconds"
echo " Memory confinement is 16384 MBytes"
echo " Number of cores is 4"
echo " Run identifier is r049-tajo-171620400400257"
echo "====================================================================="
echo
echo "--------------------"
echo "preparation of the directory to be used:"

tar xzf /home/mcc/BenchKit/INPUTS/BridgeAndVehicles-PT-V50P50N20.tgz
mv BridgeAndVehicles-PT-V50P50N20 execution
cd execution
if [ "CTLCardinality" = "ReachabilityDeadlock" ] || [ "CTLCardinality" = "UpperBounds" ] || [ "CTLCardinality" = "QuasiLiveness" ] || [ "CTLCardinality" = "StableMarking" ] || [ "CTLCardinality" = "Liveness" ] || [ "CTLCardinality" = "OneSafe" ] || [ "CTLCardinality" = "StateSpace" ]; then
rm -f GenericPropertiesVerdict.xml
fi
pwd
ls -lh

echo
echo "--------------------"
echo "content from stdout:"
echo
echo "=== Data for post analysis generated by BenchKit (invocation template)"
echo
if [ "CTLCardinality" = "UpperBounds" ] ; then
echo "The expected result is a vector of positive values"
echo NUM_VECTOR
elif [ "CTLCardinality" != "StateSpace" ] ; then
echo "The expected result is a vector of booleans"
echo BOOL_VECTOR
else
echo "no data necessary for post analysis"
fi
echo
if [ -f "CTLCardinality.txt" ] ; then
echo "here is the order used to build the result vector(from text file)"
for x in $(grep Property CTLCardinality.txt | cut -d ' ' -f 2 | sort -u) ; do
echo "FORMULA_NAME $x"
done
elif [ -f "CTLCardinality.xml" ] ; then # for cunf (txt files deleted;-)
echo echo "here is the order used to build the result vector(from xml file)"
for x in $(grep '' CTLCardinality.xml | cut -d '>' -f 2 | cut -d '<' -f 1 | sort -u) ; do
echo "FORMULA_NAME $x"
done
elif [ "CTLCardinality" = "ReachabilityDeadlock" ] || [ "CTLCardinality" = "QuasiLiveness" ] || [ "CTLCardinality" = "StableMarking" ] || [ "CTLCardinality" = "Liveness" ] || [ "CTLCardinality" = "OneSafe" ] ; then
echo "FORMULA_NAME CTLCardinality"
fi
echo
echo "=== Now, execution of the tool begins"
echo
echo -n "BK_START "
date -u +%s%3N
echo
timeout -s 9 $BK_TIME_CONFINEMENT bash -c "/home/mcc/BenchKit/BenchKit_head.sh 2> STDERR ; echo ; echo -n \"BK_STOP \" ; date -u +%s%3N"
if [ $? -eq 137 ] ; then
echo
echo "BK_TIME_CONFINEMENT_REACHED"
fi
echo
echo "--------------------"
echo "content from stderr:"
echo
cat STDERR ;