fond
Model Checking Contest 2024
14th edition, Geneva, Switzerland, June 25, 2024
Execution of r049-tajo-171620400200156
Last Updated
July 7, 2024

About the Execution of LoLA for BridgeAndVehicles-COL-V80P50N50

Execution Summary
Max Memory
Used (MB)
Time wait (ms) CPU Usage (ms) I/O Wait (ms) Computed Result Execution
Status
14486.712 2451667.00 2638499.00 472.90 TFF?FFTFFT?T??TF normal

Execution Chart

We display below the execution chart for this examination (boot time has been removed).

Trace from the execution

Formatting '/mnt/tpsp/fkordon/mcc2024-input.r049-tajo-171620400200156.qcow2', fmt=qcow2 size=4294967296 backing_file='/mnt/tpsp/fkordon/mcc2024-input.qcow2' backing_fmt='qcow2' encryption=off cluster_size=65536 lazy_refcounts=off
Waiting for the VM to be ready (probing ssh)
............................
=====================================================================
Generated by BenchKit 2-5568
Executing tool lola
Input is BridgeAndVehicles-COL-V80P50N50, examination is LTLFireability
Time confinement is 3600 seconds
Memory confinement is 16384 MBytes
Number of cores is 4
Run identifier is r049-tajo-171620400200156
=====================================================================

--------------------
preparation of the directory to be used:
/home/mcc/execution
total 616K
-rw-r--r-- 1 mcc users 8.1K Apr 13 03:40 CTLCardinality.txt
-rw-r--r-- 1 mcc users 74K Apr 13 03:40 CTLCardinality.xml
-rw-r--r-- 1 mcc users 5.7K Apr 13 03:29 CTLFireability.txt
-rw-r--r-- 1 mcc users 40K Apr 13 03:29 CTLFireability.xml
-rw-r--r-- 1 mcc users 4.2K May 18 16:42 GenericPropertiesDefinition.xml
-rw-r--r-- 1 mcc users 6.4K May 18 16:42 GenericPropertiesVerdict.xml
-rw-r--r-- 1 mcc users 4.2K Apr 22 14:30 LTLCardinality.txt
-rw-r--r-- 1 mcc users 25K Apr 22 14:30 LTLCardinality.xml
-rw-r--r-- 1 mcc users 2.7K Apr 22 14:30 LTLFireability.txt
-rw-r--r-- 1 mcc users 17K Apr 22 14:30 LTLFireability.xml
-rw-r--r-- 1 mcc users 20K Apr 13 06:42 ReachabilityCardinality.txt
-rw-r--r-- 1 mcc users 201K Apr 13 06:42 ReachabilityCardinality.xml
-rw-r--r-- 1 mcc users 13K Apr 13 06:26 ReachabilityFireability.txt
-rw-r--r-- 1 mcc users 93K Apr 13 06:26 ReachabilityFireability.xml
-rw-r--r-- 1 mcc users 1.9K Apr 22 14:30 UpperBounds.txt
-rw-r--r-- 1 mcc users 4.0K Apr 22 14:30 UpperBounds.xml
-rw-r--r-- 1 mcc users 5 May 18 16:42 equiv_pt
-rw-r--r-- 1 mcc users 10 May 18 16:42 instance
-rw-r--r-- 1 mcc users 5 May 18 16:42 iscolored
-rw-r--r-- 1 mcc users 47K May 18 16:42 model.pnml

--------------------
content from stdout:

=== Data for post analysis generated by BenchKit (invocation template)

The expected result is a vector of booleans
BOOL_VECTOR

here is the order used to build the result vector(from text file)
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-00
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-01
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-02
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-03
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-04
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-05
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-06
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-07
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-08
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-09
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-10
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-11
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-12
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-13
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-14
FORMULA_NAME BridgeAndVehicles-COL-V80P50N50-LTLFireability-15

=== Now, execution of the tool begins

BK_START 1717008652122

FORMULA BridgeAndVehicles-COL-V80P50N50-LTLFireability-07 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-COL-V80P50N50-LTLFireability-05 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-COL-V80P50N50-LTLFireability-15 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-COL-V80P50N50-LTLFireability-14 TRUE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 TRUE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-COL-V80P50N50-LTLFireability-08 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-COL-V80P50N50-LTLFireability-06 TRUE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-COL-V80P50N50-LTLFireability-02 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-COL-V80P50N50-LTLFireability-01 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-COL-V80P50N50-LTLFireability-00 TRUE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-COL-V80P50N50-LTLFireability-04 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
FORMULA BridgeAndVehicles-COL-V80P50N50-LTLFireability-09 TRUE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT TOPOLOGICAL STATE_COMPRESSION STUBBORN_SETS USE_NUPN UNFOLDING_TO_PT
[lola] FINAL RESULTS
[lola]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL unknown AGGR
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL true LTL model checker
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL unknown AGGR
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL unknown AGGR
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL unknown AGGR
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola]
[lola] Time elapsed: 2451 secs. Pages in use: 315

BK_STOP 1717011103789

--------------------
content from stderr:

[lola][I] LoLA will run for 3600 seconds at most (--timelimit)
[lola][W] unknown unit in memory specification: using default
[lola][I] MEM LIMIT 5
[lola][I] NET
[lola][I] reading net from model.pnml
[lola][I] input: PNML file (--pnmlnet)
[lola][I] reading pnml
[lola][I] PNML file contains High-Level net
[lola][I] closed net file model.pnml
[lola][I] finished parsing
[lola][I] Reading HL formula in XML format (--xmlformula)
[lola][I] reading formula from LTLFireability.xml
[lola][I] NOTDEADLOCKFREE
[lola][I] nonmoderate token usage
[lola][I] NOTDEADLOCKFREE
[lola][I] NOTDEADLOCKFREE
[lola][I] NOTDEADLOCKFREE
[lola][W] findlow criterion violated for transition 1
[lola][I] Places: 228, Transitions: 8588
[lola][W] findlow criterion violated for transition 2
[lola][W] findlow criterion violated for transition 0
[lola][W] findlow criterion violated for transition 9
[lola][W] findlow criterion violated for transition 5
[lola][W] findlow criterion violated for 6 clusters
[lola][I] Time for checking findlow: 1
[lola][I] Rule S: 0 transitions removed,0 places removed
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 0 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 0 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 5 secs. Pages in use: 0
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 0 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 0 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 10 secs. Pages in use: 0
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 0 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 0 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 15 secs. Pages in use: 0
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 0 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 0 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 20 secs. Pages in use: 0
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 0 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 0 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 25 secs. Pages in use: 0
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 0 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 0 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 30 secs. Pages in use: 0
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 0 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 0 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 35 secs. Pages in use: 0
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 0 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 0 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 40 secs. Pages in use: 0
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I] LAUNCH task # 26 (type EXCL) for 25 BridgeAndVehicles-COL-V80P50N50-LTLFireability-07
[lola][I] time limit : 209 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 26 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-07
[lola][I] result : false
[lola][I] markings : 653
[lola][I] fired transitions : 653
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 0 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 0 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 45 secs. Pages in use: 1
[lola][.] # running tasks: 0 of 4. Visible: 16
[lola][I] LAUNCH task # 41 (type EXCL) for 40 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12
[lola][I] time limit : 221 sec
[lola][I] memory limit: 2000 pages
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 0 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 0 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 1/221 1/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 4503 m, 900 m/sec, 10977 t fired, .
[lola][.]
[lola][.] Time elapsed: 50 secs. Pages in use: 1
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 1 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 0 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 6/221 1/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 46952 m, 8489 m/sec, 133863 t fired, .
[lola][.]
[lola][.] Time elapsed: 55 secs. Pages in use: 1
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] LAUNCH task # 53 (type FNDP) for 19 BridgeAndVehicles-COL-V80P50N50-LTLFireability-05
[lola][I] time limit : 32000000 sec
[lola][I] memory limit: 5 pages
[lola][I] LAUNCH task # 54 (type EQUN) for 19 BridgeAndVehicles-COL-V80P50N50-LTLFireability-05
[lola][I] time limit : 32000000 sec
[lola][I] memory limit: 5 pages
[lola][I] FINISHED task # 53 (type FNDP) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-05
[lola][I] result : true
[lola][I] tried executions : 1
[lola][I] time used : 0
[lola][I] memory pages used : 0
[lola][W] CANCELED task # 54 (type EQUN) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-05 (obsolete)
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 11/236 2/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 184137 m, 27437 m/sec, 538285 t fired, .
[lola][.]
[lola][.] Time elapsed: 60 secs. Pages in use: 2
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] FINISHED task # 54 (type EQUN) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-05
[lola][I] result : unknown
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 16/236 3/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 298806 m, 22933 m/sec, 871015 t fired, .
[lola][.]
[lola][.] Time elapsed: 65 secs. Pages in use: 3
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 21/236 4/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 348443 m, 9927 m/sec, 1063726 t fired, .
[lola][.]
[lola][.] Time elapsed: 70 secs. Pages in use: 4
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 26/236 4/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 433434 m, 16998 m/sec, 1398786 t fired, .
[lola][.]
[lola][.] Time elapsed: 75 secs. Pages in use: 4
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 31/236 5/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 510126 m, 15338 m/sec, 1701799 t fired, .
[lola][.]
[lola][.] Time elapsed: 80 secs. Pages in use: 5
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 36/236 6/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 595664 m, 17107 m/sec, 2028069 t fired, .
[lola][.]
[lola][.] Time elapsed: 85 secs. Pages in use: 6
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 41/236 6/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 640809 m, 9029 m/sec, 2203539 t fired, .
[lola][.]
[lola][.] Time elapsed: 90 secs. Pages in use: 6
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 46/236 7/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 717141 m, 15266 m/sec, 2504455 t fired, .
[lola][.]
[lola][.] Time elapsed: 95 secs. Pages in use: 7
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 51/236 8/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 802310 m, 17033 m/sec, 2841019 t fired, .
[lola][.]
[lola][.] Time elapsed: 100 secs. Pages in use: 8
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 56/236 8/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 890937 m, 17725 m/sec, 3176604 t fired, .
[lola][.]
[lola][.] Time elapsed: 105 secs. Pages in use: 8
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 61/236 9/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 945176 m, 10847 m/sec, 3388186 t fired, .
[lola][.]
[lola][.] Time elapsed: 110 secs. Pages in use: 9
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 66/236 10/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1034917 m, 17948 m/sec, 3742345 t fired, .
[lola][.]
[lola][.] Time elapsed: 115 secs. Pages in use: 10
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 71/236 10/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1104761 m, 13968 m/sec, 4013666 t fired, .
[lola][.]
[lola][.] Time elapsed: 120 secs. Pages in use: 10
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 76/236 11/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1185563 m, 16160 m/sec, 4320193 t fired, .
[lola][.]
[lola][.] Time elapsed: 125 secs. Pages in use: 11
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 81/236 12/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1239286 m, 10744 m/sec, 4530523 t fired, .
[lola][.]
[lola][.] Time elapsed: 130 secs. Pages in use: 12
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 86/236 12/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1321215 m, 16385 m/sec, 4853713 t fired, .
[lola][.]
[lola][.] Time elapsed: 135 secs. Pages in use: 12
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 91/236 13/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1391133 m, 13983 m/sec, 5127189 t fired, .
[lola][.]
[lola][.] Time elapsed: 140 secs. Pages in use: 13
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 96/236 14/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1469861 m, 15745 m/sec, 5421794 t fired, .
[lola][.]
[lola][.] Time elapsed: 145 secs. Pages in use: 14
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 101/236 14/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1520261 m, 10080 m/sec, 5618524 t fired, .
[lola][.]
[lola][.] Time elapsed: 150 secs. Pages in use: 14
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 106/236 15/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1600642 m, 16076 m/sec, 5935564 t fired, .
[lola][.]
[lola][.] Time elapsed: 155 secs. Pages in use: 15
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 111/236 15/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1676961 m, 15263 m/sec, 6237154 t fired, .
[lola][.]
[lola][.] Time elapsed: 160 secs. Pages in use: 15
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 116/236 16/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1755444 m, 15696 m/sec, 6526204 t fired, .
[lola][.]
[lola][.] Time elapsed: 165 secs. Pages in use: 16
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 121/236 17/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1807251 m, 10361 m/sec, 6728582 t fired, .
[lola][.]
[lola][.] Time elapsed: 170 secs. Pages in use: 17
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 126/236 17/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1888857 m, 16321 m/sec, 7050544 t fired, .
[lola][.]
[lola][.] Time elapsed: 175 secs. Pages in use: 17
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 131/236 18/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 1963557 m, 14940 m/sec, 7344943 t fired, .
[lola][.]
[lola][.] Time elapsed: 180 secs. Pages in use: 18
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 136/236 19/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2040788 m, 15446 m/sec, 7627559 t fired, .
[lola][.]
[lola][.] Time elapsed: 185 secs. Pages in use: 19
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 141/236 19/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2096150 m, 11072 m/sec, 7844047 t fired, .
[lola][.]
[lola][.] Time elapsed: 190 secs. Pages in use: 19
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 146/236 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2181148 m, 16999 m/sec, 8179493 t fired, .
[lola][.]
[lola][.] Time elapsed: 195 secs. Pages in use: 20
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 151/236 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2251219 m, 14014 m/sec, 8450140 t fired, .
[lola][.]
[lola][.] Time elapsed: 200 secs. Pages in use: 20
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 156/236 21/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2323990 m, 14554 m/sec, 8718854 t fired, .
[lola][.]
[lola][.] Time elapsed: 205 secs. Pages in use: 21
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 161/236 21/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2380610 m, 11324 m/sec, 8940562 t fired, .
[lola][.]
[lola][.] Time elapsed: 210 secs. Pages in use: 21
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 166/236 22/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2466491 m, 17176 m/sec, 9279881 t fired, .
[lola][.]
[lola][.] Time elapsed: 215 secs. Pages in use: 22
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 171/236 23/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2538387 m, 14379 m/sec, 9553436 t fired, .
[lola][.]
[lola][.] Time elapsed: 220 secs. Pages in use: 23
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 176/236 23/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2605424 m, 13407 m/sec, 9801740 t fired, .
[lola][.]
[lola][.] Time elapsed: 225 secs. Pages in use: 23
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 181/236 24/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2662887 m, 11492 m/sec, 10027020 t fired, .
[lola][.]
[lola][.] Time elapsed: 230 secs. Pages in use: 24
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 186/236 25/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2747576 m, 16937 m/sec, 10361498 t fired, .
[lola][.]
[lola][.] Time elapsed: 235 secs. Pages in use: 25
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 191/236 25/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2826463 m, 15777 m/sec, 10658038 t fired, .
[lola][.]
[lola][.] Time elapsed: 240 secs. Pages in use: 25
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 196/236 26/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2887082 m, 12123 m/sec, 10884111 t fired, .
[lola][.]
[lola][.] Time elapsed: 245 secs. Pages in use: 26
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 201/236 26/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 2952267 m, 13037 m/sec, 11140171 t fired, .
[lola][.]
[lola][.] Time elapsed: 250 secs. Pages in use: 26
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 206/236 27/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 3040648 m, 17676 m/sec, 11489691 t fired, .
[lola][.]
[lola][.] Time elapsed: 255 secs. Pages in use: 27
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 211/236 28/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 3119766 m, 15823 m/sec, 11781194 t fired, .
[lola][.]
[lola][.] Time elapsed: 260 secs. Pages in use: 28
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 216/236 28/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 3165557 m, 9158 m/sec, 11952983 t fired, .
[lola][.]
[lola][.] Time elapsed: 265 secs. Pages in use: 28
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 221/236 29/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 3231583 m, 13205 m/sec, 12212628 t fired, .
[lola][.]
[lola][.] Time elapsed: 270 secs. Pages in use: 29
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 226/236 30/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 3315964 m, 16876 m/sec, 12546036 t fired, .
[lola][.]
[lola][.] Time elapsed: 275 secs. Pages in use: 30
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 231/236 30/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 3390582 m, 14923 m/sec, 12819366 t fired, .
[lola][.]
[lola][.] Time elapsed: 280 secs. Pages in use: 30
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 236/236 31/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 3437871 m, 9457 m/sec, 12996586 t fired, .
[lola][.]
[lola][.] Time elapsed: 285 secs. Pages in use: 31
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][W] CANCELED task # 41 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 (local timeout)
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 1 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 290 secs. Pages in use: 31
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] LAUNCH task # 50 (type EXCL) for 49 BridgeAndVehicles-COL-V80P50N50-LTLFireability-15
[lola][I] time limit : 236 sec
[lola][I] memory limit: 2000 pages
[lola][I] LAUNCH task # 41 (type EXCL) for 40 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12
[lola][I] time limit : 3310 sec
[lola][I] memory limit: 5 pages
[lola][I] FINISHED task # 50 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-15
[lola][I] result : false
[lola][I] markings : 653
[lola][I] fired transitions : 653
[lola][I] time used : 1
[lola][I] memory pages used : 1
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 5/236 2/5 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 122905 m, -662993 m/sec, 357287 t fired, .
[lola][.]
[lola][.] Time elapsed: 295 secs. Pages in use: 33
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 10/236 3/5 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 257226 m, 26864 m/sec, 749623 t fired, .
[lola][.]
[lola][.] Time elapsed: 300 secs. Pages in use: 34
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 15/236 3/5 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 321961 m, 12947 m/sec, 959926 t fired, .
[lola][.]
[lola][.] Time elapsed: 305 secs. Pages in use: 34
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 20/236 4/5 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 393298 m, 14267 m/sec, 1240255 t fired, .
[lola][.]
[lola][.] Time elapsed: 310 secs. Pages in use: 35
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 41 LTL EXCL 25/236 5/5 BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 487158 m, 18772 m/sec, 1611145 t fired, .
[lola][.]
[lola][.] Time elapsed: 315 secs. Pages in use: 36
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] CANCELED task # 41 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-12 (memory limit exceeded)
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL 0 1 0 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 320 secs. Pages in use: 36
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] LAUNCH task # 47 (type EXCL) for 46 BridgeAndVehicles-COL-V80P50N50-LTLFireability-14
[lola][I] time limit : 252 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 47 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-14
[lola][I] result : true
[lola][I] markings : 1
[lola][I] time used : 1
[lola][I] memory pages used : 1
[lola][I] LAUNCH task # 44 (type EXCL) for 43 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13
[lola][I] time limit : 273 sec
[lola][I] memory limit: 2000 pages
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 4/273 2/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 237327 m, 47465 m/sec, 951975 t fired, .
[lola][.]
[lola][.] Time elapsed: 325 secs. Pages in use: 36
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 9/273 4/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 516017 m, 55738 m/sec, 2153484 t fired, .
[lola][.]
[lola][.] Time elapsed: 330 secs. Pages in use: 36
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 14/273 6/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 789414 m, 54679 m/sec, 3352444 t fired, .
[lola][.]
[lola][.] Time elapsed: 335 secs. Pages in use: 37
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 19/273 8/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 1058074 m, 53732 m/sec, 4465779 t fired, .
[lola][.]
[lola][.] Time elapsed: 340 secs. Pages in use: 39
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 24/273 10/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 1298660 m, 48117 m/sec, 5480982 t fired, .
[lola][.]
[lola][.] Time elapsed: 345 secs. Pages in use: 41
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 29/273 12/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 1531829 m, 46633 m/sec, 6465156 t fired, .
[lola][.]
[lola][.] Time elapsed: 350 secs. Pages in use: 43
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 34/273 14/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 1774734 m, 48581 m/sec, 7497387 t fired, .
[lola][.]
[lola][.] Time elapsed: 355 secs. Pages in use: 45
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 39/273 15/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 1968055 m, 38664 m/sec, 8330249 t fired, .
[lola][.]
[lola][.] Time elapsed: 360 secs. Pages in use: 46
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 44/273 16/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 2133791 m, 33147 m/sec, 9019250 t fired, .
[lola][.]
[lola][.] Time elapsed: 365 secs. Pages in use: 47
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 49/273 18/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 2368641 m, 46970 m/sec, 9969704 t fired, .
[lola][.]
[lola][.] Time elapsed: 370 secs. Pages in use: 49
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 54/273 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 2658920 m, 58055 m/sec, 11133229 t fired, .
[lola][.]
[lola][.] Time elapsed: 375 secs. Pages in use: 51
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 59/273 22/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 2945950 m, 57406 m/sec, 12293160 t fired, .
[lola][.]
[lola][.] Time elapsed: 380 secs. Pages in use: 53
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 64/273 24/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 3211429 m, 53095 m/sec, 13425135 t fired, .
[lola][.]
[lola][.] Time elapsed: 385 secs. Pages in use: 55
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 69/273 26/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 3490439 m, 55802 m/sec, 14587612 t fired, .
[lola][.]
[lola][.] Time elapsed: 390 secs. Pages in use: 57
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 74/273 28/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 3761982 m, 54308 m/sec, 15775728 t fired, .
[lola][.]
[lola][.] Time elapsed: 395 secs. Pages in use: 59
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 79/273 30/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 4032244 m, 54052 m/sec, 16928415 t fired, .
[lola][.]
[lola][.] Time elapsed: 400 secs. Pages in use: 61
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 84/273 32/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 4347404 m, 63032 m/sec, 18279797 t fired, .
[lola][.]
[lola][.] Time elapsed: 405 secs. Pages in use: 63
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 89/273 35/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 4633976 m, 57314 m/sec, 19407393 t fired, .
[lola][.]
[lola][.] Time elapsed: 410 secs. Pages in use: 66
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 94/273 37/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 4905105 m, 54225 m/sec, 20504123 t fired, .
[lola][.]
[lola][.] Time elapsed: 415 secs. Pages in use: 68
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 99/273 39/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 5182571 m, 55493 m/sec, 21746867 t fired, .
[lola][.]
[lola][.] Time elapsed: 420 secs. Pages in use: 70
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 104/273 41/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 5461879 m, 55861 m/sec, 22934970 t fired, .
[lola][.]
[lola][.] Time elapsed: 425 secs. Pages in use: 72
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 109/273 42/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 5711836 m, 49991 m/sec, 24007852 t fired, .
[lola][.]
[lola][.] Time elapsed: 430 secs. Pages in use: 73
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 114/273 44/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 5963966 m, 50426 m/sec, 25098182 t fired, .
[lola][.]
[lola][.] Time elapsed: 435 secs. Pages in use: 75
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 119/273 46/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 6230911 m, 53389 m/sec, 26242710 t fired, .
[lola][.]
[lola][.] Time elapsed: 440 secs. Pages in use: 77
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 124/273 48/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 6506548 m, 55127 m/sec, 27423628 t fired, .
[lola][.]
[lola][.] Time elapsed: 445 secs. Pages in use: 79
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 129/273 50/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 6774886 m, 53667 m/sec, 28831375 t fired, .
[lola][.]
[lola][.] Time elapsed: 450 secs. Pages in use: 81
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 134/273 52/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 7042790 m, 53580 m/sec, 29973267 t fired, .
[lola][.]
[lola][.] Time elapsed: 455 secs. Pages in use: 83
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 139/273 54/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 7288553 m, 49152 m/sec, 30983601 t fired, .
[lola][.]
[lola][.] Time elapsed: 460 secs. Pages in use: 85
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 144/273 56/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 7560002 m, 54289 m/sec, 32248183 t fired, .
[lola][.]
[lola][.] Time elapsed: 465 secs. Pages in use: 87
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 149/273 58/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 7861994 m, 60398 m/sec, 33354741 t fired, .
[lola][.]
[lola][.] Time elapsed: 470 secs. Pages in use: 89
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 154/273 60/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 8105906 m, 48782 m/sec, 34549603 t fired, .
[lola][.]
[lola][.] Time elapsed: 475 secs. Pages in use: 91
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 159/273 62/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 8414437 m, 61706 m/sec, 35828350 t fired, .
[lola][.]
[lola][.] Time elapsed: 480 secs. Pages in use: 93
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 164/273 64/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 8665520 m, 50216 m/sec, 37029533 t fired, .
[lola][.]
[lola][.] Time elapsed: 485 secs. Pages in use: 95
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 169/273 66/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 8961369 m, 59169 m/sec, 38335492 t fired, .
[lola][.]
[lola][.] Time elapsed: 490 secs. Pages in use: 97
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 174/273 68/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 9241666 m, 56059 m/sec, 39356225 t fired, .
[lola][.]
[lola][.] Time elapsed: 495 secs. Pages in use: 99
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 179/273 70/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 9489888 m, 49644 m/sec, 40566445 t fired, .
[lola][.]
[lola][.] Time elapsed: 500 secs. Pages in use: 101
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 184/273 72/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 9788384 m, 59699 m/sec, 41899896 t fired, .
[lola][.]
[lola][.] Time elapsed: 505 secs. Pages in use: 103
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 189/273 74/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 10073854 m, 57094 m/sec, 42994946 t fired, .
[lola][.]
[lola][.] Time elapsed: 510 secs. Pages in use: 105
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 194/273 76/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 10313984 m, 48026 m/sec, 44115075 t fired, .
[lola][.]
[lola][.] Time elapsed: 515 secs. Pages in use: 107
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 199/273 78/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 10554439 m, 48091 m/sec, 45209923 t fired, .
[lola][.]
[lola][.] Time elapsed: 520 secs. Pages in use: 109
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 204/273 80/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 10827165 m, 54545 m/sec, 46310518 t fired, .
[lola][.]
[lola][.] Time elapsed: 525 secs. Pages in use: 111
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 209/273 82/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 11100544 m, 54675 m/sec, 47421672 t fired, .
[lola][.]
[lola][.] Time elapsed: 530 secs. Pages in use: 113
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 214/273 84/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 11378408 m, 55572 m/sec, 48711928 t fired, .
[lola][.]
[lola][.] Time elapsed: 535 secs. Pages in use: 115
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 219/273 86/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 11641283 m, 52575 m/sec, 49928182 t fired, .
[lola][.]
[lola][.] Time elapsed: 540 secs. Pages in use: 117
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 224/273 88/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 11904975 m, 52738 m/sec, 51076711 t fired, .
[lola][.]
[lola][.] Time elapsed: 545 secs. Pages in use: 119
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 229/273 90/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 12185957 m, 56196 m/sec, 52274191 t fired, .
[lola][.]
[lola][.] Time elapsed: 550 secs. Pages in use: 121
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 234/273 92/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 12437714 m, 50351 m/sec, 53288440 t fired, .
[lola][.]
[lola][.] Time elapsed: 555 secs. Pages in use: 123
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 239/273 94/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 12706712 m, 53799 m/sec, 54418039 t fired, .
[lola][.]
[lola][.] Time elapsed: 560 secs. Pages in use: 125
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 244/273 96/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 12976405 m, 53938 m/sec, 55572127 t fired, .
[lola][.]
[lola][.] Time elapsed: 565 secs. Pages in use: 127
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 249/273 98/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 13243108 m, 53340 m/sec, 56748078 t fired, .
[lola][.]
[lola][.] Time elapsed: 570 secs. Pages in use: 129
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 254/273 100/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 13494847 m, 50347 m/sec, 57853855 t fired, .
[lola][.]
[lola][.] Time elapsed: 575 secs. Pages in use: 131
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 259/273 102/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 13743572 m, 49745 m/sec, 58915694 t fired, .
[lola][.]
[lola][.] Time elapsed: 580 secs. Pages in use: 133
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 264/273 104/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 14005386 m, 52362 m/sec, 60096122 t fired, .
[lola][.]
[lola][.] Time elapsed: 585 secs. Pages in use: 135
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 44 LTL EXCL 269/273 106/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 14270110 m, 52944 m/sec, 61311039 t fired, .
[lola][.]
[lola][.] Time elapsed: 590 secs. Pages in use: 137
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][W] CANCELED task # 44 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 (local timeout)
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 1 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 595 secs. Pages in use: 139
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] LAUNCH task # 38 (type EXCL) for 37 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11
[lola][I] time limit : 273 sec
[lola][I] memory limit: 2000 pages
[lola][I] LAUNCH task # 44 (type EXCL) for 43 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13
[lola][I] time limit : 3005 sec
[lola][I] memory limit: 5 pages
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 5/273 4/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 376700 m, 75340 m/sec, 1150396 t fired, .
[lola][.] 44 LTL EXCL 5/3005 3/5 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 313404 m, -2791341 m/sec, 1302991 t fired, .
[lola][.]
[lola][.] Time elapsed: 600 secs. Pages in use: 146
[lola][.] # running tasks: 2 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 1 0 1 0 0 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 10/273 8/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 752014 m, 75062 m/sec, 2483255 t fired, .
[lola][.] 44 LTL EXCL 10/250 5/5 BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 624233 m, 62165 m/sec, 2603171 t fired, .
[lola][.]
[lola][.] Time elapsed: 605 secs. Pages in use: 152
[lola][.] # running tasks: 2 of 4. Visible: 16
[lola][I] CANCELED task # 44 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-13 (memory limit exceeded)
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 15/273 12/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 1124849 m, 74567 m/sec, 3805310 t fired, .
[lola][.]
[lola][.] Time elapsed: 610 secs. Pages in use: 153
[lola][.] # running tasks: 2 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 20/273 16/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 1482254 m, 71481 m/sec, 5073327 t fired, .
[lola][.]
[lola][.] Time elapsed: 615 secs. Pages in use: 155
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 25/273 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 1857677 m, 75084 m/sec, 6405068 t fired, .
[lola][.]
[lola][.] Time elapsed: 620 secs. Pages in use: 159
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 30/273 23/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 2212963 m, 71057 m/sec, 7663005 t fired, .
[lola][.]
[lola][.] Time elapsed: 625 secs. Pages in use: 162
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 35/273 27/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 2580251 m, 73457 m/sec, 8965001 t fired, .
[lola][.]
[lola][.] Time elapsed: 630 secs. Pages in use: 166
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 40/273 31/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 2956695 m, 75288 m/sec, 10301006 t fired, .
[lola][.]
[lola][.] Time elapsed: 635 secs. Pages in use: 170
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 45/273 35/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 3313715 m, 71404 m/sec, 11567121 t fired, .
[lola][.]
[lola][.] Time elapsed: 640 secs. Pages in use: 174
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 50/273 39/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 3689897 m, 75236 m/sec, 12902486 t fired, .
[lola][.]
[lola][.] Time elapsed: 645 secs. Pages in use: 178
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 55/273 42/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 4025039 m, 67028 m/sec, 14101075 t fired, .
[lola][.]
[lola][.] Time elapsed: 650 secs. Pages in use: 181
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 60/273 46/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 4378375 m, 70667 m/sec, 15354467 t fired, .
[lola][.]
[lola][.] Time elapsed: 655 secs. Pages in use: 185
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 65/273 50/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 4745955 m, 73516 m/sec, 16657208 t fired, .
[lola][.]
[lola][.] Time elapsed: 660 secs. Pages in use: 189
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 70/273 53/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 5078345 m, 66478 m/sec, 17832813 t fired, .
[lola][.]
[lola][.] Time elapsed: 665 secs. Pages in use: 192
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 75/273 56/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 5415266 m, 67384 m/sec, 19038799 t fired, .
[lola][.]
[lola][.] Time elapsed: 670 secs. Pages in use: 195
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 80/273 60/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 5766240 m, 70194 m/sec, 20283392 t fired, .
[lola][.]
[lola][.] Time elapsed: 675 secs. Pages in use: 199
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 85/273 64/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 6137606 m, 74273 m/sec, 21601464 t fired, .
[lola][.]
[lola][.] Time elapsed: 680 secs. Pages in use: 203
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 90/273 68/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 6511562 m, 74791 m/sec, 22928486 t fired, .
[lola][.]
[lola][.] Time elapsed: 685 secs. Pages in use: 207
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 95/273 71/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 6853287 m, 68345 m/sec, 24136455 t fired, .
[lola][.]
[lola][.] Time elapsed: 690 secs. Pages in use: 210
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 100/273 74/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 7160915 m, 61525 m/sec, 25237056 t fired, .
[lola][.]
[lola][.] Time elapsed: 695 secs. Pages in use: 213
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 105/273 78/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 7495581 m, 66933 m/sec, 26422239 t fired, .
[lola][.]
[lola][.] Time elapsed: 700 secs. Pages in use: 217
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 110/273 81/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 7826770 m, 66237 m/sec, 27592906 t fired, .
[lola][.]
[lola][.] Time elapsed: 705 secs. Pages in use: 220
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 115/273 85/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 8155423 m, 65730 m/sec, 28756066 t fired, .
[lola][.]
[lola][.] Time elapsed: 710 secs. Pages in use: 224
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 120/273 88/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 8485458 m, 66007 m/sec, 29938125 t fired, .
[lola][.]
[lola][.] Time elapsed: 715 secs. Pages in use: 227
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 125/273 92/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 8813160 m, 65540 m/sec, 31096155 t fired, .
[lola][.]
[lola][.] Time elapsed: 720 secs. Pages in use: 231
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 130/273 95/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 9137247 m, 64817 m/sec, 32242522 t fired, .
[lola][.]
[lola][.] Time elapsed: 725 secs. Pages in use: 234
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 135/273 98/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 9467281 m, 66006 m/sec, 33423565 t fired, .
[lola][.]
[lola][.] Time elapsed: 730 secs. Pages in use: 237
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 140/273 102/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 9795758 m, 65695 m/sec, 34586329 t fired, .
[lola][.]
[lola][.] Time elapsed: 735 secs. Pages in use: 241
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 145/273 105/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 10122311 m, 65310 m/sec, 35740442 t fired, .
[lola][.]
[lola][.] Time elapsed: 740 secs. Pages in use: 244
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 150/273 108/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 10450039 m, 65545 m/sec, 36912515 t fired, .
[lola][.]
[lola][.] Time elapsed: 745 secs. Pages in use: 247
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 155/273 112/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 10781657 m, 66323 m/sec, 38088774 t fired, .
[lola][.]
[lola][.] Time elapsed: 750 secs. Pages in use: 251
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 160/273 115/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 11108866 m, 65441 m/sec, 39243557 t fired, .
[lola][.]
[lola][.] Time elapsed: 755 secs. Pages in use: 254
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 165/273 119/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 11434487 m, 65124 m/sec, 40398855 t fired, .
[lola][.]
[lola][.] Time elapsed: 760 secs. Pages in use: 258
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 170/273 122/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 11765424 m, 66187 m/sec, 41581414 t fired, .
[lola][.]
[lola][.] Time elapsed: 765 secs. Pages in use: 261
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 175/273 125/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 12090643 m, 65043 m/sec, 42729923 t fired, .
[lola][.]
[lola][.] Time elapsed: 770 secs. Pages in use: 264
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 180/273 129/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 12418088 m, 65489 m/sec, 43889395 t fired, .
[lola][.]
[lola][.] Time elapsed: 775 secs. Pages in use: 268
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 185/273 132/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 12723484 m, 61079 m/sec, 44982235 t fired, .
[lola][.]
[lola][.] Time elapsed: 780 secs. Pages in use: 271
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 190/273 135/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 13037388 m, 62780 m/sec, 46089564 t fired, .
[lola][.]
[lola][.] Time elapsed: 785 secs. Pages in use: 274
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 195/273 138/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 13352974 m, 63117 m/sec, 47219941 t fired, .
[lola][.]
[lola][.] Time elapsed: 790 secs. Pages in use: 277
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 200/273 142/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 13668987 m, 63202 m/sec, 48337373 t fired, .
[lola][.]
[lola][.] Time elapsed: 795 secs. Pages in use: 281
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 205/273 145/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 13967671 m, 59736 m/sec, 49391155 t fired, .
[lola][.]
[lola][.] Time elapsed: 800 secs. Pages in use: 284
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 210/273 148/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 14287904 m, 64046 m/sec, 50536881 t fired, .
[lola][.]
[lola][.] Time elapsed: 805 secs. Pages in use: 287
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 215/273 151/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 14608980 m, 64215 m/sec, 51670746 t fired, .
[lola][.]
[lola][.] Time elapsed: 810 secs. Pages in use: 290
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 220/273 155/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 14925106 m, 63225 m/sec, 52790279 t fired, .
[lola][.]
[lola][.] Time elapsed: 815 secs. Pages in use: 294
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 225/273 158/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 15237163 m, 62411 m/sec, 53906800 t fired, .
[lola][.]
[lola][.] Time elapsed: 820 secs. Pages in use: 297
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 230/273 161/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 15552122 m, 62991 m/sec, 55004034 t fired, .
[lola][.]
[lola][.] Time elapsed: 825 secs. Pages in use: 300
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 235/273 164/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 15835922 m, 56760 m/sec, 55996142 t fired, .
[lola][.]
[lola][.] Time elapsed: 830 secs. Pages in use: 303
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 240/273 167/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 16123703 m, 57556 m/sec, 57002200 t fired, .
[lola][.]
[lola][.] Time elapsed: 835 secs. Pages in use: 306
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 245/273 170/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 16397492 m, 54757 m/sec, 57959371 t fired, .
[lola][.]
[lola][.] Time elapsed: 840 secs. Pages in use: 309
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 250/273 173/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 16670908 m, 54683 m/sec, 58915418 t fired, .
[lola][.]
[lola][.] Time elapsed: 845 secs. Pages in use: 312
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 38 LTL EXCL 255/273 176/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-11 16962680 m, 58354 m/sec, 59838238 t fired, .
[lola][.]
[lola][.] Time elapsed: 850 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] FINISHED task # 38 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-11
[lola][I] result : true
[lola][I] markings : 17020934
[lola][I] fired transitions : 60067611
[lola][I] time used : 256
[lola][I] memory pages used : 176
[lola][I] LAUNCH task # 35 (type EXCL) for 34 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10
[lola][I] time limit : 274 sec
[lola][I] memory limit: 2000 pages
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 4/274 2/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 213118 m, 42623 m/sec, 894046 t fired, .
[lola][.]
[lola][.] Time elapsed: 855 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 9/274 4/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 526559 m, 62688 m/sec, 2220963 t fired, .
[lola][.]
[lola][.] Time elapsed: 860 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 14/274 6/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 781004 m, 50889 m/sec, 3295327 t fired, .
[lola][.]
[lola][.] Time elapsed: 865 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 19/274 8/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 1055293 m, 54857 m/sec, 4445662 t fired, .
[lola][.]
[lola][.] Time elapsed: 870 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 24/274 10/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 1289122 m, 46765 m/sec, 5424853 t fired, .
[lola][.]
[lola][.] Time elapsed: 875 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 29/274 12/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 1537250 m, 49625 m/sec, 6464515 t fired, .
[lola][.]
[lola][.] Time elapsed: 880 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 34/274 13/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 1750777 m, 42705 m/sec, 7355212 t fired, .
[lola][.]
[lola][.] Time elapsed: 885 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 39/274 15/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 1956356 m, 41115 m/sec, 8205440 t fired, .
[lola][.]
[lola][.] Time elapsed: 890 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 44/274 16/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 2146466 m, 38022 m/sec, 8981899 t fired, .
[lola][.]
[lola][.] Time elapsed: 895 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 49/274 18/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 2417690 m, 54244 m/sec, 10089963 t fired, .
[lola][.]
[lola][.] Time elapsed: 900 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 54/274 21/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 2730933 m, 62648 m/sec, 11359802 t fired, .
[lola][.]
[lola][.] Time elapsed: 905 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 59/274 23/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 3048337 m, 63480 m/sec, 12696623 t fired, .
[lola][.]
[lola][.] Time elapsed: 910 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 64/274 25/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 3342962 m, 58925 m/sec, 13929956 t fired, .
[lola][.]
[lola][.] Time elapsed: 915 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 69/274 27/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 3640375 m, 59482 m/sec, 15181532 t fired, .
[lola][.]
[lola][.] Time elapsed: 920 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 74/274 29/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 3917014 m, 55327 m/sec, 16349661 t fired, .
[lola][.]
[lola][.] Time elapsed: 925 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 79/274 31/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 4204944 m, 57586 m/sec, 17567205 t fired, .
[lola][.]
[lola][.] Time elapsed: 930 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 84/274 34/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 4556045 m, 70220 m/sec, 19067061 t fired, .
[lola][.]
[lola][.] Time elapsed: 935 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 89/274 36/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 4831284 m, 55047 m/sec, 20237591 t fired, .
[lola][.]
[lola][.] Time elapsed: 940 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 94/274 38/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 5118709 m, 57485 m/sec, 21459056 t fired, .
[lola][.]
[lola][.] Time elapsed: 945 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 99/274 40/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 5387164 m, 53691 m/sec, 22603739 t fired, .
[lola][.]
[lola][.] Time elapsed: 950 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 104/274 42/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 5680156 m, 58598 m/sec, 23855321 t fired, .
[lola][.]
[lola][.] Time elapsed: 955 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 109/274 44/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 5942730 m, 52514 m/sec, 24975521 t fired, .
[lola][.]
[lola][.] Time elapsed: 960 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 114/274 46/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 6216538 m, 54761 m/sec, 26144785 t fired, .
[lola][.]
[lola][.] Time elapsed: 965 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 119/274 48/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 6478856 m, 52463 m/sec, 27264387 t fired, .
[lola][.]
[lola][.] Time elapsed: 970 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 124/274 50/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 6764654 m, 57159 m/sec, 28486153 t fired, .
[lola][.]
[lola][.] Time elapsed: 975 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 129/274 52/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 7053916 m, 57852 m/sec, 29724769 t fired, .
[lola][.]
[lola][.] Time elapsed: 980 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 134/274 54/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 7349070 m, 59030 m/sec, 30980454 t fired, .
[lola][.]
[lola][.] Time elapsed: 985 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 139/274 56/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 7612038 m, 52593 m/sec, 32112819 t fired, .
[lola][.]
[lola][.] Time elapsed: 990 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 144/274 58/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 7959177 m, 69427 m/sec, 33609973 t fired, .
[lola][.]
[lola][.] Time elapsed: 995 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 149/274 60/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 8197039 m, 47572 m/sec, 34623734 t fired, .
[lola][.]
[lola][.] Time elapsed: 1000 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 154/274 62/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 8496537 m, 59899 m/sec, 35922634 t fired, .
[lola][.]
[lola][.] Time elapsed: 1005 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 159/274 64/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 8781058 m, 56904 m/sec, 37131996 t fired, .
[lola][.]
[lola][.] Time elapsed: 1010 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 164/274 66/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 9019837 m, 47755 m/sec, 38139595 t fired, .
[lola][.]
[lola][.] Time elapsed: 1015 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 169/274 68/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 9318930 m, 59818 m/sec, 39423502 t fired, .
[lola][.]
[lola][.] Time elapsed: 1020 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 174/274 70/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 9560758 m, 48365 m/sec, 40450014 t fired, .
[lola][.]
[lola][.] Time elapsed: 1025 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 179/274 72/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 9812715 m, 50391 m/sec, 41533102 t fired, .
[lola][.]
[lola][.] Time elapsed: 1030 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 184/274 74/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 10118387 m, 61134 m/sec, 42847451 t fired, .
[lola][.]
[lola][.] Time elapsed: 1035 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 189/274 76/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 10369335 m, 50189 m/sec, 43918451 t fired, .
[lola][.]
[lola][.] Time elapsed: 1040 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 194/274 78/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 10605138 m, 47160 m/sec, 44935484 t fired, .
[lola][.]
[lola][.] Time elapsed: 1045 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 199/274 80/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 10876258 m, 54224 m/sec, 46103611 t fired, .
[lola][.]
[lola][.] Time elapsed: 1050 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 204/274 82/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 11179684 m, 60685 m/sec, 47401893 t fired, .
[lola][.]
[lola][.] Time elapsed: 1055 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 210/274 84/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 11436448 m, 51352 m/sec, 48498294 t fired, .
[lola][.]
[lola][.] Time elapsed: 1061 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 215/274 86/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 11672169 m, 47144 m/sec, 49506709 t fired, .
[lola][.]
[lola][.] Time elapsed: 1066 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 220/274 88/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 11916558 m, 48877 m/sec, 50559353 t fired, .
[lola][.]
[lola][.] Time elapsed: 1071 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 225/274 90/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 12181934 m, 53075 m/sec, 51700279 t fired, .
[lola][.]
[lola][.] Time elapsed: 1076 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 230/274 92/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 12461157 m, 55844 m/sec, 52894474 t fired, .
[lola][.]
[lola][.] Time elapsed: 1081 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 235/274 94/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 12743806 m, 56529 m/sec, 54103374 t fired, .
[lola][.]
[lola][.] Time elapsed: 1086 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 240/274 96/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 13030446 m, 57328 m/sec, 55329780 t fired, .
[lola][.]
[lola][.] Time elapsed: 1091 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 245/274 98/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 13310606 m, 56032 m/sec, 56528829 t fired, .
[lola][.]
[lola][.] Time elapsed: 1096 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 250/274 100/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 13573768 m, 52632 m/sec, 57654026 t fired, .
[lola][.]
[lola][.] Time elapsed: 1101 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 255/274 102/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 13835227 m, 52291 m/sec, 58768507 t fired, .
[lola][.]
[lola][.] Time elapsed: 1106 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 260/274 104/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 14121055 m, 57165 m/sec, 59981620 t fired, .
[lola][.]
[lola][.] Time elapsed: 1111 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 265/274 106/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 14419024 m, 59593 m/sec, 61254461 t fired, .
[lola][.]
[lola][.] Time elapsed: 1116 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 270/274 108/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 14662536 m, 48702 m/sec, 62294928 t fired, .
[lola][.]
[lola][.] Time elapsed: 1121 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][W] CANCELED task # 35 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 (local timeout)
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 1 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1126 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] LAUNCH task # 29 (type EXCL) for 28 BridgeAndVehicles-COL-V80P50N50-LTLFireability-08
[lola][I] time limit : 274 sec
[lola][I] memory limit: 2000 pages
[lola][I] LAUNCH task # 35 (type EXCL) for 34 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10
[lola][I] time limit : 2474 sec
[lola][I] memory limit: 5 pages
[lola][I] FINISHED task # 29 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-08
[lola][I] result : false
[lola][I] markings : 653
[lola][I] fired transitions : 653
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 5/274 3/5 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 320071 m, -2868493 m/sec, 1347290 t fired, .
[lola][.]
[lola][.] Time elapsed: 1131 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 35 LTL EXCL 10/274 5/5 BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 645010 m, 64987 m/sec, 2720503 t fired, .
[lola][.]
[lola][.] Time elapsed: 1136 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] CANCELED task # 35 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-10 (memory limit exceeded)
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ 0 2 0 0 2 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.]
[lola][.] Time elapsed: 1141 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I] LAUNCH task # 23 (type EXCL) for 22 BridgeAndVehicles-COL-V80P50N50-LTLFireability-06
[lola][I] time limit : 307 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 23 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-06
[lola][I] result : true
[lola][I] markings : 4
[lola][I] fired transitions : 3
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I] LAUNCH task # 11 (type EXCL) for 6 BridgeAndVehicles-COL-V80P50N50-LTLFireability-02
[lola][I] time limit : 351 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 11 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-02
[lola][I] result : false
[lola][I] markings : 653
[lola][I] fired transitions : 653
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I] LAUNCH task # 4 (type EXCL) for 3 BridgeAndVehicles-COL-V80P50N50-LTLFireability-01
[lola][I] time limit : 491 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 4 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-01
[lola][I] result : false
[lola][I] markings : 656
[lola][I] fired transitions : 657
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I] LAUNCH task # 1 (type EXCL) for 0 BridgeAndVehicles-COL-V80P50N50-LTLFireability-00
[lola][I] time limit : 614 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 1 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-00
[lola][I] result : true
[lola][I] markings : 1
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I] LAUNCH task # 17 (type EXCL) for 16 BridgeAndVehicles-COL-V80P50N50-LTLFireability-04
[lola][I] time limit : 819 sec
[lola][I] memory limit: 2000 pages
[lola][I] FINISHED task # 17 (type EXCL) for BridgeAndVehicles-COL-V80P50N50-LTLFireability-04
[lola][I] result : false
[lola][I] markings : 654
[lola][I] fired transitions : 655
[lola][I] time used : 0
[lola][I] memory pages used : 1
[lola][I] LAUNCH task # 14 (type EXCL) for 13 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03
[lola][I] time limit : 1229 sec
[lola][I] memory limit: 2000 pages
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 5/1229 1/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 33667 m, 6733 m/sec, 55089 t fired, .
[lola][.]
[lola][.] Time elapsed: 1146 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 10/1229 1/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 73080 m, 7882 m/sec, 119686 t fired, .
[lola][.]
[lola][.] Time elapsed: 1151 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 15/1229 1/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 109244 m, 7232 m/sec, 178902 t fired, .
[lola][.]
[lola][.] Time elapsed: 1156 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 20/1229 2/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 146159 m, 7383 m/sec, 239250 t fired, .
[lola][.]
[lola][.] Time elapsed: 1161 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 25/1229 2/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 179963 m, 6760 m/sec, 294275 t fired, .
[lola][.]
[lola][.] Time elapsed: 1166 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 30/1229 2/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 211882 m, 6383 m/sec, 346193 t fired, .
[lola][.]
[lola][.] Time elapsed: 1171 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 35/1229 3/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 244528 m, 6529 m/sec, 399592 t fired, .
[lola][.]
[lola][.] Time elapsed: 1176 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 40/1229 3/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 276456 m, 6385 m/sec, 451972 t fired, .
[lola][.]
[lola][.] Time elapsed: 1181 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 45/1229 3/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 315263 m, 7761 m/sec, 515808 t fired, .
[lola][.]
[lola][.] Time elapsed: 1186 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 50/1229 4/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 355111 m, 7969 m/sec, 581594 t fired, .
[lola][.]
[lola][.] Time elapsed: 1191 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 55/1229 4/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 393534 m, 7684 m/sec, 644977 t fired, .
[lola][.]
[lola][.] Time elapsed: 1196 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 60/1229 4/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 435809 m, 8455 m/sec, 714609 t fired, .
[lola][.]
[lola][.] Time elapsed: 1201 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 65/1229 5/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 473875 m, 7613 m/sec, 777501 t fired, .
[lola][.]
[lola][.] Time elapsed: 1206 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 70/1229 5/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 518920 m, 9009 m/sec, 851690 t fired, .
[lola][.]
[lola][.] Time elapsed: 1211 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 75/1229 5/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 550500 m, 6316 m/sec, 904324 t fired, .
[lola][.]
[lola][.] Time elapsed: 1216 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 80/1229 6/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 580106 m, 5921 m/sec, 965488 t fired, .
[lola][.]
[lola][.] Time elapsed: 1221 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 85/1229 6/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 602014 m, 4381 m/sec, 1011282 t fired, .
[lola][.]
[lola][.] Time elapsed: 1226 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 90/1229 6/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 620431 m, 3683 m/sec, 1048478 t fired, .
[lola][.]
[lola][.] Time elapsed: 1231 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 95/1229 6/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 643970 m, 4707 m/sec, 1098778 t fired, .
[lola][.]
[lola][.] Time elapsed: 1236 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 100/1229 6/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 662348 m, 3675 m/sec, 1136548 t fired, .
[lola][.]
[lola][.] Time elapsed: 1241 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 105/1229 6/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 685438 m, 4618 m/sec, 1185569 t fired, .
[lola][.]
[lola][.] Time elapsed: 1246 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 110/1229 7/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 708896 m, 4691 m/sec, 1234399 t fired, .
[lola][.]
[lola][.] Time elapsed: 1251 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 115/1229 7/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 731910 m, 4602 m/sec, 1282505 t fired, .
[lola][.]
[lola][.] Time elapsed: 1256 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 120/1229 7/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 754908 m, 4599 m/sec, 1330534 t fired, .
[lola][.]
[lola][.] Time elapsed: 1261 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 125/1229 7/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 776681 m, 4354 m/sec, 1375209 t fired, .
[lola][.]
[lola][.] Time elapsed: 1266 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 130/1229 7/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 801281 m, 4920 m/sec, 1427771 t fired, .
[lola][.]
[lola][.] Time elapsed: 1271 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 135/1229 8/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 823565 m, 4456 m/sec, 1474217 t fired, .
[lola][.]
[lola][.] Time elapsed: 1276 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 140/1229 8/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 844484 m, 4183 m/sec, 1518212 t fired, .
[lola][.]
[lola][.] Time elapsed: 1281 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 145/1229 8/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 863173 m, 3737 m/sec, 1557925 t fired, .
[lola][.]
[lola][.] Time elapsed: 1286 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 150/1229 8/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 877160 m, 2797 m/sec, 1586366 t fired, .
[lola][.]
[lola][.] Time elapsed: 1291 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 155/1229 8/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 901047 m, 4777 m/sec, 1637244 t fired, .
[lola][.]
[lola][.] Time elapsed: 1296 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 160/1229 8/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 911939 m, 2178 m/sec, 1658244 t fired, .
[lola][.]
[lola][.] Time elapsed: 1301 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 165/1229 9/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 935431 m, 4698 m/sec, 1708112 t fired, .
[lola][.]
[lola][.] Time elapsed: 1306 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 170/1229 9/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 956061 m, 4126 m/sec, 1751396 t fired, .
[lola][.]
[lola][.] Time elapsed: 1311 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 175/1229 9/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 975928 m, 3973 m/sec, 1792667 t fired, .
[lola][.]
[lola][.] Time elapsed: 1316 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 180/1229 9/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 995999 m, 4014 m/sec, 1834292 t fired, .
[lola][.]
[lola][.] Time elapsed: 1321 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 185/1229 9/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1016436 m, 4087 m/sec, 1876648 t fired, .
[lola][.]
[lola][.] Time elapsed: 1326 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 190/1229 9/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1037702 m, 4253 m/sec, 1920773 t fired, .
[lola][.]
[lola][.] Time elapsed: 1331 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 195/1229 10/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1059500 m, 4359 m/sec, 1965996 t fired, .
[lola][.]
[lola][.] Time elapsed: 1336 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 200/1229 10/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1083095 m, 4719 m/sec, 2015260 t fired, .
[lola][.]
[lola][.] Time elapsed: 1341 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 205/1229 10/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1102985 m, 3978 m/sec, 2057673 t fired, .
[lola][.]
[lola][.] Time elapsed: 1346 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 210/1229 10/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1126190 m, 4641 m/sec, 2105556 t fired, .
[lola][.]
[lola][.] Time elapsed: 1351 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 215/1229 10/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1149733 m, 4708 m/sec, 2154194 t fired, .
[lola][.]
[lola][.] Time elapsed: 1356 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 220/1229 11/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1172230 m, 4499 m/sec, 2201303 t fired, .
[lola][.]
[lola][.] Time elapsed: 1361 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 225/1229 11/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1194372 m, 4428 m/sec, 2248062 t fired, .
[lola][.]
[lola][.] Time elapsed: 1366 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 230/1229 11/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1216756 m, 4476 m/sec, 2295582 t fired, .
[lola][.]
[lola][.] Time elapsed: 1371 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 235/1229 11/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1237542 m, 4157 m/sec, 2337583 t fired, .
[lola][.]
[lola][.] Time elapsed: 1376 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 240/1229 11/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1261700 m, 4831 m/sec, 2387105 t fired, .
[lola][.]
[lola][.] Time elapsed: 1381 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 245/1229 11/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1281337 m, 3927 m/sec, 2425877 t fired, .
[lola][.]
[lola][.] Time elapsed: 1386 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 250/1229 12/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1303376 m, 4407 m/sec, 2471074 t fired, .
[lola][.]
[lola][.] Time elapsed: 1391 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 255/1229 12/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1328346 m, 4994 m/sec, 2523636 t fired, .
[lola][.]
[lola][.] Time elapsed: 1396 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 260/1229 12/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1355921 m, 5515 m/sec, 2580128 t fired, .
[lola][.]
[lola][.] Time elapsed: 1401 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 265/1229 12/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1370042 m, 2824 m/sec, 2609213 t fired, .
[lola][.]
[lola][.] Time elapsed: 1406 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 270/1229 12/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1389266 m, 3844 m/sec, 2652738 t fired, .
[lola][.]
[lola][.] Time elapsed: 1411 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 275/1229 12/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1401950 m, 2536 m/sec, 2677291 t fired, .
[lola][.]
[lola][.] Time elapsed: 1416 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 280/1229 13/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1418438 m, 3297 m/sec, 2713771 t fired, .
[lola][.]
[lola][.] Time elapsed: 1421 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 285/1229 13/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1430025 m, 2317 m/sec, 2738042 t fired, .
[lola][.]
[lola][.] Time elapsed: 1426 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 290/1229 13/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1445472 m, 3089 m/sec, 2770276 t fired, .
[lola][.]
[lola][.] Time elapsed: 1431 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 295/1229 13/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1463233 m, 3552 m/sec, 2808153 t fired, .
[lola][.]
[lola][.] Time elapsed: 1436 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 300/1229 13/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1478534 m, 3060 m/sec, 2842840 t fired, .
[lola][.]
[lola][.] Time elapsed: 1441 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 305/1229 13/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1488309 m, 1955 m/sec, 2862132 t fired, .
[lola][.]
[lola][.] Time elapsed: 1446 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 310/1229 13/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1505606 m, 3459 m/sec, 2898861 t fired, .
[lola][.]
[lola][.] Time elapsed: 1451 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 315/1229 13/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1522122 m, 3303 m/sec, 2933929 t fired, .
[lola][.]
[lola][.] Time elapsed: 1456 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 320/1229 13/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1536988 m, 2973 m/sec, 2965984 t fired, .
[lola][.]
[lola][.] Time elapsed: 1461 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 325/1229 14/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1550427 m, 2687 m/sec, 2996216 t fired, .
[lola][.]
[lola][.] Time elapsed: 1466 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 330/1229 14/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1562571 m, 2428 m/sec, 3021472 t fired, .
[lola][.]
[lola][.] Time elapsed: 1471 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 335/1229 14/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1573371 m, 2160 m/sec, 3043718 t fired, .
[lola][.]
[lola][.] Time elapsed: 1476 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 340/1229 14/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1588162 m, 2958 m/sec, 3075224 t fired, .
[lola][.]
[lola][.] Time elapsed: 1481 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 345/1229 14/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1602834 m, 2934 m/sec, 3106544 t fired, .
[lola][.]
[lola][.] Time elapsed: 1486 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 350/1229 14/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1617009 m, 2835 m/sec, 3136802 t fired, .
[lola][.]
[lola][.] Time elapsed: 1491 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 355/1229 14/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1631001 m, 2798 m/sec, 3166747 t fired, .
[lola][.]
[lola][.] Time elapsed: 1496 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 360/1229 14/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1647028 m, 3205 m/sec, 3201342 t fired, .
[lola][.]
[lola][.] Time elapsed: 1501 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 365/1229 15/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1664255 m, 3445 m/sec, 3238981 t fired, .
[lola][.]
[lola][.] Time elapsed: 1506 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 370/1229 15/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1679549 m, 3058 m/sec, 3270370 t fired, .
[lola][.]
[lola][.] Time elapsed: 1511 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 375/1229 15/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1692863 m, 2662 m/sec, 3299049 t fired, .
[lola][.]
[lola][.] Time elapsed: 1516 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 380/1229 15/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1710610 m, 3549 m/sec, 3337144 t fired, .
[lola][.]
[lola][.] Time elapsed: 1521 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 385/1229 15/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1726442 m, 3166 m/sec, 3371794 t fired, .
[lola][.]
[lola][.] Time elapsed: 1526 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 390/1229 15/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1742047 m, 3121 m/sec, 3405001 t fired, .
[lola][.]
[lola][.] Time elapsed: 1531 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 395/1229 15/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1757288 m, 3048 m/sec, 3437741 t fired, .
[lola][.]
[lola][.] Time elapsed: 1536 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 400/1229 15/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1770086 m, 2559 m/sec, 3463900 t fired, .
[lola][.]
[lola][.] Time elapsed: 1541 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 405/1229 15/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1782129 m, 2408 m/sec, 3489818 t fired, .
[lola][.]
[lola][.] Time elapsed: 1546 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 410/1229 16/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1795195 m, 2613 m/sec, 3516743 t fired, .
[lola][.]
[lola][.] Time elapsed: 1551 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 415/1229 16/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1809785 m, 2918 m/sec, 3549675 t fired, .
[lola][.]
[lola][.] Time elapsed: 1556 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 420/1229 16/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1823611 m, 2765 m/sec, 3578886 t fired, .
[lola][.]
[lola][.] Time elapsed: 1561 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 425/1229 16/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1836051 m, 2488 m/sec, 3604186 t fired, .
[lola][.]
[lola][.] Time elapsed: 1566 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 430/1229 16/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1844957 m, 1781 m/sec, 3623921 t fired, .
[lola][.]
[lola][.] Time elapsed: 1571 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 435/1229 16/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1862055 m, 3419 m/sec, 3659338 t fired, .
[lola][.]
[lola][.] Time elapsed: 1576 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 440/1229 16/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1876517 m, 2892 m/sec, 3692529 t fired, .
[lola][.]
[lola][.] Time elapsed: 1581 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 445/1229 16/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1888969 m, 2490 m/sec, 3716925 t fired, .
[lola][.]
[lola][.] Time elapsed: 1586 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 450/1229 17/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1907183 m, 3642 m/sec, 3757952 t fired, .
[lola][.]
[lola][.] Time elapsed: 1591 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 455/1229 17/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1916524 m, 1868 m/sec, 3775871 t fired, .
[lola][.]
[lola][.] Time elapsed: 1596 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 460/1229 17/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1935218 m, 3738 m/sec, 3817010 t fired, .
[lola][.]
[lola][.] Time elapsed: 1601 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 465/1229 17/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1943777 m, 1711 m/sec, 3834008 t fired, .
[lola][.]
[lola][.] Time elapsed: 1606 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 470/1229 17/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1963328 m, 3910 m/sec, 3876550 t fired, .
[lola][.]
[lola][.] Time elapsed: 1611 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 475/1229 17/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1971520 m, 1638 m/sec, 3893162 t fired, .
[lola][.]
[lola][.] Time elapsed: 1616 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 480/1229 17/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1991711 m, 4038 m/sec, 3936893 t fired, .
[lola][.]
[lola][.] Time elapsed: 1621 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 485/1229 17/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 1999508 m, 1559 m/sec, 3952762 t fired, .
[lola][.]
[lola][.] Time elapsed: 1626 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 490/1229 17/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2018773 m, 3853 m/sec, 3995409 t fired, .
[lola][.]
[lola][.] Time elapsed: 1631 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 495/1229 17/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2028328 m, 1911 m/sec, 4014111 t fired, .
[lola][.]
[lola][.] Time elapsed: 1636 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 500/1229 18/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2048631 m, 4060 m/sec, 4058891 t fired, .
[lola][.]
[lola][.] Time elapsed: 1641 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 505/1229 18/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2058087 m, 1891 m/sec, 4077537 t fired, .
[lola][.]
[lola][.] Time elapsed: 1646 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 510/1229 18/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2079754 m, 4333 m/sec, 4127020 t fired, .
[lola][.]
[lola][.] Time elapsed: 1651 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 515/1229 18/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2095896 m, 3228 m/sec, 4159521 t fired, .
[lola][.]
[lola][.] Time elapsed: 1656 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 520/1229 18/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2109384 m, 2697 m/sec, 4190029 t fired, .
[lola][.]
[lola][.] Time elapsed: 1661 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 525/1229 18/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2126530 m, 3429 m/sec, 4224704 t fired, .
[lola][.]
[lola][.] Time elapsed: 1666 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 530/1229 18/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2134857 m, 1665 m/sec, 4243216 t fired, .
[lola][.]
[lola][.] Time elapsed: 1671 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 535/1229 19/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2157590 m, 4546 m/sec, 4290725 t fired, .
[lola][.]
[lola][.] Time elapsed: 1676 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 540/1229 19/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2165054 m, 1492 m/sec, 4307697 t fired, .
[lola][.]
[lola][.] Time elapsed: 1681 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 545/1229 19/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2187181 m, 4425 m/sec, 4355135 t fired, .
[lola][.]
[lola][.] Time elapsed: 1686 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 550/1229 19/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2195011 m, 1566 m/sec, 4371295 t fired, .
[lola][.]
[lola][.] Time elapsed: 1691 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 555/1229 19/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2213549 m, 3707 m/sec, 4413521 t fired, .
[lola][.]
[lola][.] Time elapsed: 1696 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 560/1229 19/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2225014 m, 2293 m/sec, 4434595 t fired, .
[lola][.]
[lola][.] Time elapsed: 1701 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 565/1229 19/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2231737 m, 1344 m/sec, 4449589 t fired, .
[lola][.]
[lola][.] Time elapsed: 1706 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 570/1229 19/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2253632 m, 4379 m/sec, 4497192 t fired, .
[lola][.]
[lola][.] Time elapsed: 1711 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 575/1229 19/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2262092 m, 1692 m/sec, 4514081 t fired, .
[lola][.]
[lola][.] Time elapsed: 1716 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 580/1229 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2281090 m, 3799 m/sec, 4557289 t fired, .
[lola][.]
[lola][.] Time elapsed: 1721 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 585/1229 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2293814 m, 2544 m/sec, 4581071 t fired, .
[lola][.]
[lola][.] Time elapsed: 1726 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 590/1229 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2301111 m, 1459 m/sec, 4597448 t fired, .
[lola][.]
[lola][.] Time elapsed: 1731 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 595/1229 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2322939 m, 4365 m/sec, 4645479 t fired, .
[lola][.]
[lola][.] Time elapsed: 1736 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 600/1229 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2331709 m, 1754 m/sec, 4662193 t fired, .
[lola][.]
[lola][.] Time elapsed: 1741 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 605/1229 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2340071 m, 1672 m/sec, 4680441 t fired, .
[lola][.]
[lola][.] Time elapsed: 1746 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 610/1229 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2363355 m, 4656 m/sec, 4729757 t fired, .
[lola][.]
[lola][.] Time elapsed: 1751 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 615/1229 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2371234 m, 1575 m/sec, 4746942 t fired, .
[lola][.]
[lola][.] Time elapsed: 1756 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 620/1229 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2394049 m, 4563 m/sec, 4798405 t fired, .
[lola][.]
[lola][.] Time elapsed: 1761 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 625/1229 20/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2404916 m, 2173 m/sec, 4817977 t fired, .
[lola][.]
[lola][.] Time elapsed: 1766 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 630/1229 21/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2418010 m, 2618 m/sec, 4848311 t fired, .
[lola][.]
[lola][.] Time elapsed: 1771 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 635/1229 21/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2436868 m, 3771 m/sec, 4885776 t fired, .
[lola][.]
[lola][.] Time elapsed: 1776 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 640/1229 21/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2452640 m, 3154 m/sec, 4915933 t fired, .
[lola][.]
[lola][.] Time elapsed: 1781 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 645/1229 21/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2462886 m, 2049 m/sec, 4940222 t fired, .
[lola][.]
[lola][.] Time elapsed: 1786 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 650/1229 21/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2475883 m, 2599 m/sec, 4971384 t fired, .
[lola][.]
[lola][.] Time elapsed: 1791 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 655/1229 21/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2500217 m, 4866 m/sec, 5024886 t fired, .
[lola][.]
[lola][.] Time elapsed: 1796 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 660/1229 21/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2510017 m, 1960 m/sec, 5043746 t fired, .
[lola][.]
[lola][.] Time elapsed: 1801 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 665/1229 21/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2516824 m, 1361 m/sec, 5059388 t fired, .
[lola][.]
[lola][.] Time elapsed: 1806 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 670/1229 22/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2535473 m, 3729 m/sec, 5098637 t fired, .
[lola][.]
[lola][.] Time elapsed: 1811 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 675/1229 22/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2542668 m, 1439 m/sec, 5115151 t fired, .
[lola][.]
[lola][.] Time elapsed: 1816 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 680/1229 22/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2560524 m, 3571 m/sec, 5153113 t fired, .
[lola][.]
[lola][.] Time elapsed: 1821 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 685/1229 22/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2567061 m, 1307 m/sec, 5167704 t fired, .
[lola][.]
[lola][.] Time elapsed: 1826 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 690/1229 22/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2581366 m, 2861 m/sec, 5200593 t fired, .
[lola][.]
[lola][.] Time elapsed: 1831 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 695/1229 22/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2590285 m, 1783 m/sec, 5217749 t fired, .
[lola][.]
[lola][.] Time elapsed: 1836 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 700/1229 22/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2597127 m, 1368 m/sec, 5233211 t fired, .
[lola][.]
[lola][.] Time elapsed: 1841 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 705/1229 22/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2613259 m, 3226 m/sec, 5267244 t fired, .
[lola][.]
[lola][.] Time elapsed: 1846 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 710/1229 22/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2619716 m, 1291 m/sec, 5282032 t fired, .
[lola][.]
[lola][.] Time elapsed: 1851 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-13: LTL 0 0 0 0 1 0 1 0
[lola][.]
[lola][.]  TASK CATEGORY TYPE TIME/TLIMIT MEM PG/PGLIMIT FORMULA STATUS
[lola][.] 14 LTL EXCL 715/1229 22/2000 BridgeAndVehicles-COL-V80P50N50-LTLFireability-03 2636548 m, 3366 m/sec, 5317749 t fired, .
[lola][.]
[lola][.] Time elapsed: 1856 secs. Pages in use: 315
[lola][.] # running tasks: 1 of 4. Visible: 16
[lola][I]  FINISHED FORMULA: CATEGORY VALUE PRODUCED BY
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-00: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-01: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-02: CONJ false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-04: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-05: AG false findpath
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-06: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-07: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-08: LTL false LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-11: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-14: LTL true LTL model checker
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-15: LTL false LTL model checker
[lola][.]
[lola][.]  PENDING FORMULAS: CATEGORY IDL ACT RUN SUS FIN C/T C/M OBS
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-03: LTL 0 0 1 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-09: LTL 0 1 0 0 1 0 0 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-10: LTL 0 0 0 0 1 0 1 0
[lola][.] BridgeAndVehicles-COL-V80P50N50-LTLFireability-12: LTL 0 0 0 0 1 0 1 0

========== file over 1MB has been truncated ======
retrieve it from the run archives if needed

Sequence of Actions to be Executed by the VM

This is useful if one wants to reexecute the tool in the VM from the submitted image disk.

set -x
# this is for BenchKit: configuration of major elements for the test
export BK_INPUT="BridgeAndVehicles-COL-V80P50N50"
export BK_EXAMINATION="LTLFireability"
export BK_TOOL="lola"
export BK_RESULT_DIR="/tmp/BK_RESULTS/OUTPUTS"
export BK_TIME_CONFINEMENT="3600"
export BK_MEMORY_CONFINEMENT="16384"
export BK_BIN_PATH="/home/mcc/BenchKit/bin/"

# this is specific to your benchmark or test

export BIN_DIR="$HOME/BenchKit/bin"

# remove the execution directoty if it exists (to avoid increse of .vmdk images)
if [ -d execution ] ; then
rm -rf execution
fi

# this is for BenchKit: explicit launching of the test
echo "====================================================================="
echo " Generated by BenchKit 2-5568"
echo " Executing tool lola"
echo " Input is BridgeAndVehicles-COL-V80P50N50, examination is LTLFireability"
echo " Time confinement is $BK_TIME_CONFINEMENT seconds"
echo " Memory confinement is 16384 MBytes"
echo " Number of cores is 4"
echo " Run identifier is r049-tajo-171620400200156"
echo "====================================================================="
echo
echo "--------------------"
echo "preparation of the directory to be used:"

tar xzf /home/mcc/BenchKit/INPUTS/BridgeAndVehicles-COL-V80P50N50.tgz
mv BridgeAndVehicles-COL-V80P50N50 execution
cd execution
if [ "LTLFireability" = "ReachabilityDeadlock" ] || [ "LTLFireability" = "UpperBounds" ] || [ "LTLFireability" = "QuasiLiveness" ] || [ "LTLFireability" = "StableMarking" ] || [ "LTLFireability" = "Liveness" ] || [ "LTLFireability" = "OneSafe" ] || [ "LTLFireability" = "StateSpace" ]; then
rm -f GenericPropertiesVerdict.xml
fi
pwd
ls -lh

echo
echo "--------------------"
echo "content from stdout:"
echo
echo "=== Data for post analysis generated by BenchKit (invocation template)"
echo
if [ "LTLFireability" = "UpperBounds" ] ; then
echo "The expected result is a vector of positive values"
echo NUM_VECTOR
elif [ "LTLFireability" != "StateSpace" ] ; then
echo "The expected result is a vector of booleans"
echo BOOL_VECTOR
else
echo "no data necessary for post analysis"
fi
echo
if [ -f "LTLFireability.txt" ] ; then
echo "here is the order used to build the result vector(from text file)"
for x in $(grep Property LTLFireability.txt | cut -d ' ' -f 2 | sort -u) ; do
echo "FORMULA_NAME $x"
done
elif [ -f "LTLFireability.xml" ] ; then # for cunf (txt files deleted;-)
echo echo "here is the order used to build the result vector(from xml file)"
for x in $(grep '' LTLFireability.xml | cut -d '>' -f 2 | cut -d '<' -f 1 | sort -u) ; do
echo "FORMULA_NAME $x"
done
elif [ "LTLFireability" = "ReachabilityDeadlock" ] || [ "LTLFireability" = "QuasiLiveness" ] || [ "LTLFireability" = "StableMarking" ] || [ "LTLFireability" = "Liveness" ] || [ "LTLFireability" = "OneSafe" ] ; then
echo "FORMULA_NAME LTLFireability"
fi
echo
echo "=== Now, execution of the tool begins"
echo
echo -n "BK_START "
date -u +%s%3N
echo
timeout -s 9 $BK_TIME_CONFINEMENT bash -c "/home/mcc/BenchKit/BenchKit_head.sh 2> STDERR ; echo ; echo -n \"BK_STOP \" ; date -u +%s%3N"
if [ $? -eq 137 ] ; then
echo
echo "BK_TIME_CONFINEMENT_REACHED"
fi
echo
echo "--------------------"
echo "content from stderr:"
echo
cat STDERR ;