fond
Model Checking Contest 2018
8th edition, Bratislava, Slovakia, June 26, 2018
Execution of r222-ebro-152732363900018
Last Updated
June 26, 2018

About the Execution of Irma.full for BART-PT-002

Execution Summary
Max Memory
Used (MB)
Time wait (ms) CPU Usage (ms) I/O Wait (ms) Computed Result Execution
Status
435.690 44802.00 6592.00 149.10 FTFFFFFFFFFTFFFF normal

Execution Chart

We display below the execution chart for this examination (boot time has been removed).

Trace from the execution

Waiting for the VM to be ready (probing ssh)
.....................
/home/mcc/execution
total 1.7M
-rw-r--r-- 1 mcc users 82K May 15 18:54 CTLCardinality.txt
-rw-r--r-- 1 mcc users 201K May 15 18:54 CTLCardinality.xml
-rw-r--r-- 1 mcc users 55K May 15 18:54 CTLFireability.txt
-rw-r--r-- 1 mcc users 148K May 15 18:54 CTLFireability.xml
-rw-r--r-- 1 mcc users 4.0K May 15 18:49 GenericPropertiesDefinition.xml
-rw-r--r-- 1 mcc users 6.1K May 15 18:49 GenericPropertiesVerdict.xml
-rw-r--r-- 1 mcc users 34K May 26 09:26 LTLCardinality.txt
-rw-r--r-- 1 mcc users 84K May 26 09:26 LTLCardinality.xml
-rw-r--r-- 1 mcc users 19K May 26 09:26 LTLFireability.txt
-rw-r--r-- 1 mcc users 47K May 26 09:26 LTLFireability.xml
-rw-r--r-- 1 mcc users 44K May 15 18:54 ReachabilityCardinality.txt
-rw-r--r-- 1 mcc users 110K May 15 18:54 ReachabilityCardinality.xml
-rw-r--r-- 1 mcc users 102 May 15 18:54 ReachabilityDeadlock.txt
-rw-r--r-- 1 mcc users 340 May 15 18:54 ReachabilityDeadlock.xml
-rw-r--r-- 1 mcc users 64K May 15 18:54 ReachabilityFireability.txt
-rw-r--r-- 1 mcc users 169K May 15 18:54 ReachabilityFireability.xml
-rw-r--r-- 1 mcc users 14K May 15 18:54 UpperBounds.txt
-rw-r--r-- 1 mcc users 27K May 15 18:54 UpperBounds.xml
-rw-r--r-- 1 mcc users 5 May 15 18:49 equiv_col
-rw-r--r-- 1 mcc users 4 May 15 18:49 instance
-rw-r--r-- 1 mcc users 6 May 15 18:49 iscolored
-rw-r--r-- 1 mcc users 506K May 15 18:49 model.pnml
=====================================================================
Generated by BenchKit 2-3637
Executing tool irma4mcc-full
Input is BART-PT-002, examination is LTLFireability
Time confinement is 3600 seconds
Memory confinement is 16384 MBytes
Number of cores is 4
Run identifier is r222-ebro-152732363900018
=====================================================================


--------------------
content from stdout:

=== Data for post analysis generated by BenchKit (invocation template)

The expected result is a vector of booleans
BOOL_VECTOR

here is the order used to build the result vector(from text file)
FORMULA_NAME BART-PT-002-LTLFireability-00
FORMULA_NAME BART-PT-002-LTLFireability-01
FORMULA_NAME BART-PT-002-LTLFireability-02
FORMULA_NAME BART-PT-002-LTLFireability-03
FORMULA_NAME BART-PT-002-LTLFireability-04
FORMULA_NAME BART-PT-002-LTLFireability-05
FORMULA_NAME BART-PT-002-LTLFireability-06
FORMULA_NAME BART-PT-002-LTLFireability-07
FORMULA_NAME BART-PT-002-LTLFireability-08
FORMULA_NAME BART-PT-002-LTLFireability-09
FORMULA_NAME BART-PT-002-LTLFireability-10
FORMULA_NAME BART-PT-002-LTLFireability-11
FORMULA_NAME BART-PT-002-LTLFireability-12
FORMULA_NAME BART-PT-002-LTLFireability-13
FORMULA_NAME BART-PT-002-LTLFireability-14
FORMULA_NAME BART-PT-002-LTLFireability-15

=== Now, execution of the tool begins

BK_START 1527499445294


BK_STOP 1527499490096

--------------------
content from stderr:

Prefix is 65b80f64.
Reading known information in /usr/share/mcc4mcc/65b80f64-known.json.
Reading learned information in /usr/share/mcc4mcc/65b80f64-learned.json.
Reading value translations in /usr/share/mcc4mcc/65b80f64-values.json.
Using directory /home/mcc/execution for input, as it contains a model.pnml file.
Using BART-PT-002 as instance name.
Using BART as model name.
Using algorithm or tool bmdt.
Model characteristics are: {'Examination': 'LTLFireability', 'Place/Transition': True, 'Colored': True, 'Relative-Time': 1, 'Relative-Memory': 1, 'Ordinary': True, 'Simple Free Choice': False, 'Extended Free Choice': False, 'State Machine': False, 'Marked Graph': False, 'Connected': True, 'Strongly Connected': True, 'Source Place': False, 'Sink Place': False, 'Source Transition': False, 'Sink Transition': False, 'Loop Free': False, 'Conservative': True, 'Sub-Conservative': True, 'Nested Units': False, 'Safe': True, 'Deadlock': False, 'Reversible': None, 'Quasi Live': None, 'Live': None}.
Known tools are: [{'Time': 916, 'Memory': 131.2, 'Tool': 'lola'}].
Learned tools are: [{'Tool': 'marcie'}].
LTLFireability lola BART-PT-002...

Time: 3600 - MCC
----- Start make prepare stdout -----
----- Start make prepare stderr -----
===========================================================================================
BART-PT-002: translating PT Petri net model.pnml into LoLA format
===========================================================================================
translating PT Petri net complete


checking for too many tokens
===========================================================================================
BART-PT-002: translating PT formula LTLFireability into LoLA format
===========================================================================================
translating formula complete
touch formulae;
----- Start make result stdout -----
----- Start make result stderr -----
LTLFireability @ BART-PT-002 @ 3540 seconds
----- Start make result stderr -----
----- Start make result stdout -----
lola: LoLA will run for 3540 seconds at most (--timelimit)
lola: NET
lola: reading net from model.pnml.lola
lola: finished parsing
lola: closed net file model.pnml.lola
lola: 878/65536 symbol table entries, 5 collisions
lola: preprocessing...
lola: finding significant places
lola: 474 places, 404 transitions, 262 significant places
lola: computing forward-conflicting sets
lola: computing back-conflicting sets
lola: 343 transition conflict sets
lola: TASK
lola: reading formula from BART-PT-002-LTLFireability.task
lola: A ((X (X (G ((FIREABLE(TrainStop_1) OR FIREABLE(TrainStop_2))))) U G (G (X ((FIREABLE(TrainDecc_2_1_3_4_2_1_6) OR FIREABLE(TrainDecc_2_2_3_4_2_1_6) OR FIREABLE(TrainDecc_2_1_3_5_3_2_6) OR FIREABLE(TrainDecc_2_2_3_5_3_2_6) OR FIREABLE(TrainDecc_3_1_6_7_4_3_10) OR FIREABLE(TrainDecc_3_2_6_7_4_3_10) OR FIREABLE(TrainDecc_3_1_6_8_5_4_10) OR FIREABLE(TrainDecc_3_2_6_8_5_4_10) OR FIREABLE(TrainDecc_3_1_6_9_6_5_10) OR FIREABLE(TrainDecc_3_2_6_9_6_5_10) OR FIREABLE(TrainDecc_4_1_10_11_7_6_15) OR FIREABLE(TrainDecc_4_2_10_11_7_6_15) OR FIREABLE(TrainDecc_4_1_10_12_8_7_15) OR FIREABLE(TrainDecc_4_2_10_12_8_7_15) OR FIREABLE(TrainDecc_4_1_10_13_9_8_15) OR FIREABLE(TrainDecc_4_2_10_13_9_8_15) OR FIREABLE(TrainDecc_4_1_10_14_10_9_15) OR FIREABLE(TrainDecc_4_2_10_14_10_9_15))))))) : A (X (F ((FIREABLE(TrainStop_1) OR FIREABLE(TrainStop_2))))) : A (G (F (X (X (X ((FIREABLE(TrainDecc_2_1_3_4_2_1_6) OR FIREABLE(TrainDecc_2_2_3_4_2_1_6) OR FIREABLE(TrainDecc_2_1_3_5_3_2_6) OR FIREABLE(TrainDecc_2_2_3_5_3_2_6) OR FIREABLE(TrainDecc_3_1_6_7_4_3_10) OR FIREABLE(TrainDecc_3_2_6_7_4_3_10) OR FIREABLE(TrainDecc_3_1_6_8_5_4_10) OR FIREABLE(TrainDecc_3_2_6_8_5_4_10) OR FIREABLE(TrainDecc_3_1_6_9_6_5_10) OR FIREABLE(TrainDecc_3_2_6_9_6_5_10) OR FIREABLE(TrainDecc_4_1_10_11_7_6_15) OR FIREABLE(TrainDecc_4_2_10_11_7_6_15) OR FIREABLE(TrainDecc_4_1_10_12_8_7_15) OR FIREABLE(TrainDecc_4_2_10_12_8_7_15) OR FIREABLE(TrainDecc_4_1_10_13_9_8_15) OR FIREABLE(TrainDecc_4_2_10_13_9_8_15) OR FIREABLE(TrainDecc_4_1_10_14_10_9_15) OR FIREABLE(TrainDecc_4_2_10_14_10_9_15)))))))) : A (G (G ((FIREABLE(TrainAcc_1_1_6_5_4_3) OR FIREABLE(TrainAcc_1_2_6_5_4_3) OR FIREABLE(TrainAcc_1_1_7_6_5_3) OR FIREABLE(TrainAcc_1_2_7_6_5_3) OR FIREABLE(TrainAcc_1_1_8_7_6_3) OR FIREABLE(TrainAcc_1_2_8_7_6_3) OR FIREABLE(TrainAcc_1_1_9_8_7_3) OR FIREABLE(TrainAcc_1_2_9_8_7_3) OR FIREABLE(TrainAcc_1_1_10_9_8_3) OR FIREABLE(TrainAcc_1_2_10_9_8_3) OR FIREABLE(TrainAcc_1_1_11_10_9_3) OR FIREABLE(TrainAcc_1_2_11_10_9_3) OR FIREABLE(TrainAcc_1_1_12_11_10_3) OR FIREABLE(TrainAcc_1_2_12_11_10_3) OR FIREABLE(TrainAcc_1_1_13_12_11_3) OR FIREABLE(TrainAcc_1_2_13_12_11_3) OR FIREABLE(TrainAcc_1_1_14_13_12_3) OR FIREABLE(TrainAcc_1_2_14_13_12_3) OR FIREABLE(TrainAcc_1_1_15_14_13_3) OR FIREABLE(TrainAcc_1_2_15_14_13_3) OR FIREABLE(TrainAcc_1_1_16_15_14_3) OR FIREABLE(TrainAcc_1_2_16_15_14_3) OR FIREABLE(TrainAcc_1_1_17_16_15_3) OR FIREABLE(TrainAcc_1_2_17_16_15_3) OR FIREABLE(TrainAcc_1_1_18_17_16_3) OR FIREABLE(TrainAcc_1_2_18_17_16_3) OR FIREABLE(TrainAcc_1_1_19_18_17_3) OR FIREABLE(TrainAcc_1_2_19_18_17_3) OR FIREABLE(TrainAcc_1_1_20_19_18_3) OR FIREABLE(TrainAcc_1_2_20_19_18_3) OR FIREABLE(TrainAcc_1_1_21_20_19_3) OR FIREABLE(TrainAcc_1_2_21_20_19_3) OR FIREABLE(TrainAcc_1_1_22_21_20_3) OR FIREABLE(TrainAcc_1_2_22_21_20_3) OR FIREABLE(TrainAcc_1_1_23_22_21_3) OR FIREABLE(TrainAcc_1_2_23_22_21_3) OR FIREABLE(TrainAcc_1_1_24_23_22_3) OR FIREABLE(TrainAcc_1_2_24_23_22_3) OR FIREABLE(TrainAcc_1_1_25_24_23_3) OR FIREABLE(TrainAcc_1_2_25_24_23_3) OR FIREABLE(TrainAcc_1_1_26_25_24_3) OR FIREABLE(TrainAcc_1_2_26_25_24_3) OR FIREABLE(TrainAcc_1_1_27_26_25_3) OR FIREABLE(TrainAcc_1_2_27_26_25_3) OR FIREABLE(TrainAcc_1_1_28_27_26_3) OR FIREABLE(TrainAcc_1_2_28_27_26_3) OR FIREABLE(TrainAcc_1_1_29_28_27_3) OR FIREABLE(TrainAcc_1_2_29_28_27_3) OR FIREABLE(TrainAcc_1_1_30_29_28_3) OR FIREABLE(TrainAcc_1_2_30_29_28_3) OR FIREABLE(TrainAcc_1_1_31_30_29_3) OR FIREABLE(TrainAcc_1_2_31_30_29_3) OR FIREABLE(TrainAcc_1_1_32_31_30_3) OR FIREABLE(TrainAcc_1_2_32_31_30_3) OR FIREABLE(TrainAcc_1_1_33_32_31_3) OR FIREABLE(TrainAcc_1_2_33_32_31_3) OR FIREABLE(TrainAcc_1_1_34_33_32_3) OR FIREABLE(TrainAcc_1_2_34_33_32_3) OR FIREABLE(TrainAcc_1_1_35_34_33_3) OR FIREABLE(TrainAcc_1_2_35_34_33_3) OR FIREABLE(TrainAcc_1_1_36_35_34_3) OR FIREABLE(TrainAcc_1_2_36_35_34_3) OR FIREABLE(TrainAcc_1_1_37_36_35_3) OR FIREABLE(TrainAcc_1_2_37_36_35_3) OR FIREABLE(TrainAcc_1_1_38_37_36_3) OR FIREABLE(TrainAcc_1_2_38_37_36_3) OR FIREABLE(TrainAcc_1_1_39_38_37_3) OR FIREABLE(TrainAcc_1_2_39_38_37_3) OR FIREABLE(TrainAcc_1_1_40_39_38_3) OR FIREABLE(TrainAcc_1_2_40_39_38_3) OR FIREABLE(TrainAcc_2_1_10_8_7_6) OR FIREABLE(TrainAcc_2_2_10_8_7_6) OR FIREABLE(TrainAcc_2_1_11_9_8_6) OR FIREABLE(TrainAcc_2_2_11_9_8_6) OR FIREABLE(TrainAcc_2_1_12_10_9_6) OR FIREABLE(TrainAcc_2_2_12_10_9_6) OR FIREABLE(TrainAcc_2_1_13_11_10_6) OR FIREABLE(TrainAcc_2_2_13_11_10_6) OR FIREABLE(TrainAcc_2_1_14_12_11_6) OR FIREABLE(TrainAcc_2_2_14_12_11_6) OR FIREABLE(TrainAcc_2_1_15_13_12_6) OR FIREABLE(TrainAcc_2_2_15_13_12_6) OR FIREABLE(TrainAcc_2_1_16_14_13_6) OR FIREABLE(TrainAcc_2_2_16_14_13_6) OR FIREABLE(TrainAcc_2_1_17_15_14_6) OR FIREABLE(TrainAcc_2_2_17_15_14_6) OR FIREABLE(TrainAcc_2_1_18_16_15_6) OR FIREABLE(TrainAcc_2_2_18_16_15_6) OR FIREABLE(TrainAcc_2_1_19_17_16_6) OR FIREABLE(TrainAcc_2_2_19_17_16_6) OR FIREABLE(TrainAcc_2_1_20_18_17_6) OR FIREABLE(TrainAcc_2_2_20_18_17_6) OR FIREABLE(TrainAcc_2_1_21_19_18_6) OR FIREABLE(TrainAcc_2_2_21_19_18_6) OR FIREABLE(TrainAcc_2_1_22_20_19_6) OR FIREABLE(TrainAcc_2_2_22_20_19_6) OR FIREABLE(TrainAcc_2_1_23_21_20_6) OR FIREABLE(TrainAcc_2_2_23_21_20_6) OR FIREABLE(TrainAcc_2_1_24_22_21_6) OR FIREABLE(TrainAcc_2_2_24_22_21_6) OR FIREABLE(TrainAcc_2_1_25_23_22_6) OR FIREABLE(TrainAcc_2_2_25_23_22_6) OR FIREABLE(TrainAcc_2_1_26_24_23_6) OR FIREABLE(TrainAcc_2_2_26_24_23_6) OR FIREABLE(TrainAcc_2_1_27_25_24_6) OR FIREABLE(TrainAcc_2_2_27_25_24_6) OR FIREABLE(TrainAcc_2_1_28_26_25_6) OR FIREABLE(TrainAcc_2_2_28_26_25_6) OR FIREABLE(TrainAcc_2_1_29_27_26_6) OR FIREABLE(TrainAcc_2_2_29_27_26_6) OR FIREABLE(TrainAcc_2_1_30_28_27_6) OR FIREABLE(TrainAcc_2_2_30_28_27_6) OR FIREABLE(TrainAcc_2_1_31_29_28_6) OR FIREABLE(TrainAcc_2_2_31_29_28_6) OR FIREABLE(TrainAcc_2_1_32_30_29_6) OR FIREABLE(TrainAcc_2_2_32_30_29_6) OR FIREABLE(TrainAcc_2_1_33_31_30_6) OR FIREABLE(TrainAcc_2_2_33_31_30_6) OR FIREABLE(TrainAcc_2_1_34_32_31_6) OR FIREABLE(TrainAcc_2_2_34_32_31_6) OR FIREABLE(TrainAcc_2_1_35_33_32_6) OR FIREABLE(TrainAcc_2_2_35_33_32_6) OR FIREABLE(TrainAcc_2_1_36_34_33_6) OR FIREABLE(TrainAcc_2_2_36_34_33_6) OR FIREABLE(TrainAcc_2_1_37_35_34_6) OR FIREABLE(TrainAcc_2_2_37_35_34_6) OR FIREABLE(TrainAcc_2_1_38_36_35_6) OR FIREABLE(TrainAcc_2_2_38_36_35_6) OR FIREABLE(TrainAcc_2_1_39_37_36_6) OR FIREABLE(TrainAcc_2_2_39_37_36_6) OR FIREABLE(TrainAcc_3_1_15_12_11_10) OR FIREABLE(TrainAcc_3_2_15_12_11_10) OR FIREABLE(TrainAcc_3_1_16_13_12_10) OR FIREABLE(TrainAcc_3_2_16_13_12_10) OR FIREABLE(TrainAcc_3_1_17_14_13_10) OR FIREABLE(TrainAcc_3_2_17_14_13_10) OR FIREABLE(TrainAcc_3_1_18_15_14_10) OR FIREABLE(TrainAcc_3_2_18_15_14_10) OR FIREABLE(TrainAcc_3_1_19_16_15_10) OR FIREABLE(TrainAcc_3_2_19_16_15_10) OR FIREABLE(TrainAcc_3_1_20_17_16_10) OR FIREABLE(TrainAcc_3_2_20_17_16_10) OR FIREABLE(TrainAcc_3_1_21_18_17_10) OR FIREABLE(TrainAcc_3_2_21_18_17_10) OR FIREABLE(TrainAcc_3_1_22_19_18_10) OR FIREABLE(TrainAcc_3_2_22_19_18_10) OR FIREABLE(TrainAcc_3_1_23_20_19_10) OR FIREABLE(TrainAcc_3_2_23_20_19_10) OR FIREABLE(TrainAcc_3_1_24_21_20_10) OR FIREABLE(TrainAcc_3_2_24_21_20_10) OR FIREABLE(TrainAcc_3_1_25_22_21_10) OR FIREABLE(TrainAcc_3_2_25_22_21_10) OR FIREABLE(TrainAcc_3_1_26_23_22_10) OR FIREABLE(TrainAcc_3_2_26_23_22_10) OR FIREABLE(TrainAcc_3_1_27_24_23_10) OR FIREABLE(TrainAcc_3_2_27_24_23_10) OR FIREABLE(TrainAcc_3_1_28_25_24_10) OR FIREABLE(TrainAcc_3_2_28_25_24_10) OR FIREABLE(TrainAcc_3_1_29_26_25_10) OR FIREABLE(TrainAcc_3_2_29_26_25_10) OR FIREABLE(TrainAcc_3_1_30_27_26_10) OR FIREABLE(TrainAcc_3_2_30_27_26_10) OR FIREABLE(TrainAcc_3_1_31_28_27_10) OR FIREABLE(TrainAcc_3_2_31_28_27_10) OR FIREABLE(TrainAcc_3_1_32_29_28_10) OR FIREABLE(TrainAcc_3_2_32_29_28_10) OR FIREABLE(TrainAcc_3_1_33_30_29_10) OR FIREABLE(TrainAcc_3_2_33_30_29_10) OR FIREABLE(TrainAcc_3_1_34_31_30_10) OR FIREABLE(TrainAcc_3_2_34_31_30_10) OR FIREABLE(TrainAcc_3_1_35_32_31_10) OR FIREABLE(TrainAcc_3_2_35_32_31_10) OR FIREABLE(TrainAcc_3_1_36_33_32_10) OR FIREABLE(TrainAcc_3_2_36_33_32_10) OR FIREABLE(TrainAcc_3_1_37_34_33_10) OR FIREABLE(TrainAcc_3_2_37_34_33_10))))) : A ((FIREABLE(TrainDecc_2_1_3_4_2_1_6) OR FIREABLE(TrainDecc_2_2_3_4_2_1_6) OR FIREABLE(TrainDecc_2_1_3_5_3_2_6) OR FIREABLE(TrainDecc_2_2_3_5_3_2_6) OR FIREABLE(TrainDecc_3_1_6_7_4_3_10) OR FIREABLE(TrainDecc_3_2_6_7_4_3_10) OR FIREABLE(TrainDecc_3_1_6_8_5_4_10) OR FIREABLE(TrainDecc_3_2_6_8_5_4_10) OR FIREABLE(TrainDecc_3_1_6_9_6_5_10) OR FIREABLE(TrainDecc_3_2_6_9_6_5_10) OR FIREABLE(TrainDecc_4_1_10_11_7_6_15) OR FIREABLE(TrainDecc_4_2_10_11_7_6_15) OR FIREABLE(TrainDecc_4_1_10_12_8_7_15) OR FIREABLE(TrainDecc_4_2_10_12_8_7_15) OR FIREABLE(TrainDecc_4_1_10_13_9_8_15) OR FIREABLE(TrainDecc_4_2_10_13_9_8_15) OR FIREABLE(TrainDecc_4_1_10_14_10_9_15) OR FIREABLE(TrainDecc_4_2_10_14_10_9_15))) : A (G (F (G ((FIREABLE(TrainStable_1_1_1_2_1_0_3) OR FIREABLE(TrainStable_1_2_1_2_1_0_3) OR FIREABLE(TrainStable_1_1_1_3_2_1_3) OR FIREABLE(TrainStable_1_2_1_3_2_1_3) OR FIREABLE(TrainStable_1_1_1_4_3_2_3) OR FIREABLE(TrainStable_1_2_1_4_3_2_3) OR FIREABLE(TrainStable_1_1_1_5_4_3_3) OR FIREABLE(TrainStable_1_2_1_5_4_3_3) OR FIREABLE(TrainStable_1_1_1_6_5_4_3) OR FIREABLE(TrainStable_1_2_1_6_5_4_3) OR FIREABLE(TrainStable_1_1_1_7_6_5_3) OR FIREABLE(TrainStable_1_2_1_7_6_5_3) OR FIREABLE(TrainStable_1_1_1_8_7_6_3) OR FIREABLE(TrainStable_1_2_1_8_7_6_3) OR FIREABLE(TrainStable_1_1_1_9_8_7_3) OR FIREABLE(TrainStable_1_2_1_9_8_7_3) OR FIREABLE(TrainStable_1_1_1_10_9_8_3) OR FIREABLE(TrainStable_1_2_1_10_9_8_3) OR FIREABLE(TrainStable_1_1_1_11_10_9_3) OR FIREABLE(TrainStable_1_2_1_11_10_9_3) OR FIREABLE(TrainStable_1_1_1_12_11_10_3) OR FIREABLE(TrainStable_1_2_1_12_11_10_3) OR FIREABLE(TrainStable_1_1_1_13_12_11_3) OR FIREABLE(TrainStable_1_2_1_13_12_11_3) OR FIREABLE(TrainStable_1_1_1_14_13_12_3) OR FIREABLE(TrainStable_1_2_1_14_13_12_3) OR FIREABLE(TrainStable_1_1_1_15_14_13_3) OR FIREABLE(TrainStable_1_2_1_15_14_13_3) OR FIREABLE(TrainStable_1_1_1_16_15_14_3) OR FIREABLE(TrainStable_1_2_1_16_15_14_3) OR FIREABLE(TrainStable_1_1_1_17_16_15_3) OR FIREABLE(TrainStable_1_2_1_17_16_15_3) OR FIREABLE(TrainStable_1_1_1_18_17_16_3) OR FIREABLE(TrainStable_1_2_1_18_17_16_3) OR FIREABLE(TrainStable_1_1_1_19_18_17_3) OR FIREABLE(TrainStable_1_2_1_19_18_17_3) OR FIREABLE(TrainStable_1_1_1_20_19_18_3) OR FIREABLE(TrainStable_1_2_1_20_19_18_3) OR FIREABLE(TrainStable_1_1_1_21_20_19_3) OR FIREABLE(TrainStable_1_2_1_21_20_19_3) OR FIREABLE(TrainStable_1_1_1_22_21_20_3) OR FIREABLE(TrainStable_1_2_1_22_21_20_3) OR FIREABLE(TrainStable_1_1_1_23_22_21_3) OR FIREABLE(TrainStable_1_2_1_23_22_21_3) OR FIREABLE(TrainStable_1_1_1_24_23_22_3) OR FIREABLE(TrainStable_1_2_1_24_23_22_3) OR FIREABLE(TrainStable_1_1_1_25_24_23_3) OR FIREABLE(TrainStable_1_2_1_25_24_23_3) OR FIREABLE(TrainStable_1_1_1_26_25_24_3) OR FIREABLE(TrainStable_1_2_1_26_25_24_3) OR FIREABLE(TrainStable_1_1_1_27_26_25_3) OR FIREABLE(TrainStable_1_2_1_27_26_25_3) OR FIREABLE(TrainStable_1_1_1_28_27_26_3) OR FIREABLE(TrainStable_1_2_1_28_27_26_3) OR FIREABLE(TrainStable_1_1_1_29_28_27_3) OR FIREABLE(TrainStable_1_2_1_29_28_27_3) OR FIREABLE(TrainStable_1_1_1_30_29_28_3) OR FIREABLE(TrainStable_1_2_1_30_29_28_3) OR FIREABLE(TrainStable_1_1_1_31_30_29_3) OR FIREABLE(TrainStable_1_2_1_31_30_29_3) OR FIREABLE(TrainStable_1_1_1_32_31_30_3) OR FIREABLE(TrainStable_1_2_1_32_31_30_3) OR FIREABLE(TrainStable_1_1_1_33_32_31_3) OR FIREABLE(TrainStable_1_2_1_33_32_31_3) OR FIREABLE(TrainStable_1_1_1_34_33_32_3) OR FIREABLE(TrainStable_1_2_1_34_33_32_3) OR FIREABLE(TrainStable_1_1_1_35_34_33_3) OR FIREABLE(TrainStable_1_2_1_35_34_33_3) OR FIREABLE(TrainStable_1_1_1_36_35_34_3) OR FIREABLE(TrainStable_1_2_1_36_35_34_3) OR FIREABLE(TrainStable_1_1_1_37_36_35_3) OR FIREABLE(TrainStable_1_2_1_37_36_35_3) OR FIREABLE(TrainStable_1_1_1_38_37_36_3) OR FIREABLE(TrainStable_1_2_1_38_37_36_3) OR FIREABLE(TrainStable_1_1_1_39_38_37_3) OR FIREABLE(TrainStable_1_2_1_39_38_37_3) OR FIREABLE(TrainStable_1_1_1_40_39_38_3) OR FIREABLE(TrainStable_1_2_1_40_39_38_3) OR FIREABLE(TrainStable_2_1_3_6_4_3_6) OR FIREABLE(TrainStable_2_2_3_6_4_3_6) OR FIREABLE(TrainStable_2_1_3_7_5_4_6) OR FIREABLE(TrainStable_2_2_3_7_5_4_6) OR FIREABLE(TrainStable_2_1_3_8_6_5_6) OR FIREABLE(TrainStable_2_2_3_8_6_5_6) OR FIREABLE(TrainStable_2_1_3_9_7_6_6) OR FIREABLE(TrainStable_2_2_3_9_7_6_6) OR FIREABLE(TrainStable_3_1_6_10_7_6_10) OR FIREABLE(TrainStable_3_2_6_10_7_6_10) OR FIREABLE(TrainStable_3_1_6_11_8_7_10) OR FIREABLE(TrainStable_3_2_6_11_8_7_10) OR FIREABLE(TrainStable_3_1_6_12_9_8_10) OR FIREABLE(TrainStable_3_2_6_12_9_8_10) OR FIREABLE(TrainStable_3_1_6_13_10_9_10) OR FIREABLE(TrainStable_3_2_6_13_10_9_10) OR FIREABLE(TrainStable_3_1_6_14_11_10_10) OR FIREABLE(TrainStable_3_2_6_14_11_10_10) OR FIREABLE(TrainStable_4_1_10_15_11_10_15) OR FIREABLE(TrainStable_4_2_10_15_11_10_15) OR FIREABLE(TrainStable_4_1_10_16_12_11_15) OR FIREABLE(TrainStable_4_2_10_16_12_11_15) OR FIREABLE(TrainStable_4_1_10_17_13_12_15) OR FIREABLE(TrainStable_4_2_10_17_13_12_15) OR FIREABLE(TrainStable_4_1_10_18_14_13_15) OR FIREABLE(TrainStable_4_2_10_18_14_13_15) OR FIREABLE(TrainStable_4_1_10_19_15_14_15) OR FIREABLE(TrainStable_4_2_10_19_15_14_15) OR FIREABLE(TrainStable_4_1_10_20_16_15_15) OR FIREABLE(TrainStable_4_2_10_20_16_15_15) OR FIREABLE(TrainStable_4_1_10_21_17_16_15) OR FIREABLE(TrainStable_4_2_10_21_17_16_15) OR FIREABLE(TrainStable_4_1_10_22_18_17_15) OR FIREABLE(TrainStable_4_2_10_22_18_17_15) OR FIREABLE(TrainStable_4_1_10_23_19_18_15) OR FIREABLE(TrainStable_4_2_10_23_19_18_15) OR FIREABLE(TrainStable_4_1_10_24_20_19_15) OR FIREABLE(TrainStable_4_2_10_24_20_19_15) OR FIREABLE(TrainStable_4_1_10_25_21_20_15) OR FIREABLE(TrainStable_4_2_10_25_21_20_15) OR FIREABLE(TrainStable_4_1_10_26_22_21_15) OR FIREABLE(TrainStable_4_2_10_26_22_21_15) OR FIREABLE(TrainStable_4_1_10_27_23_22_15) OR FIREABLE(TrainStable_4_2_10_27_23_22_15) OR FIREABLE(TrainStable_4_1_10_28_24_23_15) OR FIREABLE(TrainStable_4_2_10_28_24_23_15) OR FIREABLE(TrainStable_4_1_10_29_25_24_15) OR FIREABLE(TrainStable_4_2_10_29_25_24_15) OR FIREABLE(TrainStable_4_1_10_30_26_25_15) OR FIREABLE(TrainStable_4_2_10_30_26_25_15) OR FIREABLE(TrainStable_4_1_10_31_27_26_15) OR FIREABLE(TrainStable_4_2_10_31_27_26_15) OR FIREABLE(TrainStable_4_1_10_32_28_27_15) OR FIREABLE(TrainStable_4_2_10_32_28_27_15) OR FIREABLE(TrainStable_4_1_10_33_29_28_15) OR FIREABLE(TrainStable_4_2_10_33_29_28_15) OR FIREABLE(TrainStable_4_1_10_34_30_29_15) OR FIREABLE(TrainStable_4_2_10_34_30_29_15)))))) : A ((X (F (G ((FIREABLE(AtStation_1_5) OR FIREABLE(AtStation_2_5) OR FIREABLE(AtStation_1_6) OR FIREABLE(AtStation_2_6) OR FIREABLE(AtStation_1_7) OR FIREABLE(AtStation_2_7) OR FIREABLE(AtStation_1_8) OR FIREABLE(AtStation_2_8) OR FIREABLE(AtStation_1_9) OR FIREABLE(AtStation_2_9) OR FIREABLE(AtStation_1_10) OR FIREABLE(AtStation_2_10) OR FIREABLE(AtStation_1_11) OR FIREABLE(AtStation_2_11) OR FIREABLE(AtStation_1_12) OR FIREABLE(AtStation_2_12) OR FIREABLE(AtStation_1_13) OR FIREABLE(AtStation_2_13) OR FIREABLE(AtStation_1_14) OR FIREABLE(AtStation_2_14) OR FIREABLE(AtStation_1_15) OR FIREABLE(AtStation_2_15) OR FIREABLE(AtStation_1_16) OR FIREABLE(AtStation_2_16) OR FIREABLE(AtStation_1_17) OR FIREABLE(AtStation_2_17) OR FIREABLE(AtStation_1_18) OR FIREABLE(AtStation_2_18) OR FIREABLE(AtStation_1_19) OR FIREABLE(AtStation_2_19) OR FIREABLE(AtStation_1_20) OR FIREABLE(AtStation_2_20) OR FIREABLE(AtStation_1_21) OR FIREABLE(AtStation_2_21) OR FIREABLE(AtStation_1_22) OR FIREABLE(AtStation_2_22) OR FIREABLE(AtStation_1_23) OR FIREABLE(AtStation_2_23) OR FIREABLE(AtStation_1_24) OR FIREABLE(AtStation_2_24) OR FIREABLE(AtStation_1_25) OR FIREABLE(AtStation_2_25) OR FIREABLE(AtStation_1_26) OR FIREABLE(AtStation_2_26) OR FIREABLE(AtStation_1_27) OR FIREABLE(AtStation_2_27) OR FIREABLE(AtStation_1_28) OR FIREABLE(AtStation_2_28) OR FIREABLE(AtStation_1_29) OR FIREABLE(AtStation_2_29) OR FIREABLE(AtStation_1_30) OR FIR
EABLE(AtStation_2_30) OR FIREABLE(AtStation_1_31) OR FIREABLE(AtStation_2_31) OR FIREABLE(AtStation_1_32) OR FIREABLE(AtStation_2_32) OR FIREABLE(AtStation_1_33) OR FIREABLE(AtStation_2_33) OR FIREABLE(AtStation_1_34) OR FIREABLE(AtStation_2_34) OR FIREABLE(AtStation_1_35) OR FIREABLE(AtStation_2_35) OR FIREABLE(AtStation_1_36) OR FIREABLE(AtStation_2_36) OR FIREABLE(AtStation_1_37) OR FIREABLE(AtStation_2_37) OR FIREABLE(AtStation_1_38) OR FIREABLE(AtStation_2_38) OR FIREABLE(AtStation_1_39) OR FIREABLE(AtStation_2_39) OR FIREABLE(AtStation_1_40) OR FIREABLE(AtStation_2_40))))) U X (G ((FIREABLE(TrainDecc_2_1_3_4_2_1_6) OR FIREABLE(TrainDecc_2_2_3_4_2_1_6) OR FIREABLE(TrainDecc_2_1_3_5_3_2_6) OR FIREABLE(TrainDecc_2_2_3_5_3_2_6) OR FIREABLE(TrainDecc_3_1_6_7_4_3_10) OR FIREABLE(TrainDecc_3_2_6_7_4_3_10) OR FIREABLE(TrainDecc_3_1_6_8_5_4_10) OR FIREABLE(TrainDecc_3_2_6_8_5_4_10) OR FIREABLE(TrainDecc_3_1_6_9_6_5_10) OR FIREABLE(TrainDecc_3_2_6_9_6_5_10) OR FIREABLE(TrainDecc_4_1_10_11_7_6_15) OR FIREABLE(TrainDecc_4_2_10_11_7_6_15) OR FIREABLE(TrainDecc_4_1_10_12_8_7_15) OR FIREABLE(TrainDecc_4_2_10_12_8_7_15) OR FIREABLE(TrainDecc_4_1_10_13_9_8_15) OR FIREABLE(TrainDecc_4_2_10_13_9_8_15) OR FIREABLE(TrainDecc_4_1_10_14_10_9_15) OR FIREABLE(TrainDecc_4_2_10_14_10_9_15)))))) : A (G (X (G ((FIREABLE(TrainStable_1_1_1_2_1_0_3) OR FIREABLE(TrainStable_1_2_1_2_1_0_3) OR FIREABLE(TrainStable_1_1_1_3_2_1_3) OR FIREABLE(TrainStable_1_2_1_3_2_1_3) OR FIREABLE(TrainStable_1_1_1_4_3_2_3) OR FIREABLE(TrainStable_1_2_1_4_3_2_3) OR FIREABLE(TrainStable_1_1_1_5_4_3_3) OR FIREABLE(TrainStable_1_2_1_5_4_3_3) OR FIREABLE(TrainStable_1_1_1_6_5_4_3) OR FIREABLE(TrainStable_1_2_1_6_5_4_3) OR FIREABLE(TrainStable_1_1_1_7_6_5_3) OR FIREABLE(TrainStable_1_2_1_7_6_5_3) OR FIREABLE(TrainStable_1_1_1_8_7_6_3) OR FIREABLE(TrainStable_1_2_1_8_7_6_3) OR FIREABLE(TrainStable_1_1_1_9_8_7_3) OR FIREABLE(TrainStable_1_2_1_9_8_7_3) OR FIREABLE(TrainStable_1_1_1_10_9_8_3) OR FIREABLE(TrainStable_1_2_1_10_9_8_3) OR FIREABLE(TrainStable_1_1_1_11_10_9_3) OR FIREABLE(TrainStable_1_2_1_11_10_9_3) OR FIREABLE(TrainStable_1_1_1_12_11_10_3) OR FIREABLE(TrainStable_1_2_1_12_11_10_3) OR FIREABLE(TrainStable_1_1_1_13_12_11_3) OR FIREABLE(TrainStable_1_2_1_13_12_11_3) OR FIREABLE(TrainStable_1_1_1_14_13_12_3) OR FIREABLE(TrainStable_1_2_1_14_13_12_3) OR FIREABLE(TrainStable_1_1_1_15_14_13_3) OR FIREABLE(TrainStable_1_2_1_15_14_13_3) OR FIREABLE(TrainStable_1_1_1_16_15_14_3) OR FIREABLE(TrainStable_1_2_1_16_15_14_3) OR FIREABLE(TrainStable_1_1_1_17_16_15_3) OR FIREABLE(TrainStable_1_2_1_17_16_15_3) OR FIREABLE(TrainStable_1_1_1_18_17_16_3) OR FIREABLE(TrainStable_1_2_1_18_17_16_3) OR FIREABLE(TrainStable_1_1_1_19_18_17_3) OR FIREABLE(TrainStable_1_2_1_19_18_17_3) OR FIREABLE(TrainStable_1_1_1_20_19_18_3) OR FIREABLE(TrainStable_1_2_1_20_19_18_3) OR FIREABLE(TrainStable_1_1_1_21_20_19_3) OR FIREABLE(TrainStable_1_2_1_21_20_19_3) OR FIREABLE(TrainStable_1_1_1_22_21_20_3) OR FIREABLE(TrainStable_1_2_1_22_21_20_3) OR FIREABLE(TrainStable_1_1_1_23_22_21_3) OR FIREABLE(TrainStable_1_2_1_23_22_21_3) OR FIREABLE(TrainStable_1_1_1_24_23_22_3) OR FIREABLE(TrainStable_1_2_1_24_23_22_3) OR FIREABLE(TrainStable_1_1_1_25_24_23_3) OR FIREABLE(TrainStable_1_2_1_25_24_23_3) OR FIREABLE(TrainStable_1_1_1_26_25_24_3) OR FIREABLE(TrainStable_1_2_1_26_25_24_3) OR FIREABLE(TrainStable_1_1_1_27_26_25_3) OR FIREABLE(TrainStable_1_2_1_27_26_25_3) OR FIREABLE(TrainStable_1_1_1_28_27_26_3) OR FIREABLE(TrainStable_1_2_1_28_27_26_3) OR FIREABLE(TrainStable_1_1_1_29_28_27_3) OR FIREABLE(TrainStable_1_2_1_29_28_27_3) OR FIREABLE(TrainStable_1_1_1_30_29_28_3) OR FIREABLE(TrainStable_1_2_1_30_29_28_3) OR FIREABLE(TrainStable_1_1_1_31_30_29_3) OR FIREABLE(TrainStable_1_2_1_31_30_29_3) OR FIREABLE(TrainStable_1_1_1_32_31_30_3) OR FIREABLE(TrainStable_1_2_1_32_31_30_3) OR FIREABLE(TrainStable_1_1_1_33_32_31_3) OR FIREABLE(TrainStable_1_2_1_33_32_31_3) OR FIREABLE(TrainStable_1_1_1_34_33_32_3) OR FIREABLE(TrainStable_1_2_1_34_33_32_3) OR FIREABLE(TrainStable_1_1_1_35_34_33_3) OR FIREABLE(TrainStable_1_2_1_35_34_33_3) OR FIREABLE(TrainStable_1_1_1_36_35_34_3) OR FIREABLE(TrainStable_1_2_1_36_35_34_3) OR FIREABLE(TrainStable_1_1_1_37_36_35_3) OR FIREABLE(TrainStable_1_2_1_37_36_35_3) OR FIREABLE(TrainStable_1_1_1_38_37_36_3) OR FIREABLE(TrainStable_1_2_1_38_37_36_3) OR FIREABLE(TrainStable_1_1_1_39_38_37_3) OR FIREABLE(TrainStable_1_2_1_39_38_37_3) OR FIREABLE(TrainStable_1_1_1_40_39_38_3) OR FIREABLE(TrainStable_1_2_1_40_39_38_3) OR FIREABLE(TrainStable_2_1_3_6_4_3_6) OR FIREABLE(TrainStable_2_2_3_6_4_3_6) OR FIREABLE(TrainStable_2_1_3_7_5_4_6) OR FIREABLE(TrainStable_2_2_3_7_5_4_6) OR FIREABLE(TrainStable_2_1_3_8_6_5_6) OR FIREABLE(TrainStable_2_2_3_8_6_5_6) OR FIREABLE(TrainStable_2_1_3_9_7_6_6) OR FIREABLE(TrainStable_2_2_3_9_7_6_6) OR FIREABLE(TrainStable_3_1_6_10_7_6_10) OR FIREABLE(TrainStable_3_2_6_10_7_6_10) OR FIREABLE(TrainStable_3_1_6_11_8_7_10) OR FIREABLE(TrainStable_3_2_6_11_8_7_10) OR FIREABLE(TrainStable_3_1_6_12_9_8_10) OR FIREABLE(TrainStable_3_2_6_12_9_8_10) OR FIREABLE(TrainStable_3_1_6_13_10_9_10) OR FIREABLE(TrainStable_3_2_6_13_10_9_10) OR FIREABLE(TrainStable_3_1_6_14_11_10_10) OR FIREABLE(TrainStable_3_2_6_14_11_10_10) OR FIREABLE(TrainStable_4_1_10_15_11_10_15) OR FIREABLE(TrainStable_4_2_10_15_11_10_15) OR FIREABLE(TrainStable_4_1_10_16_12_11_15) OR FIREABLE(TrainStable_4_2_10_16_12_11_15) OR FIREABLE(TrainStable_4_1_10_17_13_12_15) OR FIREABLE(TrainStable_4_2_10_17_13_12_15) OR FIREABLE(TrainStable_4_1_10_18_14_13_15) OR FIREABLE(TrainStable_4_2_10_18_14_13_15) OR FIREABLE(TrainStable_4_1_10_19_15_14_15) OR FIREABLE(TrainStable_4_2_10_19_15_14_15) OR FIREABLE(TrainStable_4_1_10_20_16_15_15) OR FIREABLE(TrainStable_4_2_10_20_16_15_15) OR FIREABLE(TrainStable_4_1_10_21_17_16_15) OR FIREABLE(TrainStable_4_2_10_21_17_16_15) OR FIREABLE(TrainStable_4_1_10_22_18_17_15) OR FIREABLE(TrainStable_4_2_10_22_18_17_15) OR FIREABLE(TrainStable_4_1_10_23_19_18_15) OR FIREABLE(TrainStable_4_2_10_23_19_18_15) OR FIREABLE(TrainStable_4_1_10_24_20_19_15) OR FIREABLE(TrainStable_4_2_10_24_20_19_15) OR FIREABLE(TrainStable_4_1_10_25_21_20_15) OR FIREABLE(TrainStable_4_2_10_25_21_20_15) OR FIREABLE(TrainStable_4_1_10_26_22_21_15) OR FIREABLE(TrainStable_4_2_10_26_22_21_15) OR FIREABLE(TrainStable_4_1_10_27_23_22_15) OR FIREABLE(TrainStable_4_2_10_27_23_22_15) OR FIREABLE(TrainStable_4_1_10_28_24_23_15) OR FIREABLE(TrainStable_4_2_10_28_24_23_15) OR FIREABLE(TrainStable_4_1_10_29_25_24_15) OR FIREABLE(TrainStable_4_2_10_29_25_24_15) OR FIREABLE(TrainStable_4_1_10_30_26_25_15) OR FIREABLE(TrainStable_4_2_10_30_26_25_15) OR FIREABLE(TrainStable_4_1_10_31_27_26_15) OR FIREABLE(TrainStable_4_2_10_31_27_26_15) OR FIREABLE(TrainStable_4_1_10_32_28_27_15) OR FIREABLE(TrainStable_4_2_10_32_28_27_15) OR FIREABLE(TrainStable_4_1_10_33_29_28_15) OR FIREABLE(TrainStable_4_2_10_33_29_28_15) OR FIREABLE(TrainStable_4_1_10_34_30_29_15) OR FIREABLE(TrainStable_4_2_10_34_30_29_15)))))) : A (FIREABLE(TrainAcc_1_2_14_13_12_3)) : A (G ((F (G (FIREABLE(TrainStable_4_2_10_26_22_21_15))) U (FIREABLE(TrainAcc_1_2_32_31_30_3) U FIREABLE(TrainStable_1_1_1_15_14_13_3))))) : A (F (F (G (FIREABLE(TrainAcc_1_2_19_18_17_3))))) : A (FIREABLE(AtStation_2_37)) : A (FIREABLE(TrainAcc_2_2_18_16_15_6)) : A (G (G ((X (FIREABLE(AtStation_2_27)) U G (FIREABLE(TrainStable_2_1_3_7_5_4_6)))))) : A ((X (F (F (FIREABLE(TrainAcc_1_1_7_6_5_3)))) U G ((FIREABLE(TrainStable_1_1_1_5_4_3_3) U FIREABLE(AtStation_1_34))))) : A (FIREABLE(TrainStable_4_2_10_15_11_10_15))
lola: computing a collection of formulas
lola: RUNNING
lola: subprocess 0 will run for 221 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A ((X (X (G ((FIREABLE(TrainStop_1) OR FIREABLE(TrainStop_2))))) U G (G (X ((FIREABLE(TrainDecc_2_1_3_4_2_1_6) OR FIREABLE(TrainDecc_2_2_3_4_2_1_6) OR FIREABLE(TrainDecc_2_1_3_5_3_2_6) OR FIREABLE(TrainDecc_2_2_3_5_3_2_6) OR FIREABLE(TrainDecc_3_1_6_7_4_3_10) OR FIREABLE(TrainDecc_3_2_6_7_4_3_10) OR FIREABLE(TrainDecc_3_1_6_8_5_4_10) OR FIREABLE(TrainDecc_3_2_6_8_5_4_10) OR FIREABLE(Train... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking LTL
lola: transforming LTL-Formula into a B\xfcchi-Automaton
lola: processed formula: A ((X (X (G ((FIREABLE(TrainStop_1) OR FIREABLE(TrainStop_2))))) U G (G (X ((FIREABLE(TrainDecc_2_1_3_4_2_1_6) OR FIREABLE(TrainDecc_2_2_3_4_2_1_6) OR FIREABLE(TrainDecc_2_1_3_5_3_2_6) OR FIREABLE(TrainDecc_2_2_3_5_3_2_6) OR FIREABLE(TrainDecc_3_1_6_7_4_3_10) OR FIREABLE(TrainDecc_3_2_6_7_4_3_10) OR FIREABLE(TrainDecc_3_1_6_8_5_4_10) OR FIREABLE(TrainDecc_3_2_6_8_5_4_10) OR FIREABLE(TrainDecc_3_1_6_9_6_5_10) OR FIREABLE(TrainDecc_3_2_6_9_6_5_10) OR FIREABLE(TrainDecc_4_1_10_11_7_6_15) OR FIREABLE(TrainDecc_4_2_10_11_7_6_15) OR FIREABLE(TrainDecc_4_1_10_12_8_7_15) OR FIREABLE(TrainDecc_4_2_10_12_8_7_15) OR FIREABLE(TrainDecc_4_1_10_13_9_8_15) OR FIREABLE(TrainDecc_4_2_10_13_9_8_15) OR FIREABLE(TrainDecc_4_1_10_14_10_9_15) OR FIREABLE(TrainDecc_4_2_10_14_10_9_15)))))))
lola: processed formula: A ((X (X (G ((FIREABLE(TrainStop_1) OR FIREABLE(TrainStop_2))))) U G (G (X ((FIREABLE(TrainDecc_2_1_3_4_2_1_6) OR FIREABLE(TrainDecc_2_2_3_4_2_1_6) OR FIREABLE(TrainDecc_2_1_3_5_3_2_6) OR FIREABLE(TrainDecc_2_2_3_5_3_2_6) OR FIREABLE(TrainDecc_3_1_6_7_4_3_10) OR FIREABLE(TrainDecc_3_2_6_7_4_3_10) OR FIREABLE(TrainDecc_3_1_6_8_5_4_10) OR FIREABLE(TrainDecc_3_2_6_8_5_4_10) OR FIREABLE(Train... (shortened)
lola: processed formula length: 795
lola: 0 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: the resulting B\xfcchi automaton has 10 states
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 1052 bytes per marking, with 28 unused bits
lola: using a prefix tree store (--store=prefix)
lola: Formula contains X operator; stubborn sets not applicable
lola: SEARCH
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: LTL model checker
lola: The net does not satisfy the given formula (language of the product automaton is nonempty).
lola: 15 markings, 15 edges
lola: ========================================
lola: subprocess 1 will run for 236 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A (X (F ((FIREABLE(TrainStop_1) OR FIREABLE(TrainStop_2)))))
lola: ========================================
lola: SUBTASK
lola: checking LTL
lola: transforming LTL-Formula into a B\xfcchi-Automaton
lola: processed formula: A (X (F ((FIREABLE(TrainStop_1) OR FIREABLE(TrainStop_2)))))
lola: processed formula: A (X (F ((FIREABLE(TrainStop_1) OR FIREABLE(TrainStop_2)))))
lola: processed formula length: 61
lola: 0 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: the resulting B\xfcchi automaton has 2 states
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 1052 bytes per marking, with 30 unused bits
lola: using a prefix tree store (--store=prefix)
lola: Formula contains X operator; stubborn sets not applicable
lola: SEARCH
lola: RUNNING
lola: SUBRESULT
lola: result: yes
lola: produced by: LTL model checker
lola: The net satisfies the given formula (language of the product automaton is empty).
lola: 17423 markings, 52662 edges
lola: ========================================
lola: subprocess 2 will run for 252 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A (G (F (X (X (X ((FIREABLE(TrainDecc_2_1_3_4_2_1_6) OR FIREABLE(TrainDecc_2_2_3_4_2_1_6) OR FIREABLE(TrainDecc_2_1_3_5_3_2_6) OR FIREABLE(TrainDecc_2_2_3_5_3_2_6) OR FIREABLE(TrainDecc_3_1_6_7_4_3_10) OR FIREABLE(TrainDecc_3_2_6_7_4_3_10) OR FIREABLE(TrainDecc_3_1_6_8_5_4_10) OR FIREABLE(TrainDecc_3_2_6_8_5_4_10) OR FIREABLE(TrainDecc_3_1_6_9_6_5_10) OR FIREABLE(TrainDecc_3_2_6_9_6_5_10)... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking LTL
lola: transforming LTL-Formula into a B\xfcchi-Automaton
lola: processed formula: A (G (F (X (X (X ((FIREABLE(TrainDecc_2_1_3_4_2_1_6) OR FIREABLE(TrainDecc_2_2_3_4_2_1_6) OR FIREABLE(TrainDecc_2_1_3_5_3_2_6) OR FIREABLE(TrainDecc_2_2_3_5_3_2_6) OR FIREABLE(TrainDecc_3_1_6_7_4_3_10) OR FIREABLE(TrainDecc_3_2_6_7_4_3_10) OR FIREABLE(TrainDecc_3_1_6_8_5_4_10) OR FIREABLE(TrainDecc_3_2_6_8_5_4_10) OR FIREABLE(TrainDecc_3_1_6_9_6_5_10) OR FIREABLE(TrainDecc_3_2_6_9_6_5_10) OR FIREABLE(TrainDecc_4_1_10_11_7_6_15) OR FIREABLE(TrainDecc_4_2_10_11_7_6_15) OR FIREABLE(TrainDecc_4_1_10_12_8_7_15) OR FIREABLE(TrainDecc_4_2_10_12_8_7_15) OR FIREABLE(TrainDecc_4_1_10_13_9_8_15) OR FIREABLE(TrainDecc_4_2_10_13_9_8_15) OR FIREABLE(TrainDecc_4_1_10_14_10_9_15) OR FIREABLE(TrainDecc_4_2_10_14_10_9_15))))))))
lola: processed formula: A (G (F (X (X (X ((FIREABLE(TrainDecc_2_1_3_4_2_1_6) OR FIREABLE(TrainDecc_2_2_3_4_2_1_6) OR FIREABLE(TrainDecc_2_1_3_5_3_2_6) OR FIREABLE(TrainDecc_2_2_3_5_3_2_6) OR FIREABLE(TrainDecc_3_1_6_7_4_3_10) OR FIREABLE(TrainDecc_3_2_6_7_4_3_10) OR FIREABLE(TrainDecc_3_1_6_8_5_4_10) OR FIREABLE(TrainDecc_3_2_6_8_5_4_10) OR FIREABLE(TrainDecc_3_1_6_9_6_5_10) OR FIREABLE(TrainDecc_3_2_6_9_6_5_10)... (shortened)
lola: processed formula length: 737
lola: 0 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: the resulting B\xfcchi automaton has 4 states
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 1052 bytes per marking, with 29 unused bits
lola: using a prefix tree store (--store=prefix)
lola: Formula contains X operator; stubborn sets not applicable
lola: SEARCH
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: LTL model checker
lola: The net does not satisfy the given formula (language of the product automaton is nonempty).
lola: 36 markings, 36 edges
lola: ========================================
lola: subprocess 3 will run for 272 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A (G (G ((FIREABLE(TrainAcc_1_1_6_5_4_3) OR FIREABLE(TrainAcc_1_2_6_5_4_3) OR FIREABLE(TrainAcc_1_1_7_6_5_3) OR FIREABLE(TrainAcc_1_2_7_6_5_3) OR FIREABLE(TrainAcc_1_1_8_7_6_3) OR FIREABLE(TrainAcc_1_2_8_7_6_3) OR FIREABLE(TrainAcc_1_1_9_8_7_3) OR FIREABLE(TrainAcc_1_2_9_8_7_3) OR FIREABLE(TrainAcc_1_1_10_9_8_3) OR FIREABLE(TrainAcc_1_2_10_9_8_3) OR FIREABLE(TrainAcc_1_1_11_10_9_3) OR F... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking LTL
lola: transforming LTL-Formula into a B\xfcchi-Automaton
lola: processed formula: A (G (G ((FIREABLE(TrainAcc_1_1_6_5_4_3) OR FIREABLE(TrainAcc_1_2_6_5_4_3) OR FIREABLE(TrainAcc_1_1_7_6_5_3) OR FIREABLE(TrainAcc_1_2_7_6_5_3) OR FIREABLE(TrainAcc_1_1_8_7_6_3) OR FIREABLE(TrainAcc_1_2_8_7_6_3) OR FIREABLE(TrainAcc_1_1_9_8_7_3) OR FIREABLE(TrainAcc_1_2_9_8_7_3) OR FIREABLE(TrainAcc_1_1_10_9_8_3) OR FIREABLE(TrainAcc_1_2_10_9_8_3) OR FIREABLE(TrainAcc_1_1_11_10_9_3) OR FIREABLE(TrainAcc_1_2_11_10_9_3) OR FIREABLE(TrainAcc_1_1_12_11_10_3) OR FIREABLE(TrainAcc_1_2_12_11_10_3) OR FIREABLE(TrainAcc_1_1_13_12_11_3) OR FIREABLE(TrainAcc_1_2_13_12_11_3) OR FIREABLE(TrainAcc_1_1_14_13_12_3) OR FIREABLE(TrainAcc_1_2_14_13_12_3) OR FIREABLE(TrainAcc_1_1_15_14_13_3) OR FIREABLE(TrainAcc_1_2_15_14_13_3) OR FIREABLE(TrainAcc_1_1_16_15_14_3) OR FIREABLE(TrainAcc_1_2_16_15_14_3) OR FIREABLE(TrainAcc_1_1_17_16_15_3) OR FIREABLE(TrainAcc_1_2_17_16_15_3) OR FIREABLE(TrainAcc_1_1_18_17_16_3) OR FIREABLE(TrainAcc_1_2_18_17_16_3) OR FIREABLE(TrainAcc_1_1_19_18_17_3) OR FIREABLE(TrainAcc_1_2_19_18_17_3) OR FIREABLE(TrainAcc_1_1_20_19_18_3) OR FIREABLE(TrainAcc_1_2_20_19_18_3) OR FIREABLE(TrainAcc_1_1_21_20_19_3) OR FIREABLE(TrainAcc_1_2_21_20_19_3) OR FIREABLE(TrainAcc_1_1_22_21_20_3) OR FIREABLE(TrainAcc_1_2_22_21_20_3) OR FIREABLE(TrainAcc_1_1_23_22_21_3) OR FIREABLE(TrainAcc_1_2_23_22_21_3) OR FIREABLE(TrainAcc_1_1_24_23_22_3) OR FIREABLE(TrainAcc_1_2_24_23_22_3) OR FIREABLE(TrainAcc_1_1_25_24_23_3) OR FIREABLE(TrainAcc_1_2_25_24_23_3) OR FIREABLE(TrainAcc_1_1_26_25_24_3) OR FIREABLE(TrainAcc_1_2_26_25_24_3) OR FIREABLE(TrainAcc_1_1_27_26_25_3) OR FIREABLE(TrainAcc_1_2_27_26_25_3) OR FIREABLE(TrainAcc_1_1_28_27_26_3) OR FIREABLE(TrainAcc_1_2_28_27_26_3) OR FIREABLE(TrainAcc_1_1_29_28_27_3) OR FIREABLE(TrainAcc_1_2_29_28_27_3) OR FIREABLE(TrainAcc_1_1_30_29_28_3) OR FIREABLE(TrainAcc_1_2_30_29_28_3) OR FIREABLE(TrainAcc_1_1_31_30_29_3) OR FIREABLE(TrainAcc_1_2_31_30_29_3) OR FIREABLE(TrainAcc_1_1_32_31_30_3) OR FIREABLE(TrainAcc_1_2_32_31_30_3) OR FIREABLE(TrainAcc_1_1_33_32_31_3) OR FIREABLE(TrainAcc_1_2_33_32_31_3) OR FIREABLE(TrainAcc_1_1_34_33_32_3) OR FIREABLE(TrainAcc_1_2_34_33_32_3) OR FIREABLE(TrainAcc_1_1_35_34_33_3) OR FIREABLE(TrainAcc_1_2_35_34_33_3) OR FIREABLE(TrainAcc_1_1_36_35_34_3) OR FIREABLE(TrainAcc_1_2_36_35_34_3) OR FIREABLE(TrainAcc_1_1_37_36_35_3) OR FIREABLE(TrainAcc_1_2_37_36_35_3) OR FIREABLE(TrainAcc_1_1_38_37_36_3) OR FIREABLE(TrainAcc_1_2_38_37_36_3) OR FIREABLE(TrainAcc_1_1_39_38_37_3) OR FIREABLE(TrainAcc_1_2_39_38_37_3) OR FIREABLE(TrainAcc_1_1_40_39_38_3) OR FIREABLE(TrainAcc_1_2_40_39_38_3) OR FIREABLE(TrainAcc_2_1_10_8_7_6) OR FIREABLE(TrainAcc_2_2_10_8_7_6) OR FIREABLE(TrainAcc_2_1_11_9_8_6) OR FIREABLE(TrainAcc_2_2_11_9_8_6) OR FIREABLE(TrainAcc_2_1_12_10_9_6) OR FIREABLE(TrainAcc_2_2_12_10_9_6) OR FIREABLE(TrainAcc_2_1_13_11_10_6) OR FIREABLE(TrainAcc_2_2_13_11_10_6) OR FIREABLE(TrainAcc_2_1_14_12_11_6) OR FIREABLE(TrainAcc_2_2_14_12_11_6) OR FIREABLE(TrainAcc_2_1_15_13_12_6) OR FIREABLE(TrainAcc_2_2_15_13_12_6) OR FIREABLE(TrainAcc_2_1_16_14_13_6) OR FIREABLE(TrainAcc_2_2_16_14_13_6) OR FIREABLE(TrainAcc_2_1_17_15_14_6) OR FIREABLE(TrainAcc_2_2_17_15_14_6) OR FIREABLE(TrainAcc_2_1_18_16_15_6) OR FIREABLE(TrainAcc_2_2_18_16_15_6) OR FIREABLE(TrainAcc_2_1_19_17_16_6) OR FIREABLE(TrainAcc_2_2_19_17_16_6) OR FIREABLE(TrainAcc_2_1_20_18_17_6) OR FIREABLE(TrainAcc_2_2_20_18_17_6) OR FIREABLE(TrainAcc_2_1_21_19_18_6) OR FIREABLE(TrainAcc_2_2_21_19_18_6) OR FIREABLE(TrainAcc_2_1_22_20_19_6) OR FIREABLE(TrainAcc_2_2_22_20_19_6) OR FIREABLE(TrainAcc_2_1_23_21_20_6) OR FIREABLE(TrainAcc_2_2_23_21_20_6) OR FIREABLE(TrainAcc_2_1_24_22_21_6) OR FIREABLE(TrainAcc_2_2_24_22_21_6) OR FIREABLE(TrainAcc_2_1_25_23_22_6) OR FIREABLE(TrainAcc_2_2_25_23_22_6) OR FIREABLE(TrainAcc_2_1_26_24_23_6) OR FIREABLE(TrainAcc_2_2_26_24_23_6) OR FIREABLE(TrainAcc_2_1_27_25_24_6) OR FIREABLE(TrainAcc_2_2_27_25_24_6) OR FIREABLE(TrainAcc_2_1_28_26_25_6) OR FIREABLE(TrainAcc_2_2_28_26_25_6) OR FIREABLE(TrainAcc_2_1_29_27_26_6) OR FIREABLE(TrainAcc_2_2_29_27_26_6) OR FIREABLE(TrainAcc_2_1_30_28_27_6) OR FIREABLE(TrainAcc_2_2_30_28_27_6) OR FIREABLE(TrainAcc_2_1_31_29_28_6) OR FIREABLE(TrainAcc_2_2_31_29_28_6) OR FIREABLE(TrainAcc_2_1_32_30_29_6) OR FIREABLE(TrainAcc_2_2_32_30_29_6) OR FIREABLE(TrainAcc_2_1_33_31_30_6) OR FIREABLE(TrainAcc_2_2_33_31_30_6) OR FIREABLE(TrainAcc_2_1_34_32_31_6) OR FIREABLE(TrainAcc_2_2_34_32_31_6) OR FIREABLE(TrainAcc_2_1_35_33_32_6) OR FIREABLE(TrainAcc_2_2_35_33_32_6) OR FIREABLE(TrainAcc_2_1_36_34_33_6) OR FIREABLE(TrainAcc_2_2_36_34_33_6) OR FIREABLE(TrainAcc_2_1_37_35_34_6) OR FIREABLE(TrainAcc_2_2_37_35_34_6) OR FIREABLE(TrainAcc_2_1_38_36_35_6) OR FIREABLE(TrainAcc_2_2_38_36_35_6) OR FIREABLE(TrainAcc_2_1_39_37_36_6) OR FIREABLE(TrainAcc_2_2_39_37_36_6) OR FIREABLE(TrainAcc_3_1_15_12_11_10) OR FIREABLE(TrainAcc_3_2_15_12_11_10) OR FIREABLE(TrainAcc_3_1_16_13_12_10) OR FIREABLE(TrainAcc_3_2_16_13_12_10) OR FIREABLE(TrainAcc_3_1_17_14_13_10) OR FIREABLE(TrainAcc_3_2_17_14_13_10) OR FIREABLE(TrainAcc_3_1_18_15_14_10) OR FIREABLE(TrainAcc_3_2_18_15_14_10) OR FIREABLE(TrainAcc_3_1_19_16_15_10) OR FIREABLE(TrainAcc_3_2_19_16_15_10) OR FIREABLE(TrainAcc_3_1_20_17_16_10) OR FIREABLE(TrainAcc_3_2_20_17_16_10) OR FIREABLE(TrainAcc_3_1_21_18_17_10) OR FIREABLE(TrainAcc_3_2_21_18_17_10) OR FIREABLE(TrainAcc_3_1_22_19_18_10) OR FIREABLE(TrainAcc_3_2_22_19_18_10) OR FIREABLE(TrainAcc_3_1_23_20_19_10) OR FIREABLE(TrainAcc_3_2_23_20_19_10) OR FIREABLE(TrainAcc_3_1_24_21_20_10) OR FIREABLE(TrainAcc_3_2_24_21_20_10) OR FIREABLE(TrainAcc_3_1_25_22_21_10) OR FIREABLE(TrainAcc_3_2_25_22_21_10) OR FIREABLE(TrainAcc_3_1_26_23_22_10) OR FIREABLE(TrainAcc_3_2_26_23_22_10) OR FIREABLE(TrainAcc_3_1_27_24_23_10) OR FIREABLE(TrainAcc_3_2_27_24_23_10) OR FIREABLE(TrainAcc_3_1_28_25_24_10) OR FIREABLE(TrainAcc_3_2_28_25_24_10) OR FIREABLE(TrainAcc_3_1_29_26_25_10) OR FIREABLE(TrainAcc_3_2_29_26_25_10) OR FIREABLE(TrainAcc_3_1_30_27_26_10) OR FIREABLE(TrainAcc_3_2_30_27_26_10) OR FIREABLE(TrainAcc_3_1_31_28_27_10) OR FIREABLE(TrainAcc_3_2_31_28_27_10) OR FIREABLE(TrainAcc_3_1_32_29_28_10) OR FIREABLE(TrainAcc_3_2_32_29_28_10) OR FIREABLE(TrainAcc_3_1_33_30_29_10) OR FIREABLE(TrainAcc_3_2_33_30_29_10) OR FIREABLE(TrainAcc_3_1_34_31_30_10) OR FIREABLE(TrainAcc_3_2_34_31_30_10) OR FIREABLE(TrainAcc_3_1_35_32_31_10) OR FIREABLE(TrainAcc_3_2_35_32_31_10) OR FIREABLE(TrainAcc_3_1_36_33_32_10) OR FIREABLE(TrainAcc_3_2_36_33_32_10) OR FIREABLE(TrainAcc_3_1_37_34_33_10) OR FIREABLE(TrainAcc_3_2_37_34_33_10)))))
lola: processed formula: A (G (G ((FIREABLE(TrainAcc_1_1_6_5_4_3) OR FIREABLE(TrainAcc_1_2_6_5_4_3) OR FIREABLE(TrainAcc_1_1_7_6_5_3) OR FIREABLE(TrainAcc_1_2_7_6_5_3) OR FIREABLE(TrainAcc_1_1_8_7_6_3) OR FIREABLE(TrainAcc_1_2_8_7_6_3) OR FIREABLE(TrainAcc_1_1_9_8_7_3) OR FIREABLE(TrainAcc_1_2_9_8_7_3) OR FIREABLE(TrainAcc_1_1_10_9_8_3) OR FIREABLE(TrainAcc_1_2_10_9_8_3) OR FIREABLE(TrainAcc_1_1_11_10_9_3) OR F... (shortened)
lola: processed formula length: 6703
lola: 0 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: the resulting B\xfcchi automaton has 2 states
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 1052 bytes per marking, with 30 unused bits
lola: using a prefix tree store (--store=prefix)
lola: using ltl preserving stubborn set method (--stubborn)
lola: SEARCH
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: LTL model checker
lola: The net does not satisfy the given formula (language of the product automaton is nonempty).
lola: 15 markings, 15 edges
lola: ========================================
lola: subprocess 4 will run for 295 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A ((FIREABLE(TrainDecc_2_1_3_4_2_1_6) OR FIREABLE(TrainDecc_2_2_3_4_2_1_6) OR FIREABLE(TrainDecc_2_1_3_5_3_2_6) OR FIREABLE(TrainDecc_2_2_3_5_3_2_6) OR FIREABLE(TrainDecc_3_1_6_7_4_3_10) OR FIREABLE(TrainDecc_3_2_6_7_4_3_10) OR FIREABLE(TrainDecc_3_1_6_8_5_4_10) OR FIREABLE(TrainDecc_3_2_6_8_5_4_10) OR FIREABLE(TrainDecc_3_1_6_9_6_5_10) OR FIREABLE(TrainDecc_3_2_6_9_6_5_10) OR FIREABLE(T... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking initial satisfaction
lola: processed formula: (FIREABLE(TrainDecc_2_1_3_4_2_1_6) OR FIREABLE(TrainDecc_2_2_3_4_2_1_6) OR FIREABLE(TrainDecc_2_1_3_5_3_2_6) OR FIREABLE(TrainDecc_2_2_3_5_3_2_6) OR FIREABLE(TrainDecc_3_1_6_7_4_3_10) OR FIREABLE(TrainDecc_3_2_6_7_4_3_10) OR FIREABLE(TrainDecc_3_1_6_8_5_4_10) OR FIREABLE(TrainDecc_3_2_6_8_5_4_10) OR FIREABLE(TrainDecc_3_1_6_9_6_5_10) OR FIREABLE(TrainDecc_3_2_6_9_6_5_10) OR FIREABLE(Trai... (shortened)
lola: processed formula length: 713
lola: 1 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: processed formula with 0 atomic propositions
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: preprocessing
lola: The net violates the given property already in its initial state.
lola: 0 markings, 0 edges
lola: ========================================
lola: subprocess 5 will run for 321 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A (G (F (G ((FIREABLE(TrainStable_1_1_1_2_1_0_3) OR FIREABLE(TrainStable_1_2_1_2_1_0_3) OR FIREABLE(TrainStable_1_1_1_3_2_1_3) OR FIREABLE(TrainStable_1_2_1_3_2_1_3) OR FIREABLE(TrainStable_1_1_1_4_3_2_3) OR FIREABLE(TrainStable_1_2_1_4_3_2_3) OR FIREABLE(TrainStable_1_1_1_5_4_3_3) OR FIREABLE(TrainStable_1_2_1_5_4_3_3) OR FIREABLE(TrainStable_1_1_1_6_5_4_3) OR FIREABLE(TrainStable_1_2_1_... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking LTL
lola: transforming LTL-Formula into a B\xfcchi-Automaton
lola: processed formula: A (F (G ((FIREABLE(TrainStable_1_1_1_2_1_0_3) OR FIREABLE(TrainStable_1_2_1_2_1_0_3) OR FIREABLE(TrainStable_1_1_1_3_2_1_3) OR FIREABLE(TrainStable_1_2_1_3_2_1_3) OR FIREABLE(TrainStable_1_1_1_4_3_2_3) OR FIREABLE(TrainStable_1_2_1_4_3_2_3) OR FIREABLE(TrainStable_1_1_1_5_4_3_3) OR FIREABLE(TrainStable_1_2_1_5_4_3_3) OR FIREABLE(TrainStable_1_1_1_6_5_4_3) OR FIREABLE(TrainStable_1_2_1_6_5_4_3) OR FIREABLE(TrainStable_1_1_1_7_6_5_3) OR FIREABLE(TrainStable_1_2_1_7_6_5_3) OR FIREABLE(TrainStable_1_1_1_8_7_6_3) OR FIREABLE(TrainStable_1_2_1_8_7_6_3) OR FIREABLE(TrainStable_1_1_1_9_8_7_3) OR FIREABLE(TrainStable_1_2_1_9_8_7_3) OR FIREABLE(TrainStable_1_1_1_10_9_8_3) OR FIREABLE(TrainStable_1_2_1_10_9_8_3) OR FIREABLE(TrainStable_1_1_1_11_10_9_3) OR FIREABLE(TrainStable_1_2_1_11_10_9_3) OR FIREABLE(TrainStable_1_1_1_12_11_10_3) OR FIREABLE(TrainStable_1_2_1_12_11_10_3) OR FIREABLE(TrainStable_1_1_1_13_12_11_3) OR FIREABLE(TrainStable_1_2_1_13_12_11_3) OR FIREABLE(TrainStable_1_1_1_14_13_12_3) OR FIREABLE(TrainStable_1_2_1_14_13_12_3) OR FIREABLE(TrainStable_1_1_1_15_14_13_3) OR FIREABLE(TrainStable_1_2_1_15_14_13_3) OR FIREABLE(TrainStable_1_1_1_16_15_14_3) OR FIREABLE(TrainStable_1_2_1_16_15_14_3) OR FIREABLE(TrainStable_1_1_1_17_16_15_3) OR FIREABLE(TrainStable_1_2_1_17_16_15_3) OR FIREABLE(TrainStable_1_1_1_18_17_16_3) OR FIREABLE(TrainStable_1_2_1_18_17_16_3) OR FIREABLE(TrainStable_1_1_1_19_18_17_3) OR FIREABLE(TrainStable_1_2_1_19_18_17_3) OR FIREABLE(TrainStable_1_1_1_20_19_18_3) OR FIREABLE(TrainStable_1_2_1_20_19_18_3) OR FIREABLE(TrainStable_1_1_1_21_20_19_3) OR FIREABLE(TrainStable_1_2_1_21_20_19_3) OR FIREABLE(TrainStable_1_1_1_22_21_20_3) OR FIREABLE(TrainStable_1_2_1_22_21_20_3) OR FIREABLE(TrainStable_1_1_1_23_22_21_3) OR FIREABLE(TrainStable_1_2_1_23_22_21_3) OR FIREABLE(TrainStable_1_1_1_24_23_22_3) OR FIREABLE(TrainStable_1_2_1_24_23_22_3) OR FIREABLE(TrainStable_1_1_1_25_24_23_3) OR FIREABLE(TrainStable_1_2_1_25_24_23_3) OR FIREABLE(TrainStable_1_1_1_26_25_24_3) OR FIREABLE(TrainStable_1_2_1_26_25_24_3) OR FIREABLE(TrainStable_1_1_1_27_26_25_3) OR FIREABLE(TrainStable_1_2_1_27_26_25_3) OR FIREABLE(TrainStable_1_1_1_28_27_26_3) OR FIREABLE(TrainStable_1_2_1_28_27_26_3) OR FIREABLE(TrainStable_1_1_1_29_28_27_3) OR FIREABLE(TrainStable_1_2_1_29_28_27_3) OR FIREABLE(TrainStable_1_1_1_30_29_28_3) OR FIREABLE(TrainStable_1_2_1_30_29_28_3) OR FIREABLE(TrainStable_1_1_1_31_30_29_3) OR FIREABLE(TrainStable_1_2_1_31_30_29_3) OR FIREABLE(TrainStable_1_1_1_32_31_30_3) OR FIREABLE(TrainStable_1_2_1_32_31_30_3) OR FIREABLE(TrainStable_1_1_1_33_32_31_3) OR FIREABLE(TrainStable_1_2_1_33_32_31_3) OR FIREABLE(TrainStable_1_1_1_34_33_32_3) OR FIREABLE(TrainStable_1_2_1_34_33_32_3) OR FIREABLE(TrainStable_1_1_1_35_34_33_3) OR FIREABLE(TrainStable_1_2_1_35_34_33_3) OR FIREABLE(TrainStable_1_1_1_36_35_34_3) OR FIREABLE(TrainStable_1_2_1_36_35_34_3) OR FIREABLE(TrainStable_1_1_1_37_36_35_3) OR FIREABLE(TrainStable_1_2_1_37_36_35_3) OR FIREABLE(TrainStable_1_1_1_38_37_36_3) OR FIREABLE(TrainStable_1_2_1_38_37_36_3) OR FIREABLE(TrainStable_1_1_1_39_38_37_3) OR FIREABLE(TrainStable_1_2_1_39_38_37_3) OR FIREABLE(TrainStable_1_1_1_40_39_38_3) OR FIREABLE(TrainStable_1_2_1_40_39_38_3) OR FIREABLE(TrainStable_2_1_3_6_4_3_6) OR FIREABLE(TrainStable_2_2_3_6_4_3_6) OR FIREABLE(TrainStable_2_1_3_7_5_4_6) OR FIREABLE(TrainStable_2_2_3_7_5_4_6) OR FIREABLE(TrainStable_2_1_3_8_6_5_6) OR FIREABLE(TrainStable_2_2_3_8_6_5_6) OR FIREABLE(TrainStable_2_1_3_9_7_6_6) OR FIREABLE(TrainStable_2_2_3_9_7_6_6) OR FIREABLE(TrainStable_3_1_6_10_7_6_10) OR FIREABLE(TrainStable_3_2_6_10_7_6_10) OR FIREABLE(TrainStable_3_1_6_11_8_7_10) OR FIREABLE(TrainStable_3_2_6_11_8_7_10) OR FIREABLE(TrainStable_3_1_6_12_9_8_10) OR FIREABLE(TrainStable_3_2_6_12_9_8_10) OR FIREABLE(TrainStable_3_1_6_13_10_9_10) OR FIREABLE(TrainStable_3_2_6_13_10_9_10) OR FIREABLE(TrainStable_3_1_6_14_11_10_10) OR FIREABLE(TrainStable_3_2_6_14_11_10_10) OR FIREABLE(TrainStable_4_1_10_15_11_10_15) OR FIREABLE(TrainStable_4_2_10_15_11_10_15) OR FIREABLE(TrainStable_4_1_10_16_12_11_15) OR FIREABLE(TrainStable_4_2_10_16_12_11_15) OR FIREABLE(TrainStable_4_1_10_17_13_12_15) OR FIREABLE(TrainStable_4_2_10_17_13_12_15) OR FIREABLE(TrainStable_4_1_10_18_14_13_15) OR FIREABLE(TrainStable_4_2_10_18_14_13_15) OR FIREABLE(TrainStable_4_1_10_19_15_14_15) OR FIREABLE(TrainStable_4_2_10_19_15_14_15) OR FIREABLE(TrainStable_4_1_10_20_16_15_15) OR FIREABLE(TrainStable_4_2_10_20_16_15_15) OR FIREABLE(TrainStable_4_1_10_21_17_16_15) OR FIREABLE(TrainStable_4_2_10_21_17_16_15) OR FIREABLE(TrainStable_4_1_10_22_18_17_15) OR FIREABLE(TrainStable_4_2_10_22_18_17_15) OR FIREABLE(TrainStable_4_1_10_23_19_18_15) OR FIREABLE(TrainStable_4_2_10_23_19_18_15) OR FIREABLE(TrainStable_4_1_10_24_20_19_15) OR FIREABLE(TrainStable_4_2_10_24_20_19_15) OR FIREABLE(TrainStable_4_1_10_25_21_20_15) OR FIREABLE(TrainStable_4_2_10_25_21_20_15) OR FIREABLE(TrainStable_4_1_10_26_22_21_15) OR FIREABLE(TrainStable_4_2_10_26_22_21_15) OR FIREABLE(TrainStable_4_1_10_27_23_22_15) OR FIREABLE(TrainStable_4_2_10_27_23_22_15) OR FIREABLE(TrainStable_4_1_10_28_24_23_15) OR FIREABLE(TrainStable_4_2_10_28_24_23_15) OR FIREABLE(TrainStable_4_1_10_29_25_24_15) OR FIREABLE(TrainStable_4_2_10_29_25_24_15) OR FIREABLE(TrainStable_4_1_10_30_26_25_15) OR FIREABLE(TrainStable_4_2_10_30_26_25_15) OR FIREABLE(TrainStable_4_1_10_31_27_26_15) OR FIREABLE(TrainStable_4_2_10_31_27_26_15) OR FIREABLE(TrainStable_4_1_10_32_28_27_15) OR FIREABLE(TrainStable_4_2_10_32_28_27_15) OR FIREABLE(TrainStable_4_1_10_33_29_28_15) OR FIREABLE(TrainStable_4_2_10_33_29_28_15) OR FIREABLE(TrainStable_4_1_10_34_30_29_15) OR FIREABLE(TrainStable_4_2_10_34_30_29_15)))))
lola: processed formula: A (F (G ((FIREABLE(TrainStable_1_1_1_2_1_0_3) OR FIREABLE(TrainStable_1_2_1_2_1_0_3) OR FIREABLE(TrainStable_1_1_1_3_2_1_3) OR FIREABLE(TrainStable_1_2_1_3_2_1_3) OR FIREABLE(TrainStable_1_1_1_4_3_2_3) OR FIREABLE(TrainStable_1_2_1_4_3_2_3) OR FIREABLE(TrainStable_1_1_1_5_4_3_3) OR FIREABLE(TrainStable_1_2_1_5_4_3_3) OR FIREABLE(TrainStable_1_1_1_6_5_4_3) OR FIREABLE(TrainStable_1_2_1_6_5... (shortened)
lola: processed formula length: 5855
lola: 1 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: the resulting B\xfcchi automaton has 2 states
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 1052 bytes per marking, with 30 unused bits
lola: using a prefix tree store (--store=prefix)
lola: using ltl preserving stubborn set method (--stubborn)
lola: SEARCH
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: LTL model checker
lola: The net does not satisfy the given formula (language of the product automaton is nonempty).
lola: 35 markings, 41 edges
lola: ========================================
lola: subprocess 6 will run for 354 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A ((X (F (G ((FIREABLE(AtStation_1_5) OR FIREABLE(AtStation_2_5) OR FIREABLE(AtStation_1_6) OR FIREABLE(AtStation_2_6) OR FIREABLE(AtStation_1_7) OR FIREABLE(AtStation_2_7) OR FIREABLE(AtStation_1_8) OR FIREABLE(AtStation_2_8) OR FIREABLE(AtStation_1_9) OR FIREABLE(AtStation_2_9) OR FIREABLE(AtStation_1_10) OR FIREABLE(AtStation_2_10) OR FIREABLE(AtStation_1_11) OR FIREABLE(AtStation_... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking LTL
lola: transforming LTL-Formula into a B\xfcchi-Automaton
lola: processed formula: A (X ((F (G ((FIREABLE(AtStation_1_5) OR FIREABLE(AtStation_2_5) OR FIREABLE(AtStation_1_6) OR FIREABLE(AtStation_2_6) OR FIREABLE(AtStation_1_7) OR FIREABLE(AtStation_2_7) OR FIREABLE(AtStation_1_8) OR FIREABLE(AtStation_2_8) OR FIREABLE(AtStation_1_9) OR FIREABLE(AtStation_2_9) OR FIREABLE(AtStation_1_10) OR FIREABLE(AtStation_2_10) OR FIREABLE(AtStation_1_11) OR FIREABLE(AtStation_2_11) OR FIREABLE(AtStation_1_12) OR FIREABLE(AtStation_2_12) OR FIREABLE(AtStation_1_13) OR FIREABLE(AtStation_2_13) OR FIREABLE(AtStation_1_14) OR FIREABLE(AtStation_2_14) OR FIREABLE(AtStation_1_15) OR FIREABLE(AtStation_2_15) OR FIREABLE(AtStation_1_16) OR FIREABLE(AtStation_2_16) OR FIREABLE(AtStation_1_17) OR FIREABLE(AtStation_2_17) OR FIREABLE(AtStation_1_18) OR FIREABLE(AtStation_2_18) OR FIREABLE(AtStation_1_19) OR FIREABLE(AtStation_2_19) OR FIREABLE(AtStation_1_20) OR FIREABLE(AtStation_2_20) OR FIREABLE(AtStation_1_21) OR FIREABLE(AtStation_2_21) OR FIREABLE(AtStation_1_22) OR FIREABLE(AtStation_2_22) OR FIREABLE(AtStation_1_23) OR FIREABLE(AtStation_2_23) OR FIREABLE(AtStation_1_24) OR FIREABLE(AtStation_2_24) OR FIREABLE(AtStation_1_25) OR FIREABLE(AtStation_2_25) OR FIREABLE(AtStation_1_26) OR FIREABLE(AtStation_2_26) OR FIREABLE(AtStation_1_27) OR FIREABLE(AtStation_2_27) OR FIREABLE(AtStation_1_28) OR FIREABLE(AtStation_2_28) OR FIREABLE(AtStation_1_29) OR FIREABLE(AtStation_2_29) OR FIREABLE(AtStation_1_30) OR FIREABLE(AtStation_2_30) OR FIREABLE(AtStation_1_31) OR FIREABLE(AtStation_2_31) OR FIREABLE(AtStation_1_32) OR FIREABLE(AtStation_2_32) OR FIREABLE(AtStation_1_33) OR FIREABLE(AtStation_2_33) OR FIREABLE(AtStation_1_34) OR FIREABLE(AtStation_2_34) OR FIREABLE(AtStation_1_35) OR FIREABLE(AtStation_2_35) OR FIREABLE(AtStation_1_36) OR FIREABLE(AtStation_2_36) OR FIREABLE(AtStation_1_37) OR FIREABLE(AtStation_2_37) OR FIREABLE(AtStation_1_38) OR FIREABLE(AtStation_2_38) OR FIREABLE(AtStation_1_39) OR FIREABLE(AtStation_2_39) OR FIREABLE(AtStation_1_40) OR FIREABLE(AtStation_2_40)))) U G ((FIREABLE(TrainDecc_2_1_3_4_2_1_6) OR FIREABLE(TrainDecc_2_2_3_4_2_1_6) OR FIREABLE(TrainDecc_2_1_3_5_3_2_6) OR FIREABLE(TrainDecc_2_2_3_5_3_2_6) OR FIREABLE(TrainDecc_3_1_6_7_4_3_10) OR FIREABLE(TrainDecc_3_2_6_7_4_3_10) OR FIREABLE(TrainDecc_3_1_6_8_5_4_10) OR FIREABLE(TrainDecc_3_2_6_8_5_4_10) OR FIREABLE(TrainDecc_3_1_6_9_6_5_10) OR FIREABLE(TrainDecc_3_2_6_9_6_5_10) OR FIREABLE(TrainDecc_4_1_10_11_7_6_15) OR FIREABLE(TrainDecc_4_2_10_11_7_6_15) OR FIREABLE(TrainDecc_4_1_10_12_8_7_15) OR FIREABLE(TrainDecc_4_2_10_12_8_7_15) OR FIREABLE(TrainDecc_4_1_10_13_9_8_15) OR FIREABLE(TrainDecc_4_2_10_13_9_8_15) OR FIREABLE(TrainDecc_4_1_10_14_10_9_15) OR FIREABLE(TrainDecc_4_2_10_14_10_9_15))))))
lola: processed formula: A (X ((F (G ((FIREABLE(AtStation_1_5) OR FIREABLE(AtStation_2_5) OR FIREABLE(AtStation_1_6) OR FIREABLE(AtStation_2_6) OR FIREABLE(AtStation_1_7) OR FIREABLE(AtStation_2_7) OR FIREABLE(AtStation_1_8) OR FIREABLE(AtStation_2_8) OR FIREABLE(AtStation_1_9) OR FIREABLE(AtStation_2_9) OR FIREABLE(AtStation_1_10) OR FIREABLE(AtStation_2_10) OR FIREABLE(AtStation_1_11) OR FIREABLE(AtStation_... (shortened)
lola: processed formula length: 2813
lola: 1 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: the resulting B\xfcchi automaton has 6 states
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 1052 bytes per marking, with 29 unused bits
lola: using a prefix tree store (--store=prefix)
lola: Formula contains X operator; stubborn sets not applicable
lola: SEARCH
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: LTL model checker
lola: The net does not satisfy the given formula (language of the product automaton is nonempty).
lola: 18 markings, 23 edges
lola: ========================================
lola: subprocess 7 will run for 393 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A (G (X (G ((FIREABLE(TrainStable_1_1_1_2_1_0_3) OR FIREABLE(TrainStable_1_2_1_2_1_0_3) OR FIREABLE(TrainStable_1_1_1_3_2_1_3) OR FIREABLE(TrainStable_1_2_1_3_2_1_3) OR FIREABLE(TrainStable_1_1_1_4_3_2_3) OR FIREABLE(TrainStable_1_2_1_4_3_2_3) OR FIREABLE(TrainStable_1_1_1_5_4_3_3) OR FIREABLE(TrainStable_1_2_1_5_4_3_3) OR FIREABLE(TrainStable_1_1_1_6_5_4_3) OR FIREABLE(TrainStable_1_2_1_... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking LTL
lola: transforming LTL-Formula into a B\xfcchi-Automaton
lola: processed formula: A (G (X (G ((FIREABLE(TrainStable_1_1_1_2_1_0_3) OR FIREABLE(TrainStable_1_2_1_2_1_0_3) OR FIREABLE(TrainStable_1_1_1_3_2_1_3) OR FIREABLE(TrainStable_1_2_1_3_2_1_3) OR FIREABLE(TrainStable_1_1_1_4_3_2_3) OR FIREABLE(TrainStable_1_2_1_4_3_2_3) OR FIREABLE(TrainStable_1_1_1_5_4_3_3) OR FIREABLE(TrainStable_1_2_1_5_4_3_3) OR FIREABLE(TrainStable_1_1_1_6_5_4_3) OR FIREABLE(TrainStable_1_2_1_6_5_4_3) OR FIREABLE(TrainStable_1_1_1_7_6_5_3) OR FIREABLE(TrainStable_1_2_1_7_6_5_3) OR FIREABLE(TrainStable_1_1_1_8_7_6_3) OR FIREABLE(TrainStable_1_2_1_8_7_6_3) OR FIREABLE(TrainStable_1_1_1_9_8_7_3) OR FIREABLE(TrainStable_1_2_1_9_8_7_3) OR FIREABLE(TrainStable_1_1_1_10_9_8_3) OR FIREABLE(TrainStable_1_2_1_10_9_8_3) OR FIREABLE(TrainStable_1_1_1_11_10_9_3) OR FIREABLE(TrainStable_1_2_1_11_10_9_3) OR FIREABLE(TrainStable_1_1_1_12_11_10_3) OR FIREABLE(TrainStable_1_2_1_12_11_10_3) OR FIREABLE(TrainStable_1_1_1_13_12_11_3) OR FIREABLE(TrainStable_1_2_1_13_12_11_3) OR FIREABLE(TrainStable_1_1_1_14_13_12_3) OR FIREABLE(TrainStable_1_2_1_14_13_12_3) OR FIREABLE(TrainStable_1_1_1_15_14_13_3) OR FIREABLE(TrainStable_1_2_1_15_14_13_3) OR FIREABLE(TrainStable_1_1_1_16_15_14_3) OR FIREABLE(TrainStable_1_2_1_16_15_14_3) OR FIREABLE(TrainStable_1_1_1_17_16_15_3) OR FIREABLE(TrainStable_1_2_1_17_16_15_3) OR FIREABLE(TrainStable_1_1_1_18_17_16_3) OR FIREABLE(TrainStable_1_2_1_18_17_16_3) OR FIREABLE(TrainStable_1_1_1_19_18_17_3) OR FIREABLE(TrainStable_1_2_1_19_18_17_3) OR FIREABLE(TrainStable_1_1_1_20_19_18_3) OR FIREABLE(TrainStable_1_2_1_20_19_18_3) OR FIREABLE(TrainStable_1_1_1_21_20_19_3) OR FIREABLE(TrainStable_1_2_1_21_20_19_3) OR FIREABLE(TrainStable_1_1_1_22_21_20_3) OR FIREABLE(TrainStable_1_2_1_22_21_20_3) OR FIREABLE(TrainStable_1_1_1_23_22_21_3) OR FIREABLE(TrainStable_1_2_1_23_22_21_3) OR FIREABLE(TrainStable_1_1_1_24_23_22_3) OR FIREABLE(TrainStable_1_2_1_24_23_22_3) OR FIREABLE(TrainStable_1_1_1_25_24_23_3) OR FIREABLE(TrainStable_1_2_1_25_24_23_3) OR FIREABLE(TrainStable_1_1_1_26_25_24_3) OR FIREABLE(TrainStable_1_2_1_26_25_24_3) OR FIREABLE(TrainStable_1_1_1_27_26_25_3) OR FIREABLE(TrainStable_1_2_1_27_26_25_3) OR FIREABLE(TrainStable_1_1_1_28_27_26_3) OR FIREABLE(TrainStable_1_2_1_28_27_26_3) OR FIREABLE(TrainStable_1_1_1_29_28_27_3) OR FIREABLE(TrainStable_1_2_1_29_28_27_3) OR FIREABLE(TrainStable_1_1_1_30_29_28_3) OR FIREABLE(TrainStable_1_2_1_30_29_28_3) OR FIREABLE(TrainStable_1_1_1_31_30_29_3) OR FIREABLE(TrainStable_1_2_1_31_30_29_3) OR FIREABLE(TrainStable_1_1_1_32_31_30_3) OR FIREABLE(TrainStable_1_2_1_32_31_30_3) OR FIREABLE(TrainStable_1_1_1_33_32_31_3) OR FIREABLE(TrainStable_1_2_1_33_32_31_3) OR FIREABLE(TrainStable_1_1_1_34_33_32_3) OR FIREABLE(TrainStable_1_2_1_34_33_32_3) OR FIREABLE(TrainStable_1_1_1_35_34_33_3) OR FIREABLE(TrainStable_1_2_1_35_34_33_3) OR FIREABLE(TrainStable_1_1_1_36_35_34_3) OR FIREABLE(TrainStable_1_2_1_36_35_34_3) OR FIREABLE(TrainStable_1_1_1_37_36_35_3) OR FIREABLE(TrainStable_1_2_1_37_36_35_3) OR FIREABLE(TrainStable_1_1_1_38_37_36_3) OR FIREABLE(TrainStable_1_2_1_38_37_36_3) OR FIREABLE(TrainStable_1_1_1_39_38_37_3) OR FIREABLE(TrainStable_1_2_1_39_38_37_3) OR FIREABLE(TrainStable_1_1_1_40_39_38_3) OR FIREABLE(TrainStable_1_2_1_40_39_38_3) OR FIREABLE(TrainStable_2_1_3_6_4_3_6) OR FIREABLE(TrainStable_2_2_3_6_4_3_6) OR FIREABLE(TrainStable_2_1_3_7_5_4_6) OR FIREABLE(TrainStable_2_2_3_7_5_4_6) OR FIREABLE(TrainStable_2_1_3_8_6_5_6) OR FIREABLE(TrainStable_2_2_3_8_6_5_6) OR FIREABLE(TrainStable_2_1_3_9_7_6_6) OR FIREABLE(TrainStable_2_2_3_9_7_6_6) OR FIREABLE(TrainStable_3_1_6_10_7_6_10) OR FIREABLE(TrainStable_3_2_6_10_7_6_10) OR FIREABLE(TrainStable_3_1_6_11_8_7_10) OR FIREABLE(TrainStable_3_2_6_11_8_7_10) OR FIREABLE(TrainStable_3_1_6_12_9_8_10) OR FIREABLE(TrainStable_3_2_6_12_9_8_10) OR FIREABLE(TrainStable_3_1_6_13_10_9_10) OR FIREABLE(TrainStable_3_2_6_13_10_9_10) OR FIREABLE(TrainStable_3_1_6_14_11_10_10) OR FIREABLE(TrainStable_3_2_6_14_11_10_10) OR FIREABLE(TrainStable_4_1_10_15_11_10_15) OR FIREABLE(TrainStable_4_2_10_15_11_10_15) OR FIREABLE(TrainStable_4_1_10_16_12_11_15) OR FIREABLE(TrainStable_4_2_10_16_12_11_15) OR FIREABLE(TrainStable_4_1_10_17_13_12_15) OR FIREABLE(TrainStable_4_2_10_17_13_12_15) OR FIREABLE(TrainStable_4_1_10_18_14_13_15) OR FIREABLE(TrainStable_4_2_10_18_14_13_15) OR FIREABLE(TrainStable_4_1_10_19_15_14_15) OR FIREABLE(TrainStable_4_2_10_19_15_14_15) OR FIREABLE(TrainStable_4_1_10_20_16_15_15) OR FIREABLE(TrainStable_4_2_10_20_16_15_15) OR FIREABLE(TrainStable_4_1_10_21_17_16_15) OR FIREABLE(TrainStable_4_2_10_21_17_16_15) OR FIREABLE(TrainStable_4_1_10_22_18_17_15) OR FIREABLE(TrainStable_4_2_10_22_18_17_15) OR FIREABLE(TrainStable_4_1_10_23_19_18_15) OR FIREABLE(TrainStable_4_2_10_23_19_18_15) OR FIREABLE(TrainStable_4_1_10_24_20_19_15) OR FIREABLE(TrainStable_4_2_10_24_20_19_15) OR FIREABLE(TrainStable_4_1_10_25_21_20_15) OR FIREABLE(TrainStable_4_2_10_25_21_20_15) OR FIREABLE(TrainStable_4_1_10_26_22_21_15) OR FIREABLE(TrainStable_4_2_10_26_22_21_15) OR FIREABLE(TrainStable_4_1_10_27_23_22_15) OR FIREABLE(TrainStable_4_2_10_27_23_22_15) OR FIREABLE(TrainStable_4_1_10_28_24_23_15) OR FIREABLE(TrainStable_4_2_10_28_24_23_15) OR FIREABLE(TrainStable_4_1_10_29_25_24_15) OR FIREABLE(TrainStable_4_2_10_29_25_24_15) OR FIREABLE(TrainStable_4_1_10_30_26_25_15) OR FIREABLE(TrainStable_4_2_10_30_26_25_15) OR FIREABLE(TrainStable_4_1_10_31_27_26_15) OR FIREABLE(TrainStable_4_2_10_31_27_26_15) OR FIREABLE(TrainStable_4_1_10_32_28_27_15) OR FIREABLE(TrainStable_4_2_10_32_28_27_15) OR FIREABLE(TrainStable_4_1_10_33_29_28_15) OR FIREABLE(TrainStable_4_2_10_33_29_28_15) OR FIREABLE(TrainStable_4_1_10_34_30_29_15) OR FIREABLE(TrainStable_4_2_10_34_30_29_15))))))
lola: processed formula: A (G (X (G ((FIREABLE(TrainStable_1_1_1_2_1_0_3) OR FIREABLE(TrainStable_1_2_1_2_1_0_3) OR FIREABLE(TrainStable_1_1_1_3_2_1_3) OR FIREABLE(TrainStable_1_2_1_3_2_1_3) OR FIREABLE(TrainStable_1_1_1_4_3_2_3) OR FIREABLE(TrainStable_1_2_1_4_3_2_3) OR FIREABLE(TrainStable_1_1_1_5_4_3_3) OR FIREABLE(TrainStable_1_2_1_5_4_3_3) OR FIREABLE(TrainStable_1_1_1_6_5_4_3) OR FIREABLE(TrainStable_1_2_1_... (shortened)
lola: processed formula length: 5859
lola: 0 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: the resulting B\xfcchi automaton has 3 states
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 1052 bytes per marking, with 30 unused bits
lola: using a prefix tree store (--store=prefix)
lola: Formula contains X operator; stubborn sets not applicable
lola: SEARCH
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: LTL model checker
lola: The net does not satisfy the given formula (language of the product automaton is nonempty).
lola: 39 markings, 44 edges
lola: ========================================
lola: subprocess 8 will run for 442 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A (FIREABLE(TrainAcc_1_2_14_13_12_3))
lola: ========================================
lola: SUBTASK
lola: checking initial satisfaction
lola: processed formula: FIREABLE(TrainAcc_1_2_14_13_12_3)
lola: processed formula length: 33
lola: 1 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: processed formula with 0 atomic propositions
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: preprocessing
lola: The net violates the given property already in its initial state.
lola: 0 markings, 0 edges
lola: ========================================
lola: subprocess 9 will run for 505 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A (G ((F (G (FIREABLE(TrainStable_4_2_10_26_22_21_15))) U (FIREABLE(TrainAcc_1_2_32_31_30_3) U FIREABLE(TrainStable_1_1_1_15_14_13_3)))))
lola: ========================================
lola: SUBTASK
lola: checking LTL
lola: transforming LTL-Formula into a B\xfcchi-Automaton
lola: processed formula: A (G ((F (G (FIREABLE(TrainStable_4_2_10_26_22_21_15))) U (FIREABLE(TrainAcc_1_2_32_31_30_3) U FIREABLE(TrainStable_1_1_1_15_14_13_3)))))
lola: processed formula: A (G ((F (G (FIREABLE(TrainStable_4_2_10_26_22_21_15))) U (FIREABLE(TrainAcc_1_2_32_31_30_3) U FIREABLE(TrainStable_1_1_1_15_14_13_3)))))
lola: processed formula length: 137
lola: 0 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: the resulting B\xfcchi automaton has 7 states
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 1052 bytes per marking, with 29 unused bits
lola: using a prefix tree store (--store=prefix)
lola: using ltl preserving stubborn set method (--stubborn)
lola: SEARCH
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: LTL model checker
lola: The net does not satisfy the given formula (language of the product automaton is nonempty).
lola: 15 markings, 15 edges
lola: ========================================
lola: subprocess 10 will run for 590 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A (F (F (G (FIREABLE(TrainAcc_1_2_19_18_17_3)))))
lola: ========================================
lola: SUBTASK
lola: checking LTL
lola: transforming LTL-Formula into a B\xfcchi-Automaton
lola: processed formula: A (F (G (FIREABLE(TrainAcc_1_2_19_18_17_3))))
lola: processed formula: A (F (G (FIREABLE(TrainAcc_1_2_19_18_17_3))))
lola: processed formula length: 45
lola: 1 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: the resulting B\xfcchi automaton has 2 states
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 1052 bytes per marking, with 30 unused bits
lola: using a prefix tree store (--store=prefix)
lola: using ltl preserving stubborn set method (--stubborn)
lola: SEARCH
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: LTL model checker
lola: The net does not satisfy the given formula (language of the product automaton is nonempty).
lola: 16 markings, 17 edges
lola: ========================================
lola: subprocess 11 will run for 708 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A (FIREABLE(AtStation_2_37))
lola: ========================================
lola: SUBTASK
lola: checking initial satisfaction
lola: processed formula: FIREABLE(AtStation_2_37)
lola: processed formula length: 24
lola: 1 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: processed formula with 0 atomic propositions
lola: RUNNING
lola: SUBRESULT
lola: result: yes
lola: produced by: preprocessing
lola: The net satisfies the property already in its initial state.
lola: 0 markings, 0 edges
lola: ========================================
lola: subprocess 12 will run for 885 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A (FIREABLE(TrainAcc_2_2_18_16_15_6))
lola: ========================================
lola: SUBTASK
lola: checking initial satisfaction
lola: processed formula: FIREABLE(TrainAcc_2_2_18_16_15_6)
lola: processed formula length: 33
lola: 1 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: processed formula with 0 atomic propositions
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: preprocessing
lola: The net violates the given property already in its initial state.
lola: 0 markings, 0 edges
lola: ========================================
lola: subprocess 13 will run for 1180 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A (G (G ((X (FIREABLE(AtStation_2_27)) U G (FIREABLE(TrainStable_2_1_3_7_5_4_6))))))
lola: ========================================
lola: SUBTASK
lola: checking LTL
lola: transforming LTL-Formula into a B\xfcchi-Automaton
lola: processed formula: A (G (G ((X (FIREABLE(AtStation_2_27)) U G (FIREABLE(TrainStable_2_1_3_7_5_4_6))))))
lola: processed formula: A (G (G ((X (FIREABLE(AtStation_2_27)) U G (FIREABLE(TrainStable_2_1_3_7_5_4_6))))))
lola: processed formula length: 84
lola: 0 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: the resulting B\xfcchi automaton has 8 states
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 1052 bytes per marking, with 28 unused bits
lola: using a prefix tree store (--store=prefix)
lola: Formula contains X operator; stubborn sets not applicable
lola: SEARCH
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: LTL model checker
lola: The net does not satisfy the given formula (language of the product automaton is nonempty).
lola: 16 markings, 16 edges
lola: ========================================
lola: subprocess 14 will run for 1770 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A ((X (F (F (FIREABLE(TrainAcc_1_1_7_6_5_3)))) U G ((FIREABLE(TrainStable_1_1_1_5_4_3_3) U FIREABLE(AtStation_1_34)))))
lola: ========================================
lola: SUBTASK
lola: checking LTL
lola: transforming LTL-Formula into a B\xfcchi-Automaton
lola: processed formula: A ((X (F (FIREABLE(TrainAcc_1_1_7_6_5_3))) U G ((FIREABLE(TrainStable_1_1_1_5_4_3_3) U FIREABLE(AtStation_1_34)))))
lola: processed formula: A ((X (F (FIREABLE(TrainAcc_1_1_7_6_5_3))) U G ((FIREABLE(TrainStable_1_1_1_5_4_3_3) U FIREABLE(AtStation_1_34)))))
lola: processed formula length: 115
lola: 1 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: the resulting B\xfcchi automaton has 6 states
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 1052 bytes per marking, with 29 unused bits
lola: using a prefix tree store (--store=prefix)
lola: Formula contains X operator; stubborn sets not applicable
lola: SEARCH
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: LTL model checker
lola: The net does not satisfy the given formula (language of the product automaton is nonempty).
lola: 15 markings, 15 edges
lola: ========================================
lola: subprocess 15 will run for 3540 seconds at most (--localtimelimit=-1)
lola: ========================================
lola: ...considering subproblem: A (FIREABLE(TrainStable_4_2_10_15_11_10_15))
lola: ========================================
lola: SUBTASK
lola: checking initial satisfaction
lola: processed formula: FIREABLE(TrainStable_4_2_10_15_11_10_15)
lola: processed formula length: 40
lola: 1 rewrites
lola: formula mentions 0 of 474 places; total mentions: 0
lola: closed formula file BART-PT-002-LTLFireability.task
lola: processed formula with 0 atomic propositions
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: produced by: preprocessing
lola: The net violates the given property already in its initial state.
lola: 0 markings, 0 edges
lola: ========================================
lola: RESULT
lola:
SUMMARY: no yes no no no no no no no no no yes no no no no
FORMULA BART-PT-002-LTLFireability-0 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-1 TRUE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-2 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-3 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-4 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-5 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-6 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-7 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-8 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-9 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-10 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-11 TRUE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-12 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-13 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-14 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
FORMULA BART-PT-002-LTLFireability-15 FALSE TECHNIQUES COLLATERAL_PROCESSING EXPLICIT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL USE_NUPN
----- Kill lola and sara stdout -----
----- Kill lola and sara stderr -----
----- Finished stdout -----
----- Finished stderr -----

Sequence of Actions to be Executed by the VM

This is useful if one wants to reexecute the tool in the VM from the submitted image disk.

set -x
# this is for BenchKit: configuration of major elements for the test
export BK_INPUT="BART-PT-002"
export BK_EXAMINATION="LTLFireability"
export BK_TOOL="irma4mcc-full"
export BK_RESULT_DIR="/tmp/BK_RESULTS/OUTPUTS"
export BK_TIME_CONFINEMENT="3600"
export BK_MEMORY_CONFINEMENT="16384"

# this is specific to your benchmark or test

export BIN_DIR="$HOME/BenchKit/bin"

# remove the execution directoty if it exists (to avoid increse of .vmdk images)
if [ -d execution ] ; then
rm -rf execution
fi

tar xzf /home/mcc/BenchKit/INPUTS/BART-PT-002.tgz
mv BART-PT-002 execution
cd execution
pwd
ls -lh

# this is for BenchKit: explicit launching of the test
echo "====================================================================="
echo " Generated by BenchKit 2-3637"
echo " Executing tool irma4mcc-full"
echo " Input is BART-PT-002, examination is LTLFireability"
echo " Time confinement is $BK_TIME_CONFINEMENT seconds"
echo " Memory confinement is 16384 MBytes"
echo " Number of cores is 4"
echo " Run identifier is r222-ebro-152732363900018"
echo "====================================================================="
echo
echo "--------------------"
echo "content from stdout:"
echo
echo "=== Data for post analysis generated by BenchKit (invocation template)"
echo
if [ "LTLFireability" = "UpperBounds" ] ; then
echo "The expected result is a vector of positive values"
echo NUM_VECTOR
elif [ "LTLFireability" != "StateSpace" ] ; then
echo "The expected result is a vector of booleans"
echo BOOL_VECTOR
else
echo "no data necessary for post analysis"
fi
echo
if [ -f "LTLFireability.txt" ] ; then
echo "here is the order used to build the result vector(from text file)"
for x in $(grep Property LTLFireability.txt | cut -d ' ' -f 2 | sort -u) ; do
echo "FORMULA_NAME $x"
done
elif [ -f "LTLFireability.xml" ] ; then # for cunf (txt files deleted;-)
echo echo "here is the order used to build the result vector(from xml file)"
for x in $(grep '' LTLFireability.xml | cut -d '>' -f 2 | cut -d '<' -f 1 | sort -u) ; do
echo "FORMULA_NAME $x"
done
fi
echo
echo "=== Now, execution of the tool begins"
echo
echo -n "BK_START "
date -u +%s%3N
echo
timeout -s 9 $BK_TIME_CONFINEMENT bash -c "/home/mcc/BenchKit/BenchKit_head.sh 2> STDERR ; echo ; echo -n \"BK_STOP \" ; date -u +%s%3N"
if [ $? -eq 137 ] ; then
echo
echo "BK_TIME_CONFINEMENT_REACHED"
fi
echo
echo "--------------------"
echo "content from stderr:"
echo
cat STDERR ;