fond
Model Checking Contest @ Petri Nets 2016
6th edition, Toruń, Poland, June 21, 2016
Execution of r170kn-ebro-146433132800337
Last Updated
June 30, 2016

About the Execution of LoLa for S_BridgeAndVehicles-PT-V50P20N20

Execution Summary
Max Memory
Used (MB)
Time wait (ms) CPU Usage (ms) I/O Wait (ms) Computed Result Execution
Status
7881.200 2358637.00 2374553.00 370.60 T?F??FTFFFFFFTFF normal

Execution Chart

We display below the execution chart for this examination (boot time has been removed).

Trace from the execution

Waiting for the VM to be ready (probing ssh)
..................
=====================================================================
Generated by BenchKit 2-2979
Executing tool lola
Input is S_BridgeAndVehicles-PT-V50P20N20, examination is CTLFireability
Time confinement is 3600 seconds
Memory confinement is 16384 MBytes
Number of cores is 4
Run identifier is r170kn-ebro-146433132800337
=====================================================================


--------------------
content from stdout:

=== Data for post analysis generated by BenchKit (invocation template)

The expected result is a vector of booleans
BOOL_VECTOR

here is the order used to build the result vector(from text file)
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-0
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-1
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-10
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-11
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-12
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-13
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-14
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-15
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-2
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-3
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-4
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-5
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-6
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-7
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-8
FORMULA_NAME BridgeAndVehicles-COL-V50P20N20-CTLFireability-9

=== Now, execution of the tool begins

BK_START 1464455742847

bkconf 3600
===========================================================================================
===========================================================================================
S_BridgeAndVehicles-PT-V50P20N20: translating Petri net model.pnml into LoLA format
S_BridgeAndVehicles-PT-V50P20N20: translating formula CTLFireability into LoLA format
===========================================================================================
/home/mcc/BenchKit/bin/pnml2lola.py model.pnml > model.pnml.lola
===========================================================================================
/home/mcc/BenchKit/bin/formula2lola.py CTLFireability.xml
touch formulae;


in benchkit_head lolaszeit 3532
CTLFireability @ S_BridgeAndVehicles-PT-V50P20N20
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-0 TRUE TECHNIQUES PARALLEL_PROCESSING EXPLICIT SAT_SMT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-1 CANNOT_COMPUTE
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-2 FALSE TECHNIQUES PARALLEL_PROCESSING EXPLICIT SAT_SMT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-3 FALSE TECHNIQUES PARALLEL_PROCESSING EXPLICIT SAT_SMT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-4 FALSE TECHNIQUES PARALLEL_PROCESSING EXPLICIT SAT_SMT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-5 FALSE TECHNIQUES PARALLEL_PROCESSING EXPLICIT SAT_SMT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-6 FALSE TECHNIQUES PARALLEL_PROCESSING EXPLICIT SAT_SMT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-7 TRUE TECHNIQUES PARALLEL_PROCESSING EXPLICIT SAT_SMT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-8 FALSE TECHNIQUES PARALLEL_PROCESSING EXPLICIT SAT_SMT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-9 FALSE TECHNIQUES PARALLEL_PROCESSING EXPLICIT SAT_SMT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-10 FALSE TECHNIQUES PARALLEL_PROCESSING EXPLICIT SAT_SMT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-11 CANNOT_COMPUTE
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-12 CANNOT_COMPUTE
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-13 FALSE TECHNIQUES PARALLEL_PROCESSING EXPLICIT SAT_SMT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-14 TRUE TECHNIQUES PARALLEL_PROCESSING EXPLICIT SAT_SMT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL
FORMULA BridgeAndVehicles-COL-V50P20N20-CTLFireability-15 FALSE TECHNIQUES PARALLEL_PROCESSING EXPLICIT SAT_SMT STATE_COMPRESSION STUBBORN_SETS TOPOLOGICAL
lola: LoLA will run for 3532 seconds at most (--timelimit)
lola: NET
lola: reading net from model.pnml.lola
lola: finished parsing
lola: closed net file model.pnml.lola
lola: 2486/65536 symbol table entries, 36 collisions
lola: preprocessing...
lola: finding significant places
lola: 138 places, 2348 transitions, 131 significant places
lola: computing forward-conflicting sets
lola: computing back-conflicting sets
lola: 2693 transition conflict sets
lola: TASK
lola: reading formula from BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: read: AF (EX (AF ((((((((((((((((((((((((((((((((((((((((((((((((((FIREABLE(autorisation_A_1_1) OR FIREABLE(autorisation_A_1_2)) OR FIREABLE(autorisation_A_1_3)) OR FIREABLE(autorisation_A_1_4)) OR FIREABLE(autorisation_A_1_5)) OR FIREABLE(autorisation_A_1_6)) OR FIREABLE(autorisation_A_1_7)) OR FIREABLE(autorisation_A_1_8)) OR FIREABLE(autorisation_A_1_9)) OR FIREABLE(autorisation_A_1_10)) OR FIREABLE(... (shortened)
lola: formula length: 567007
lola: computing a collection of formulas
lola: RUNNING
lola: subprocess 0 will run for 199 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: AF (EX (AF ((FIREABLE(autorisation_A_1_1) OR (FIREABLE(autorisation_A_1_2) OR (FIREABLE(autorisation_A_1_3) OR (FIREABLE(autorisation_A_1_4) OR (FIREABLE(autorisation_A_1_5) OR (FIREABLE(autorisation_A_1_6) OR (FIREABLE(autorisation_A_1_7) OR (FIREABLE(autorisation_A_1_8) OR (FIREABLE(autorisation_A_1_9) OR (FIREABLE(autorisation_A_1_10) OR (FIREABLE(autorisation_A_1_11) OR (FIREABLE(autorisation_... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: A(TRUE U EX(A(TRUE U (FIREABLE(autorisation_A_1_1) OR (FIREABLE(autorisation_A_1_2) OR (FIREABLE(autorisation_A_1_3) OR (FIREABLE(autorisation_A_1_4) OR (FIREABLE(autorisation_A_1_5) OR (FIREABLE(autorisation_A_1_6) OR (FIREABLE(autorisation_A_1_7) OR (FIREABLE(autorisation_A_1_8) OR (FIREABLE(autorisation_A_1_9) OR (FIREABLE(autorisation_A_1_10) OR (FIREABLE(autorisation_A_1_11) OR (FIREABLE(auto... (shortened)
lola: processed formula length: 1759
lola: 7756311 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 2 significant temporal operators and needs 9 bytes of payload
lola: SUBRESULT
lola: result: yes
lola: The net satisfies the given formula.
lola: ========================================
lola: subprocess 1 will run for 209 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: AF ((FIREABLE(timeout_A_1_0_0_1) OR (FIREABLE(timeout_A_1_1_0_1) OR (FIREABLE(timeout_A_1_2_0_1) OR (FIREABLE(timeout_A_1_3_0_1) OR (FIREABLE(timeout_A_1_4_0_1) OR (FIREABLE(timeout_A_1_5_0_1) OR (FIREABLE(timeout_A_1_6_0_1) OR (FIREABLE(timeout_A_1_7_0_1) OR (FIREABLE(timeout_A_1_8_0_1) OR (FIREABLE(timeout_A_1_9_0_1) OR (FIREABLE(timeout_A_1_10_0_1) OR (FIREABLE(timeout_A_1_11_0_1) OR (FIREABLE(... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: A(TRUE U (FIREABLE(timeout_A_1_0_0_1) OR (FIREABLE(timeout_A_1_1_0_1) OR (FIREABLE(timeout_A_1_2_0_1) OR (FIREABLE(timeout_A_1_3_0_1) OR (FIREABLE(timeout_A_1_4_0_1) OR (FIREABLE(timeout_A_1_5_0_1) OR (FIREABLE(timeout_A_1_6_0_1) OR (FIREABLE(timeout_A_1_7_0_1) OR (FIREABLE(timeout_A_1_8_0_1) OR (FIREABLE(timeout_A_1_9_0_1) OR (FIREABLE(timeout_A_1_10_0_1) OR (FIREABLE(timeout_A_1_11_0_1) OR (FIRE... (shortened)
lola: processed formula length: 36065
lola: 7756309 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 1 significant temporal operators and needs 5 bytes of payload
lola: local time limit reached - aborting
lola: Child process aborted or communication problem between parent and child process
lola: subprocess 2 will run for 209 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: (AG (EX ((! FIREABLE(altern_cpt_1_20) AND ! FIREABLE(altern_cpt_2_20)))) OR (! FIREABLE(timeout_B_2_0_1_0) AND (! FIREABLE(timeout_B_2_1_1_0) AND (! FIREABLE(timeout_B_2_2_1_0) AND (! FIREABLE(timeout_B_2_3_1_0) AND (! FIREABLE(timeout_B_2_4_1_0) AND (! FIREABLE(timeout_B_2_5_1_0) AND (! FIREABLE(timeout_B_2_6_1_0) AND (! FIREABLE(timeout_B_2_7_1_0) AND (! FIREABLE(timeout_B_2_8_1_0) AND (! FIREAB... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking a Boolean combination of formulas
lola: RUNNING
lola: subprocess 2 will run for 209 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: AG (EX ((! FIREABLE(altern_cpt_1_20) AND ! FIREABLE(altern_cpt_2_20))))
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: !(E(TRUE U !(EX((! FIREABLE(altern_cpt_1_20) AND ! FIREABLE(altern_cpt_2_20))))))
lola: processed formula length: 81
lola: 7756310 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 1 significant temporal operators and needs 5 bytes of payload
lola: SUBRESULT
lola: result: no
lola: The net does not satisfy the given formula.
lola: ========================================
lola: subprocess 3 will run for 225 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: (! FIREABLE(timeout_B_2_0_1_0) AND (! FIREABLE(timeout_B_2_1_1_0) AND (! FIREABLE(timeout_B_2_2_1_0) AND (! FIREABLE(timeout_B_2_3_1_0) AND (! FIREABLE(timeout_B_2_4_1_0) AND (! FIREABLE(timeout_B_2_5_1_0) AND (! FIREABLE(timeout_B_2_6_1_0) AND (! FIREABLE(timeout_B_2_7_1_0) AND (! FIREABLE(timeout_B_2_8_1_0) AND (! FIREABLE(timeout_B_2_9_1_0) AND (! FIREABLE(timeout_B_2_10_1_0) AND (! FIREABLE(ti... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking initial satisfaction
lola: processed formula with 0 atomic propositions
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: The net violates the given property already in its initial state.
lola: ========================================
lola: SUBRESULT
lola: result: no
lola: The Boolean predicate is false.
lola: ========================================
lola: subprocess 3 will run for 225 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: (AF ((FIREABLE(altern_cpt_1_20) OR (FIREABLE(altern_cpt_2_20) OR ((FIREABLE(enregistrement_A_0) OR (FIREABLE(enregistrement_A_1) OR (FIREABLE(enregistrement_A_2) OR (FIREABLE(enregistrement_A_3) OR (FIREABLE(enregistrement_A_4) OR (FIREABLE(enregistrement_A_5) OR (FIREABLE(enregistrement_A_6) OR (FIREABLE(enregistrement_A_7) OR (FIREABLE(enregistrement_A_8) OR (FIREABLE(enregistrement_A_9) OR (FIR... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking a Boolean combination of formulas
lola: RUNNING
lola: subprocess 3 will run for 225 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: AF ((FIREABLE(altern_cpt_1_20) OR (FIREABLE(altern_cpt_2_20) OR ((FIREABLE(enregistrement_A_0) OR (FIREABLE(enregistrement_A_1) OR (FIREABLE(enregistrement_A_2) OR (FIREABLE(enregistrement_A_3) OR (FIREABLE(enregistrement_A_4) OR (FIREABLE(enregistrement_A_5) OR (FIREABLE(enregistrement_A_6) OR (FIREABLE(enregistrement_A_7) OR (FIREABLE(enregistrement_A_8) OR (FIREABLE(enregistrement_A_9) OR (FIRE... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: A(TRUE U (FIREABLE(altern_cpt_1_20) OR (FIREABLE(altern_cpt_2_20) OR ((FIREABLE(enregistrement_A_0) OR (FIREABLE(enregistrement_A_1) OR (FIREABLE(enregistrement_A_2) OR (FIREABLE(enregistrement_A_3) OR (FIREABLE(enregistrement_A_4) OR (FIREABLE(enregistrement_A_5) OR (FIREABLE(enregistrement_A_6) OR (FIREABLE(enregistrement_A_7) OR (FIREABLE(enregistrement_A_8) OR (FIREABLE(enregistrement_A_9) OR ... (shortened)
lola: processed formula length: 3680
lola: 7756309 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 1 significant temporal operators and needs 5 bytes of payload
lola: SUBRESULT
lola: result: no
lola: The net does not satisfy the given formula.
lola: ========================================
lola: SUBRESULT
lola: result: no
lola: The Boolean predicate is false.
lola: ========================================
lola: subprocess 4 will run for 241 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: AX ((EF ((FIREABLE(liberation_B) OR (FIREABLE(autorisation_A_1_1) OR (FIREABLE(autorisation_A_1_2) OR (FIREABLE(autorisation_A_1_3) OR (FIREABLE(autorisation_A_1_4) OR (FIREABLE(autorisation_A_1_5) OR (FIREABLE(autorisation_A_1_6) OR (FIREABLE(autorisation_A_1_7) OR (FIREABLE(autorisation_A_1_8) OR (FIREABLE(autorisation_A_1_9) OR (FIREABLE(autorisation_A_1_10) OR (FIREABLE(autorisation_A_1_11) OR... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: AX((E(TRUE U (FIREABLE(liberation_B) OR (FIREABLE(autorisation_A_1_1) OR (FIREABLE(autorisation_A_1_2) OR (FIREABLE(autorisation_A_1_3) OR (FIREABLE(autorisation_A_1_4) OR (FIREABLE(autorisation_A_1_5) OR (FIREABLE(autorisation_A_1_6) OR (FIREABLE(autorisation_A_1_7) OR (FIREABLE(autorisation_A_1_8) OR (FIREABLE(autorisation_A_1_9) OR (FIREABLE(autorisation_A_1_10) OR (FIREABLE(autorisation_A_1_11... (shortened)
lola: processed formula length: 3569
lola: 7756311 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 2 significant temporal operators and needs 9 bytes of payload
lola: SUBRESULT
lola: result: no
lola: The net does not satisfy the given formula.
lola: ========================================
lola: subprocess 5 will run for 263 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: (AF (EX (((FIREABLE(enregistrement_B_0) OR (FIREABLE(enregistrement_B_1) OR (FIREABLE(enregistrement_B_2) OR (FIREABLE(enregistrement_B_3) OR (FIREABLE(enregistrement_B_4) OR (FIREABLE(enregistrement_B_5) OR (FIREABLE(enregistrement_B_6) OR (FIREABLE(enregistrement_B_7) OR (FIREABLE(enregistrement_B_8) OR (FIREABLE(enregistrement_B_9) OR (FIREABLE(enregistrement_B_10) OR (FIREABLE(enregistrement_B... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking a Boolean combination of formulas
lola: RUNNING
lola: subprocess 5 will run for 263 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: AF (EX (((FIREABLE(enregistrement_B_0) OR (FIREABLE(enregistrement_B_1) OR (FIREABLE(enregistrement_B_2) OR (FIREABLE(enregistrement_B_3) OR (FIREABLE(enregistrement_B_4) OR (FIREABLE(enregistrement_B_5) OR (FIREABLE(enregistrement_B_6) OR (FIREABLE(enregistrement_B_7) OR (FIREABLE(enregistrement_B_8) OR (FIREABLE(enregistrement_B_9) OR (FIREABLE(enregistrement_B_10) OR (FIREABLE(enregistrement_B_... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: A(TRUE U EX(((FIREABLE(enregistrement_B_0) OR (FIREABLE(enregistrement_B_1) OR (FIREABLE(enregistrement_B_2) OR (FIREABLE(enregistrement_B_3) OR (FIREABLE(enregistrement_B_4) OR (FIREABLE(enregistrement_B_5) OR (FIREABLE(enregistrement_B_6) OR (FIREABLE(enregistrement_B_7) OR (FIREABLE(enregistrement_B_8) OR (FIREABLE(enregistrement_B_9) OR (FIREABLE(enregistrement_B_10) OR (FIREABLE(enregistremen... (shortened)
lola: processed formula length: 1812
lola: 7756310 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 1 significant temporal operators and needs 5 bytes of payload
lola: SUBRESULT
lola: result: no
lola: The net does not satisfy the given formula.
lola: ========================================
lola: SUBRESULT
lola: result: no
lola: The Boolean predicate is false.
lola: ========================================
lola: subprocess 6 will run for 289 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: AG (((AX ((FIREABLE(decision_1_0) OR (FIREABLE(decision_2_0) OR (FIREABLE(decision_1_1) OR (FIREABLE(decision_2_1) OR (FIREABLE(decision_1_2) OR (FIREABLE(decision_2_2) OR (FIREABLE(decision_1_3) OR (FIREABLE(decision_2_3) OR (FIREABLE(decision_1_4) OR (FIREABLE(decision_2_4) OR (FIREABLE(decision_1_5) OR (FIREABLE(decision_2_5) OR (FIREABLE(decision_1_6) OR (FIREABLE(decision_2_6) OR (FIREABLE(de... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: !(E(TRUE U !(((AX((FIREABLE(decision_1_0) OR (FIREABLE(decision_2_0) OR (FIREABLE(decision_1_1) OR (FIREABLE(decision_2_1) OR (FIREABLE(decision_1_2) OR (FIREABLE(decision_2_2) OR (FIREABLE(decision_1_3) OR (FIREABLE(decision_2_3) OR (FIREABLE(decision_1_4) OR (FIREABLE(decision_2_4) OR (FIREABLE(decision_1_5) OR (FIREABLE(decision_2_5) OR (FIREABLE(decision_1_6) OR (FIREABLE(decision_2_6) OR (FIR... (shortened)
lola: processed formula length: 12145
lola: 7756310 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 1 significant temporal operators and needs 5 bytes of payload
lola: SUBRESULT
lola: result: no
lola: The net does not satisfy the given formula.
lola: ========================================
lola: subprocess 7 will run for 321 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: EG (((! FIREABLE(autorisation_A_1_1) AND (! FIREABLE(autorisation_A_1_2) AND (! FIREABLE(autorisation_A_1_3) AND (! FIREABLE(autorisation_A_1_4) AND (! FIREABLE(autorisation_A_1_5) AND (! FIREABLE(autorisation_A_1_6) AND (! FIREABLE(autorisation_A_1_7) AND (! FIREABLE(autorisation_A_1_8) AND (! FIREABLE(autorisation_A_1_9) AND (! FIREABLE(autorisation_A_1_10) AND (! FIREABLE(autorisation_A_1_11) A... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: !(A(TRUE U !(((! FIREABLE(autorisation_A_1_1) AND (! FIREABLE(autorisation_A_1_2) AND (! FIREABLE(autorisation_A_1_3) AND (! FIREABLE(autorisation_A_1_4) AND (! FIREABLE(autorisation_A_1_5) AND (! FIREABLE(autorisation_A_1_6) AND (! FIREABLE(autorisation_A_1_7) AND (! FIREABLE(autorisation_A_1_8) AND (! FIREABLE(autorisation_A_1_9) AND (! FIREABLE(autorisation_A_1_10) AND (! FIREABLE(autorisation_... (shortened)
lola: processed formula length: 87361
lola: 7756309 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 1 significant temporal operators and needs 5 bytes of payload
lola: SUBRESULT
lola: result: yes
lola: The net satisfies the given formula.
lola: ========================================
lola: subprocess 8 will run for 361 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: (FIREABLE(altern_cpt_1_20) OR (FIREABLE(altern_cpt_2_20) OR EG (! FIREABLE(liberation_B))))
lola: ========================================
lola: SUBTASK
lola: checking a Boolean combination of formulas
lola: RUNNING
lola: subprocess 8 will run for 361 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: FIREABLE(altern_cpt_1_20)
lola: ========================================
lola: SUBTASK
lola: checking initial satisfaction
lola: processed formula with 0 atomic propositions
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: The net violates the given property already in its initial state.
lola: ========================================
lola: subprocess 9 will run for 413 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: FIREABLE(altern_cpt_2_20)
lola: ========================================
lola: SUBTASK
lola: checking initial satisfaction
lola: processed formula with 0 atomic propositions
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: RUNNING
lola: SUBRESULT
lola: result: no
lola: The net violates the given property already in its initial state.
lola: ========================================
lola: subprocess 10 will run for 482 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: EG (! FIREABLE(liberation_B))
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: !(A(TRUE U !(! FIREABLE(liberation_B))))
lola: processed formula length: 40
lola: 7756309 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 1 significant temporal operators and needs 5 bytes of payload
lola: SUBRESULT
lola: result: no
lola: The net does not satisfy the given formula.
lola: ========================================
lola: SUBRESULT
lola: result: no
lola: The Boolean predicate is false.
lola: ========================================
lola: subprocess 9 will run for 405 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: E((EG ((FIREABLE(altern_cpt_1_20) OR FIREABLE(altern_cpt_2_20))) OR ((FIREABLE(enregistrement_A_0) OR (FIREABLE(enregistrement_A_1) OR (FIREABLE(enregistrement_A_2) OR (FIREABLE(enregistrement_A_3) OR (FIREABLE(enregistrement_A_4) OR (FIREABLE(enregistrement_A_5) OR (FIREABLE(enregistrement_A_6) OR (FIREABLE(enregistrement_A_7) OR (FIREABLE(enregistrement_A_8) OR (FIREABLE(enregistrement_A_9) OR (... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: E((!(A(TRUE U !((FIREABLE(altern_cpt_1_20) OR FIREABLE(altern_cpt_2_20))))) OR ((FIREABLE(enregistrement_A_0) OR (FIREABLE(enregistrement_A_1) OR (FIREABLE(enregistrement_A_2) OR (FIREABLE(enregistrement_A_3) OR (FIREABLE(enregistrement_A_4) OR (FIREABLE(enregistrement_A_5) OR (FIREABLE(enregistrement_A_6) OR (FIREABLE(enregistrement_A_7) OR (FIREABLE(enregistrement_A_8) OR (FIREABLE(enregistremen... (shortened)
lola: processed formula length: 75862
lola: 7756311 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 3 significant temporal operators and needs 13 bytes of payload
lola: SUBRESULT
lola: result: no
lola: The net does not satisfy the given formula.
lola: ========================================
lola: subprocess 10 will run for 473 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: AG (AF ((FIREABLE(altern_cpt_1_20) OR FIREABLE(altern_cpt_2_20))))
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: !(E(TRUE U !(A(TRUE U (FIREABLE(altern_cpt_1_20) OR FIREABLE(altern_cpt_2_20))))))
lola: processed formula length: 82
lola: 7756310 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 2 significant temporal operators and needs 9 bytes of payload
lola: SUBRESULT
lola: result: no
lola: The net does not satisfy the given formula.
lola: ========================================
lola: subprocess 11 will run for 561 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: EF ((A((FIREABLE(timeout_B_2_0_1_0) OR (FIREABLE(timeout_B_2_1_1_0) OR (FIREABLE(timeout_B_2_2_1_0) OR (FIREABLE(timeout_B_2_3_1_0) OR (FIREABLE(timeout_B_2_4_1_0) OR (FIREABLE(timeout_B_2_5_1_0) OR (FIREABLE(timeout_B_2_6_1_0) OR (FIREABLE(timeout_B_2_7_1_0) OR (FIREABLE(timeout_B_2_8_1_0) OR (FIREABLE(timeout_B_2_9_1_0) OR (FIREABLE(timeout_B_2_10_1_0) OR (FIREABLE(timeout_B_2_11_1_0) OR (FIREAB... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: E(TRUE U (A((FIREABLE(timeout_B_2_0_1_0) OR (FIREABLE(timeout_B_2_1_1_0) OR (FIREABLE(timeout_B_2_2_1_0) OR (FIREABLE(timeout_B_2_3_1_0) OR (FIREABLE(timeout_B_2_4_1_0) OR (FIREABLE(timeout_B_2_5_1_0) OR (FIREABLE(timeout_B_2_6_1_0) OR (FIREABLE(timeout_B_2_7_1_0) OR (FIREABLE(timeout_B_2_8_1_0) OR (FIREABLE(timeout_B_2_9_1_0) OR (FIREABLE(timeout_B_2_10_1_0) OR (FIREABLE(timeout_B_2_11_1_0) OR (F... (shortened)
lola: processed formula length: 113292
lola: 7756310 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 2 significant temporal operators and needs 9 bytes of payload
lola: local time limit reached - aborting
lola: Child process aborted or communication problem between parent and child process
lola: subprocess 12 will run for 561 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: (AF ((! FIREABLE(basculement_1) AND (! FIREABLE(basculement_2) AND (! FIREABLE(enregistrement_A_0) AND (! FIREABLE(enregistrement_A_1) AND (! FIREABLE(enregistrement_A_2) AND (! FIREABLE(enregistrement_A_3) AND (! FIREABLE(enregistrement_A_4) AND (! FIREABLE(enregistrement_A_5) AND (! FIREABLE(enregistrement_A_6) AND (! FIREABLE(enregistrement_A_7) AND (! FIREABLE(enregistrement_A_8) AND (! FIREAB... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking a Boolean combination of formulas
lola: RUNNING
lola: subprocess 12 will run for 561 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: AF ((! FIREABLE(basculement_1) AND (! FIREABLE(basculement_2) AND (! FIREABLE(enregistrement_A_0) AND (! FIREABLE(enregistrement_A_1) AND (! FIREABLE(enregistrement_A_2) AND (! FIREABLE(enregistrement_A_3) AND (! FIREABLE(enregistrement_A_4) AND (! FIREABLE(enregistrement_A_5) AND (! FIREABLE(enregistrement_A_6) AND (! FIREABLE(enregistrement_A_7) AND (! FIREABLE(enregistrement_A_8) AND (! FIREABL... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: A(TRUE U (! FIREABLE(basculement_1) AND (! FIREABLE(basculement_2) AND (! FIREABLE(enregistrement_A_0) AND (! FIREABLE(enregistrement_A_1) AND (! FIREABLE(enregistrement_A_2) AND (! FIREABLE(enregistrement_A_3) AND (! FIREABLE(enregistrement_A_4) AND (! FIREABLE(enregistrement_A_5) AND (! FIREABLE(enregistrement_A_6) AND (! FIREABLE(enregistrement_A_7) AND (! FIREABLE(enregistrement_A_8) AND (! FI... (shortened)
lola: processed formula length: 1995
lola: 7756309 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 1 significant temporal operators and needs 5 bytes of payload
lola: local time limit reached - aborting
lola: caught signal User defined signal 1 - aborting LoLA
lola: local time limit reached - aborting
lola: Child process aborted or communication problem between parent and child process
lola: subprocess 13 will run for 562 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: EG ((EG (! FIREABLE(liberation_A)) OR EG (((FIREABLE(autorisation_B_2_1) OR (FIREABLE(autorisation_B_2_2) OR (FIREABLE(autorisation_B_2_3) OR (FIREABLE(autorisation_B_2_4) OR (FIREABLE(autorisation_B_2_5) OR (FIREABLE(autorisation_B_2_6) OR (FIREABLE(autorisation_B_2_7) OR (FIREABLE(autorisation_B_2_8) OR (FIREABLE(autorisation_B_2_9) OR (FIREABLE(autorisation_B_2_10) OR (FIREABLE(autorisation_B_2... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: !(A(TRUE U !((!(A(TRUE U !(! FIREABLE(liberation_A)))) OR !(A(TRUE U !(((FIREABLE(autorisation_B_2_1) OR (FIREABLE(autorisation_B_2_2) OR (FIREABLE(autorisation_B_2_3) OR (FIREABLE(autorisation_B_2_4) OR (FIREABLE(autorisation_B_2_5) OR (FIREABLE(autorisation_B_2_6) OR (FIREABLE(autorisation_B_2_7) OR (FIREABLE(autorisation_B_2_8) OR (FIREABLE(autorisation_B_2_9) OR (FIREABLE(autorisation_B_2_10) ... (shortened)
lola: processed formula length: 2954
lola: 7756311 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 3 significant temporal operators and needs 13 bytes of payload
lola: SUBRESULT
lola: result: no
lola: The net does not satisfy the given formula.
lola: ========================================
lola: subprocess 14 will run for 813 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: ((! FIREABLE(liberation_A) OR (EG (! FIREABLE(liberation_A)) AND ! FIREABLE(liberation_B))) AND E(AG ((FIREABLE(autorisation_A_1_1) OR (FIREABLE(autorisation_A_1_2) OR (FIREABLE(autorisation_A_1_3) OR (FIREABLE(autorisation_A_1_4) OR (FIREABLE(autorisation_A_1_5) OR (FIREABLE(autorisation_A_1_6) OR (FIREABLE(autorisation_A_1_7) OR (FIREABLE(autorisation_A_1_8) OR (FIREABLE(autorisation_A_1_9) OR (... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking a Boolean combination of formulas
lola: RUNNING
lola: subprocess 14 will run for 813 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: ! FIREABLE(liberation_A)
lola: ========================================
lola: SUBTASK
lola: checking initial satisfaction
lola: processed formula with 0 atomic propositions
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: RUNNING
lola: SUBRESULT
lola: result: yes
lola: The net satisfies the property already in its initial state.
lola: ========================================
lola: subprocess 15 will run for 1626 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: E(AG ((FIREABLE(autorisation_A_1_1) OR (FIREABLE(autorisation_A_1_2) OR (FIREABLE(autorisation_A_1_3) OR (FIREABLE(autorisation_A_1_4) OR (FIREABLE(autorisation_A_1_5) OR (FIREABLE(autorisation_A_1_6) OR (FIREABLE(autorisation_A_1_7) OR (FIREABLE(autorisation_A_1_8) OR (FIREABLE(autorisation_A_1_9) OR (FIREABLE(autorisation_A_1_10) OR (FIREABLE(autorisation_A_1_11) OR (FIREABLE(autorisation_A_1_12... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: E(!(E(TRUE U !((FIREABLE(autorisation_A_1_1) OR (FIREABLE(autorisation_A_1_2) OR (FIREABLE(autorisation_A_1_3) OR (FIREABLE(autorisation_A_1_4) OR (FIREABLE(autorisation_A_1_5) OR (FIREABLE(autorisation_A_1_6) OR (FIREABLE(autorisation_A_1_7) OR (FIREABLE(autorisation_A_1_8) OR (FIREABLE(autorisation_A_1_9) OR (FIREABLE(autorisation_A_1_10) OR (FIREABLE(autorisation_A_1_11) OR (FIREABLE(autorisati... (shortened)
lola: processed formula length: 37822
lola: 7756311 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 3 significant temporal operators and needs 13 bytes of payload
lola: SUBRESULT
lola: result: yes
lola: The net satisfies the given formula.
lola: SUBRESULT
lola: result: yes
lola: The Boolean predicate is true.
lola: ========================================
lola: ========================================
lola: subprocess 15 will run for 1226 seconds at most (--localtimelimit=0)
lola: ========================================
lola: ...considering subproblem: EG (EX (EX ((FIREABLE(autorisation_A_1_1) OR (FIREABLE(autorisation_A_1_2) OR (FIREABLE(autorisation_A_1_3) OR (FIREABLE(autorisation_A_1_4) OR (FIREABLE(autorisation_A_1_5) OR (FIREABLE(autorisation_A_1_6) OR (FIREABLE(autorisation_A_1_7) OR (FIREABLE(autorisation_A_1_8) OR (FIREABLE(autorisation_A_1_9) OR (FIREABLE(autorisation_A_1_10) OR (FIREABLE(autorisation_A_1_11) OR (FIREABLE(autorisation_... (shortened)
lola: ========================================
lola: SUBTASK
lola: checking CTL
lola: processed formula: !(A(TRUE U !(EX(EX((FIREABLE(autorisation_A_1_1) OR (FIREABLE(autorisation_A_1_2) OR (FIREABLE(autorisation_A_1_3) OR (FIREABLE(autorisation_A_1_4) OR (FIREABLE(autorisation_A_1_5) OR (FIREABLE(autorisation_A_1_6) OR (FIREABLE(autorisation_A_1_7) OR (FIREABLE(autorisation_A_1_8) OR (FIREABLE(autorisation_A_1_9) OR (FIREABLE(autorisation_A_1_10) OR (FIREABLE(autorisation_A_1_11) OR (FIREABLE(autori... (shortened)
lola: processed formula length: 1759
lola: 7756311 rewrites
lola: formula mentions 0 of 138 places; total mentions: 0
lola: closed formula file BridgeAndVehicles-COL-V50P20N20-CTLFireability.task
lola: STORE
lola: using a bit-perfect encoder (--encoder=bit)
lola: using 524 bytes per marking, with 0 unused bits
lola: using a prefix tree store (--store=prefix)
lola: RUNNING
lola: CTL formula contains 1 significant temporal operators and needs 5 bytes of payload
lola: SUBRESULT
lola: result: no
lola: The net does not satisfy the given formula.
lola: RESULT
lola: summary: yes unknown no no no no no yes no no no unknown unknown no yes no
lola: ========================================

BK_STOP 1464458101484

--------------------
content from stderr:

parsing of model.pnml complete

Sequence of Actions to be Executed by the VM

This is useful if one wants to reexecute the tool in the VM from the submitted image disk.

set -x
# this is for BenchKit: configuration of major elements for the test
export BK_INPUT="S_BridgeAndVehicles-PT-V50P20N20"
export BK_EXAMINATION="CTLFireability"
export BK_TOOL="lola"
export BK_RESULT_DIR="/users/gast00/fkordon/BK_RESULTS/OUTPUTS"
export BK_TIME_CONFINEMENT="3600"
export BK_MEMORY_CONFINEMENT="16384"

# this is specific to your benchmark or test

export BIN_DIR="$HOME/BenchKit/bin"

# remove the execution directoty if it exists (to avoid increse of .vmdk images)
if [ -d execution ] ; then
rm -rf execution
fi

tar xzf /home/mcc/BenchKit/INPUTS/S_BridgeAndVehicles-PT-V50P20N20.tgz
mv S_BridgeAndVehicles-PT-V50P20N20 execution

# this is for BenchKit: explicit launching of the test

cd execution
echo "====================================================================="
echo " Generated by BenchKit 2-2979"
echo " Executing tool lola"
echo " Input is S_BridgeAndVehicles-PT-V50P20N20, examination is CTLFireability"
echo " Time confinement is $BK_TIME_CONFINEMENT seconds"
echo " Memory confinement is 16384 MBytes"
echo " Number of cores is 4"
echo " Run identifier is r170kn-ebro-146433132800337"
echo "====================================================================="
echo
echo "--------------------"
echo "content from stdout:"
echo
echo "=== Data for post analysis generated by BenchKit (invocation template)"
echo
if [ "CTLFireability" = "UpperBounds" ] ; then
echo "The expected result is a vector of positive values"
echo NUM_VECTOR
elif [ "CTLFireability" != "StateSpace" ] ; then
echo "The expected result is a vector of booleans"
echo BOOL_VECTOR
else
echo "no data necessary for post analysis"
fi
echo
if [ -f "CTLFireability.txt" ] ; then
echo "here is the order used to build the result vector(from text file)"
for x in $(grep Property CTLFireability.txt | cut -d ' ' -f 2 | sort -u) ; do
echo "FORMULA_NAME $x"
done
elif [ -f "CTLFireability.xml" ] ; then # for cunf (txt files deleted;-)
echo echo "here is the order used to build the result vector(from xml file)"
for x in $(grep '' CTLFireability.xml | cut -d '>' -f 2 | cut -d '<' -f 1 | sort -u) ; do
echo "FORMULA_NAME $x"
done
fi
echo
echo "=== Now, execution of the tool begins"
echo
echo -n "BK_START "
date -u +%s%3N
echo
timeout -s 9 $BK_TIME_CONFINEMENT bash -c "/home/mcc/BenchKit/BenchKit_head.sh 2> STDERR ; echo ; echo -n \"BK_STOP \" ; date -u +%s%3N"
if [ $? -eq 137 ] ; then
echo
echo "BK_TIME_CONFINEMENT_REACHED"
fi
echo
echo "--------------------"
echo "content from stderr:"
echo
cat STDERR ;