About the Execution of ITS-Tools for CircularTrains-PT-012
Execution Summary | |||||
Max Memory Used (MB) |
Time wait (ms) | CPU Usage (ms) | I/O Wait (ms) | Computed Result | Execution Status |
352.300 | 5516.00 | 12918.00 | 141.90 | FFFTFFFTTTTTTFTT | normal |
Execution Chart
We display below the execution chart for this examination (boot time has been removed).
Trace from the execution
Waiting for the VM to be ready (probing ssh)
..................
=====================================================================
Generated by BenchKit 2-2265
Executing tool itstools
Input is CircularTrains-PT-012, examination is ReachabilityFireability
Time confinement is 3600 seconds
Memory confinement is 16384 MBytes
Number of cores is 4
Run identifier is r005kn-ebro-143214234300350
=====================================================================
--------------------
content from stdout:
=== Data for post analysis generated by BenchKit (invocation template)
The expected result is a vector of booleans
BOOL_VECTOR
here is the order used to build the result vector(from text file)
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-0
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-1
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-10
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-11
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-12
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-13
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-14
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-15
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-2
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-3
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-4
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-5
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-6
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-7
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-8
FORMULA_NAME CircularTrains-PT-012-ReachabilityFireability-9
=== Now, execution of the tool begins
BK_START 1432305155351
FORMULA CircularTrains-PT-012-ReachabilityFireability-14 FALSE TECHNIQUES TOPOLOGICAL
FORMULA CircularTrains-PT-012-ReachabilityFireability-13 FALSE TECHNIQUES TOPOLOGICAL
FORMULA CircularTrains-PT-012-ReachabilityFireability-12 FALSE TECHNIQUES TOPOLOGICAL
FORMULA CircularTrains-PT-012-ReachabilityFireability-11 TRUE TECHNIQUES TOPOLOGICAL
FORMULA CircularTrains-PT-012-ReachabilityFireability-7 FALSE TECHNIQUES TOPOLOGICAL
FORMULA CircularTrains-PT-012-ReachabilityFireability-5 TRUE TECHNIQUES TOPOLOGICAL
FORMULA CircularTrains-PT-012-ReachabilityFireability-4 TRUE TECHNIQUES TOPOLOGICAL
FORMULA CircularTrains-PT-012-ReachabilityFireability-1 FALSE TECHNIQUES TOPOLOGICAL
work folder: /home/mcc/execution
unsat
unsat
Invariant property CircularTrains-PT-012-ReachabilityFireability-0 does not hold.
FORMULA CircularTrains-PT-012-ReachabilityFireability-0 FALSE TECHNIQUES DECISION_DIAGRAMS TOPOLOGICAL COLLATERAL_PROCESSING
Reachability property CircularTrains-PT-012-ReachabilityFireability-2 is true.
FORMULA CircularTrains-PT-012-ReachabilityFireability-2 TRUE TECHNIQUES DECISION_DIAGRAMS TOPOLOGICAL COLLATERAL_PROCESSING
Reachability property CircularTrains-PT-012-ReachabilityFireability-3 is true.
FORMULA CircularTrains-PT-012-ReachabilityFireability-3 TRUE TECHNIQUES DECISION_DIAGRAMS TOPOLOGICAL COLLATERAL_PROCESSING
Reachability property CircularTrains-PT-012-ReachabilityFireability-6 is true.
FORMULA CircularTrains-PT-012-ReachabilityFireability-6 TRUE TECHNIQUES DECISION_DIAGRAMS TOPOLOGICAL COLLATERAL_PROCESSING
Reachability property CircularTrains-PT-012-ReachabilityFireability-8 is true.
FORMULA CircularTrains-PT-012-ReachabilityFireability-8 TRUE TECHNIQUES DECISION_DIAGRAMS TOPOLOGICAL COLLATERAL_PROCESSING
Reachability property CircularTrains-PT-012-ReachabilityFireability-9 is true.
FORMULA CircularTrains-PT-012-ReachabilityFireability-9 TRUE TECHNIQUES DECISION_DIAGRAMS TOPOLOGICAL COLLATERAL_PROCESSING
Invariant property CircularTrains-PT-012-ReachabilityFireability-10 does not hold.
FORMULA CircularTrains-PT-012-ReachabilityFireability-10 FALSE TECHNIQUES DECISION_DIAGRAMS TOPOLOGICAL COLLATERAL_PROCESSING
Reachability property CircularTrains-PT-012-ReachabilityFireability-15 is true.
FORMULA CircularTrains-PT-012-ReachabilityFireability-15 TRUE TECHNIQUES DECISION_DIAGRAMS TOPOLOGICAL COLLATERAL_PROCESSING
unsat
BK_STOP 1432305160867
--------------------
content from stderr:
Java HotSpot(TM) 64-Bit Server VM warning: ignoring option MaxPermSize=512m; support was removed in 8.0
May 22, 2015 2:32:39 PM fr.lip6.move.gal.application.Application transformPNML
INFO: Parsing pnml file : /home/mcc/execution/model.pnml
May 22, 2015 2:32:39 PM fr.lip6.move.gal.nupn.PTNetReader loadFromXML
INFO: Load time of PNML (sax parser for PT used): 33 ms
May 22, 2015 2:32:39 PM fr.lip6.move.gal.pnml.togal.PTGALTransformer handlePage
INFO: Transformed 24 places.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.pnml.togal.PTGALTransformer handlePage
INFO: Transformed 12 transitions.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Invariant property CircularTrains-PT-012-ReachabilityFireability-1 is trivially false : it is not verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Reachable property CircularTrains-PT-012-ReachabilityFireability-4 is trivially true : it is verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Reachable property CircularTrains-PT-012-ReachabilityFireability-5 is trivially true : it is verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Invariant property CircularTrains-PT-012-ReachabilityFireability-7 is trivially false : it is not verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Reachable property CircularTrains-PT-012-ReachabilityFireability-11 is trivially true : it is verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Invariant property CircularTrains-PT-012-ReachabilityFireability-12 is trivially false : it is not verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Invariant property CircularTrains-PT-012-ReachabilityFireability-13 is trivially false : it is not verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Invariant property CircularTrains-PT-012-ReachabilityFireability-14 is trivially false : it is not verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Invariant property CircularTrains-PT-012-ReachabilityFireability-1 is trivially false : it is not verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Reachable property CircularTrains-PT-012-ReachabilityFireability-4 is trivially true : it is verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Reachable property CircularTrains-PT-012-ReachabilityFireability-5 is trivially true : it is verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Invariant property CircularTrains-PT-012-ReachabilityFireability-7 is trivially false : it is not verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Reachable property CircularTrains-PT-012-ReachabilityFireability-11 is trivially true : it is verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Invariant property CircularTrains-PT-012-ReachabilityFireability-12 is trivially false : it is not verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Invariant property CircularTrains-PT-012-ReachabilityFireability-13 is trivially false : it is not verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.PropertySimplifier rewriteWithInitialState
INFO: Invariant property CircularTrains-PT-012-ReachabilityFireability-14 is trivially false : it is not verified in initial state.
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.GALRewriter flatten
INFO: Flatten gal took : 63 ms
May 22, 2015 2:32:39 PM fr.lip6.move.serialization.SerializationUtil systemToFile
INFO: Time to serialize gal into /home/mcc/execution/ReachabilityFireability.gal : 11 ms
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.GALRewriter flatten
INFO: Flatten gal took : 35 ms
May 22, 2015 2:32:39 PM fr.lip6.move.gal.instantiate.GALRewriter flatten
INFO: Flatten gal took : 42 ms
May 22, 2015 2:32:40 PM fr.lip6.move.gal.cegar.support.SupportManager computeSupport
INFO: For property CircularTrains-PT-012-ReachabilityFireability-0:[invariant] : ((Section_9>=1)&&(F10>=1)) found Support [Section_9, F10]
May 22, 2015 2:32:40 PM fr.lip6.move.gal.cegar.support.SupportManager computeSupport
INFO: Computing abstraction support, depth 0, found support 2
May 22, 2015 2:32:40 PM fr.lip6.move.gal.cegar.abstractor.BoundComputer compute
INFO: Bounding GAL to K = 1
May 22, 2015 2:32:40 PM fr.lip6.move.gal.cegar.abstractor.VariablesAbstractor abstractUsingSupport
INFO: Abstracting GAL, removed 22 / 24 variable(s)
May 22, 2015 2:32:40 PM fr.lip6.move.gal.cegar.checkers.CEGARChecker check
INFO: Checking abstraction for property CircularTrains-PT-012-ReachabilityFireability-0(refined 0 times)...
May 22, 2015 2:32:40 PM fr.lip6.move.gal.cegar.checkers.CEGARChecker check
INFO: Running its-reach -reachable on the abstraction...
May 22, 2015 2:32:40 PM fr.lip6.move.serialization.SerializationUtil systemToFile
INFO: No display to refresh.
May 22, 2015 2:32:40 PM fr.lip6.move.serialization.SerializationUtil serializePropertiesForITSTools
INFO: Time to serialize properties into /home/mcc/execution/ReachabilityFireability.prop : 1 ms
May 22, 2015 2:32:40 PM fr.lip6.move.gal.instantiate.GALRewriter flatten
INFO: Flatten gal took : 12 ms
May 22, 2015 2:32:40 PM fr.lip6.move.serialization.SerializationUtil systemToFile
INFO: Time to serialize gal into /home/mcc/execution/work/abstract.gal : 2 ms
May 22, 2015 2:32:40 PM fr.lip6.move.gal.gal2smt.Gal2SMTFrontEnd checkProperties
INFO: SMT solution for property CircularTrains-PT-012-ReachabilityFireability-0(UNSAT) depth K=1 took 364 ms
May 22, 2015 2:32:40 PM fr.lip6.move.gal.gal2smt.Gal2SMTFrontEnd checkProperties
INFO: SMT solution for property CircularTrains-PT-012-ReachabilityFireability-2(UNSAT) depth K=1 took 40 ms
May 22, 2015 2:32:40 PM fr.lip6.move.gal.cegar.checkers.ITSLauncher run
INFO: Run of its-reach took 378 ms
May 22, 2015 2:32:40 PM fr.lip6.move.gal.cegar.checkers.CEGARChecker check
INFO: Found trace: [t9_to_10]
May 22, 2015 2:32:40 PM fr.lip6.move.gal.cegar.checkers.CEGARChecker check
INFO: Running its-reach -trace [t9_to_10] on the original GAL...
May 22, 2015 2:32:40 PM fr.lip6.move.gal.gal2smt.Gal2SMTFrontEnd checkProperties
INFO: SMT solution for property CircularTrains-PT-012-ReachabilityFireability-3(UNSAT) depth K=1 took 40 ms
Exception in thread "Equinox Shutdown Hook" java.lang.IllegalStateException: Shutdown in progress
at java.io.DeleteOnExitHook.add(DeleteOnExitHook.java:60)
at java.io.File.deleteOnExit(File.java:1079)
at org.eclipse.osgi.storagemanager.StorageManager.initializeInstanceFile(StorageManager.java:188)
at org.eclipse.osgi.storagemanager.StorageManager.open(StorageManager.java:707)
at org.eclipse.osgi.storage.Storage.getChildStorageManager(Storage.java:1749)
at org.eclipse.osgi.storage.Storage.save0(Storage.java:1034)
at org.eclipse.osgi.storage.Storage.save(Storage.java:1009)
at org.eclipse.osgi.internal.framework.StorageSaver$StorageSaverTask.run(StorageSaver.java:28)
at java.lang.Thread.run(Thread.java:745)
Sequence of Actions to be Executed by the VM
This is useful if one wants to reexecute the tool in the VM from the submitted image disk.
set -x
# this is for BenchKit: configuration of major elements for the test
export BK_INPUT="CircularTrains-PT-012"
export BK_EXAMINATION="ReachabilityFireability"
export BK_TOOL="itstools"
export BK_RESULT_DIR="/users/gast00/fkordon/BK_RESULTS/OUTPUTS"
export BK_TIME_CONFINEMENT="3600"
export BK_MEMORY_CONFINEMENT="16384"
# this is specific to your benchmark or test
export BIN_DIR="$HOME/BenchKit/bin"
# remove the execution directoty if it exists (to avoid increse of .vmdk images)
if [ -d execution ] ; then
rm -rf execution
fi
tar xzf /home/mcc/BenchKit/INPUTS/CircularTrains-PT-012.tgz
mv CircularTrains-PT-012 execution
# this is for BenchKit: explicit launching of the test
cd execution
echo "====================================================================="
echo " Generated by BenchKit 2-2265"
echo " Executing tool itstools"
echo " Input is CircularTrains-PT-012, examination is ReachabilityFireability"
echo " Time confinement is $BK_TIME_CONFINEMENT seconds"
echo " Memory confinement is 16384 MBytes"
echo " Number of cores is 4"
echo " Run identifier is r005kn-ebro-143214234300350"
echo "====================================================================="
echo
echo "--------------------"
echo "content from stdout:"
echo
echo "=== Data for post analysis generated by BenchKit (invocation template)"
echo
if [ "ReachabilityFireability" = "ReachabilityComputeBounds" ] ; then
echo "The expected result is a vector of positive values"
echo NUM_VECTOR
elif [ "ReachabilityFireability" != "StateSpace" ] ; then
echo "The expected result is a vector of booleans"
echo BOOL_VECTOR
else
echo "no data necessary for post analysis"
fi
echo
if [ -f "ReachabilityFireability.txt" ] ; then
echo "here is the order used to build the result vector(from text file)"
for x in $(grep Property ReachabilityFireability.txt | cut -d ' ' -f 2 | sort -u) ; do
echo "FORMULA_NAME $x"
done
elif [ -f "ReachabilityFireability.xml" ] ; then # for cunf (txt files deleted;-)
echo echo "here is the order used to build the result vector(from xml file)"
for x in $(grep '
echo "FORMULA_NAME $x"
done
fi
echo
echo "=== Now, execution of the tool begins"
echo
echo -n "BK_START "
date -u +%s%3N
echo
timeout -s 9 $BK_TIME_CONFINEMENT bash -c "/home/mcc/BenchKit/BenchKit_head.sh 2> STDERR ; echo ; echo -n \"BK_STOP \" ; date -u +%s%3N"
if [ $? -eq 137 ] ; then
echo
echo "BK_TIME_CONFINEMENT_REACHED"
fi
echo
echo "--------------------"
echo "content from stderr:"
echo
cat STDERR ;